Extract beam maximum dead and live loads
Carlos Villegas
Hi, I am trying to export a csv or excel file where I can see the maximum Dead and Live/Roof live load moments in each beam. I need to obtain them unfactored to post-process them in excel. The table would simply have the beam label, Md and ML. I've been…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Composite beam with 2 deck types
Carlos Villegas
Hi, I am modelling a beam with a change of deck along the length of the beam (half of the beam has a W2+3.5" verco deck, and the other half has a W2+2" deck). I read this response: Effects of Changing Deck Type - RAM | STAAD | ADINA Wiki - RAM | STAAD…
Answered
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Customized curtailment provision in RCDC?
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Asv required for is greater than Asv provided.
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
RCDC is providing steel for beams in several layers of 12mm dia. for some Beams
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
What is the purpose of the Ignore Torsion feature available in RCDC Design setting?
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Is there a Customized curtailment provision in RCDC ?
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Does STAAD advanced concrete design (RCDC) consider the contributing effects of the slab flanges in RC beam design?
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Why is RCDC taking wind load shears to do ductile detailing for earthquake loads?
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
How the effective depth is calculated in beam design and what is the impact of “maximum Aggregate 2 Size” on effective depth?
Nidhi Valia
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
RCDC is considering 'Zero" bending moment at left and right support despite there being some Bending moment at the support.
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Serviceability check for allowable deflections as per ACI 318M-14
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
In BBS for ductile beams, there should be no lap splice within the joint and within 2D from the face of the column. (ACI 318M – 14 cl. 18.6.3.3)
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Clarification regarding the curtailment of 100% top reinforcement.
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Why RCDC is giving more reinforcement at bottom near supports as curtailed bars?
Sye
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
How to calculate reinforcement of beam at face of column in RCDC?
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Sway Shear Calculation for Ductile Beam Design
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
How to make beams pass if failed due to shear stress exceeds maximum permissible shear stress (TauC)?
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
7 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Dummy beam
Sulaiman Ade
Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
Answered
over 2 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
How does STAAD determine beam deflections?
Pascual Mauricio
Hello, I am modeling a floor slab (1 ft thick) with concrete beams (all 24" wide x 36" deep). These beams will be cast monolithically with the floor slab, therefore the beams are modeled as 24" deep. My question is how does STAAD determine the following…
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Can I Reduce Development length of bars in the beam by using RCDC
Sulaiman Ade
Hello Everyone How can I reduce the development length bars in the beam (Figure 1-1), I'm running to get a result like this beam (figure 2-1) Figure 1-1 Figure 2-1
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Yield Strength Rounds Down
Dmitri Babisin
Why does RAM Structural System round down the Yield Strength fy value? I am located in Canada so if I use american steel then I convert the fy=50 000psi to MPa which is approximately 345MPa. So in the Modeler when laying out the beams I type in 345MPa…
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Design of composite (Steel beam+deck slab) as per AISC, BS & Eurocode
ArunStr
Dear bentley & friends, I had modeled the floor beams as composite and gave design parameter for Eurocode but design not performed and I had changed the code to BS and AISC, in this two codes composite design is done but not in eurocode. Why? How…
over 9 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RAM Beam Designing Composite Decks to Different Minimum Composite Action Criteria
Jon Tai
I was wondering if there was a way to design girders with a different minimum composite action than my joists. Currently I have the minimum set at 25% for all beams but I want the girders to be designed for a minimum of 50%. Is there a way in RAM to set…
Answered
over 9 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum