  • Beam design with axial force and Biaxial Moment - Side face reinforcement for Column detailing

    ​​ Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original…
  • RAM Concept: As (after reduction for development length)

    I am working on one-way slab supported by mild reinforced concrete beams. The beam is trimmed as a T-section with flange width of 99". I drew #4 at 18" (full slab area) on top of the slab in the direction parallel to the beam, which make 5-#4 (total As…
  • Axial force on non-PT mild reinforced beams under dead and live load cases

    I am modeling a one-way concrete slab. PT girders are in perimeter and in the north-south direction, and mild reinforced infill concrete beam in the east-west direction. When I checked mild reinforced concrete design, I noticed the cross-section at end…
  • SCBF's Beam design using RAM Structural System

    Hi I am designing a steel building using SCBF's and I was wondering if there is any procedure or way to check the beams inside RAM at the SCBF's per the seismic provisions (ASCE 341-10 Section F2.3(i) and (ii)) ? I know RAM checks for the required column…
  • Extract beam maximum dead and live loads

    Hi, I am trying to export a csv or excel file where I can see the maximum Dead and Live/Roof live load moments in each beam. I need to obtain them unfactored to post-process them in excel. The table would simply have the beam label, Md and ML. I've been…
  • Unknown Unreducible DL being applied to beams

    I have a location where two deck types meet, one with a roof loading and the other with a floor loading. There is an odd line load being applied in the analysis that is greatly affecting the design on my beams and columns. I cannot see to find the source…
  • Composite beam with 2 deck types

    Hi, I am modelling a beam with a change of deck along the length of the beam (half of the beam has a W2+3.5" verco deck, and the other half has a W2+2" deck). I read this response: Effects of Changing Deck Type - RAM | STAAD | ADINA Wiki - RAM | STAAD…
  • Beam failure in RCDC

    Hey I am also getting the same problem as a new beginner I didn't understood the offset removing answer ( communities.bentley.com/.../staad-rcdc---beam-bm-detailing-failure) how do I remove offset I have already created mesh and now every beam got divided…
  • BEAMS ARE NOT LOADING IN RCDC

    I Have created a model in staadpro and analyzed it and I also used mesh tool for slab design now after creating mesh the beams are divided into small length ..... no problem till now but when I import this model in RCDC the beams are not loading (i think…
  • Beam Design for Biaxial Moment

    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Abhisek Mandal…
  • Sway Shear Calculation in STAAD

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
  • RAM Concrete Beam Design - Design Warning for Flexural Reinforcement

    I have an 8"x16" concrete beam and in the end span of a multi-span condition, it says the bottom flexural beam reinforcement fails code limit by 1 bar. I have 2-#5 bars currently for all spans and for every other span, this is adequate and meets all code…
  • How do I get around the RCDC's mandatory three bars?

    While design beam RCDC provide min 3 no of bars in the moment area how to bypass this check .There should be option in the RCDC to consider or not to consider this clause ?
  • Detailing of beams with different depths in RCDC

    ​​ Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original…
  • Include torsion in beam design as per IS456

    Applies To Product(s): STAAD Advanced Concrete Design Version(s): All Environment: N/A Area: Concrete Design Subarea: IS 456:2000 Original Author: Abhisek Mandal Bentley…
  • Why IS Code 800-2007 LSD fails Ratio INFINITY, while AISC 360-10 ASD passed Beam with Ratio 0.44? Taper beam

    1) Design check by IS Code 800-2007 LSD fails gives result of Bending Ratio = “INFINITY”, which passes with AISC 360-10 ASD Ratio 0.44! Also IS 800 code output does not give any ratio in both major, minor axis! 2) Is this 12 mm Flange thickness is critical…
  • DEPTH OF BEAM SHALL PREFERABLY BE LESS THAN THE 1/4TH OF CLEAR SPAN

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
  • WARNING BEAM CODE RECOMMENDS THAT WIDTH/DEPTH > 0.3

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Design Subarea: Concrete Design Is13920 Original Author: Abhisek Mandal, Bentley Technical Support…
  • How to get the max and min forces in each member ?

    How to get the max and min forces in each member ? Not to get the max of a selected group. need to get the maxm forces of each members (beams/column)
  • RAM Elements existing PEMB analysis always fails

    We often need to analyze existing PEMB structures and when only existing loads are applied the structure still fails. We have used the MBMA special considerations option in our design and that does not seem to help. What are we missing? Is there another…
  • hello everyone

    hello everyone,i am getting warning, can anyone help me out in removing those warning. warning are- 1.WARNING:Section fails while detailing 2.WARNING:Section fails while designing section: 3. WARNING:Reinforcement % exceeds maximum limit
  • Does RCDC calculates moment capacity for sway shear calculations as per rectangular section or flanged section for beam?

    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam design Original Author: SANJIB DAS…
  • Uplift point loads in my model are not being considered by the ram beam design module

    I have a building with screen wall loads on the roof. These loads act as a couple with the main post and the kicker having reactions in opposite directions. When I add these loads to the ram model, ram beam module is only considering the downward gravity…
  • Customized curtailment provision in RCDC?

    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…
  • Asv required for is greater than Asv provided.

    Applies To Product(s): STAAD Advanced Concrete Design Version(s): Connect Edition Environment: Area: Concrete Design Subarea: Beam Design Original Author: Aaradhya Rahate…