Beam design with axial force and Biaxial Moment - Side face reinforcement for Column detailing
Ranjana Shinde
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original…
23 days ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
RAM Concept: As (after reduction for development length)
Bowen Shen
I am working on one-way slab supported by mild reinforced concrete beams. The beam is trimmed as a T-section with flange width of 99". I drew #4 at 18" (full slab area) on top of the slab in the direction parallel to the beam, which make 5-#4 (total As…
1 month ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Axial force on non-PT mild reinforced beams under dead and live load cases
Bowen Shen
I am modeling a one-way concrete slab. PT girders are in perimeter and in the north-south direction, and mild reinforced infill concrete beam in the east-west direction. When I checked mild reinforced concrete design, I noticed the cross-section at end…
2 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
SCBF's Beam design using RAM Structural System
Katy Briggs
Hi I am designing a steel building using SCBF's and I was wondering if there is any procedure or way to check the beams inside RAM at the SCBF's per the seismic provisions (ASCE 341-10 Section F2.3(i) and (ii)) ? I know RAM checks for the required column…
2 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Extract beam maximum dead and live loads
Carlos Villegas
Hi, I am trying to export a csv or excel file where I can see the maximum Dead and Live/Roof live load moments in each beam. I need to obtain them unfactored to post-process them in excel. The table would simply have the beam label, Md and ML. I've been…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Unknown Unreducible DL being applied to beams
Ryan Hollenbeck
I have a location where two deck types meet, one with a roof loading and the other with a floor loading. There is an odd line load being applied in the analysis that is greatly affecting the design on my beams and columns. I cannot see to find the source…
Answered
3 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Composite beam with 2 deck types
Carlos Villegas
Hi, I am modelling a beam with a change of deck along the length of the beam (half of the beam has a W2+3.5" verco deck, and the other half has a W2+2" deck). I read this response: Effects of Changing Deck Type - RAM | STAAD | ADINA Wiki - RAM | STAAD…
Answered
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Beam failure in RCDC
NAUSHAD KHAN
Hey I am also getting the same problem as a new beginner I didn't understood the offset removing answer ( communities.bentley.com/.../staad-rcdc---beam-bm-detailing-failure) how do I remove offset I have already created mesh and now every beam got divided…
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
BEAMS ARE NOT LOADING IN RCDC
NAUSHAD KHAN
I Have created a model in staadpro and analyzed it and I also used mesh tool for slab design now after creating mesh the beams are divided into small length ..... no problem till now but when I import this model in RCDC the beams are not loading (i think…
4 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Beam Design for Biaxial Moment
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Abhisek Mandal…
5 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Sway Shear Calculation in STAAD
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
RAM Concrete Beam Design - Design Warning for Flexural Reinforcement
Jared Warren
I have an 8"x16" concrete beam and in the end span of a multi-span condition, it says the bottom flexural beam reinforcement fails code limit by 1 bar. I have 2-#5 bars currently for all spans and for every other span, this is adequate and meets all code…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
How do I get around the RCDC's mandatory three bars?
Rahul Brijpuriya
While design beam RCDC provide min 3 no of bars in the moment area how to bypass this check .There should be option in the RCDC to consider or not to consider this clause ?
9 months ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Detailing of beams with different depths in RCDC
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original…
9 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Include torsion in beam design as per IS456
Modestas
Applies To Product(s): STAAD Advanced Concrete Design Version(s): All Environment: N/A Area: Concrete Design Subarea: IS 456:2000 Original Author: Abhisek Mandal Bentley…
5 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Why IS Code 800-2007 LSD fails Ratio INFINITY, while AISC 360-10 ASD passed Beam with Ratio 0.44? Taper beam
Arun Chugh
1) Design check by IS Code 800-2007 LSD fails gives result of Bending Ratio = “INFINITY”, which passes with AISC 360-10 ASD Ratio 0.44! Also IS 800 code output does not give any ratio in both major, minor axis! 2) Is this 12 mm Flange thickness is critical…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
DEPTH OF BEAM SHALL PREFERABLY BE LESS THAN THE 1/4TH OF CLEAR SPAN
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
WARNING BEAM CODE RECOMMENDS THAT WIDTH/DEPTH > 0.3
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
How to get the max and min forces in each member ?
Lt.Col. Parmar
How to get the max and min forces in each member ? Not to get the max of a selected group. need to get the maxm forces of each members (beams/column)
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RAM Elements existing PEMB analysis always fails
Jack Worline
We often need to analyze existing PEMB structures and when only existing loads are applied the structure still fails. We have used the MBMA special considerations option in our design and that does not seem to help. What are we missing? Is there another…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
hello everyone
Sushant Kumar
hello everyone,i am getting warning, can anyone help me out in removing those warning. warning are- 1.WARNING:Section fails while detailing 2.WARNING:Section fails while designing section: 3. WARNING:Reinforcement % exceeds maximum limit
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Does RCDC calculates moment capacity for sway shear calculations as per rectangular section or flanged section for beam?
DSANJU
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original Author: SANJIB DAS…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Uplift point loads in my model are not being considered by the ram beam design module
Kyle Gerard
I have a building with screen wall loads on the roof. These loads act as a couple with the main post and the kicker having reactions in opposite directions. When I add these loads to the ram model, ram beam module is only considering the downward gravity…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Customized curtailment provision in RCDC?
Abhisek M
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Asv required for is greater than Asv provided.
Aaradhya Rahate
Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
>