Browse By Tags

  • *** ERROR *** ABOVE COMMAND IS NOT RECOGNIZED. LINE IGNORED. anyone plz help me

    *** ERROR *** ABOVE COMMAND IS NOT RECOGNIZED. LINE IGNORED. i cant understand
  • Section Properties Not displaying in Report In Stadd Connect

    Hello Everyone ! I Have Done Analysis For Window Model Using Prismatic General Section. But While Generating Report , No Property Values i.e. Ixx, Iyy, Izz For Prismatic Section Were Displayed in Utilization Ratio Table. Please Suggest How to get…
  • WARNING- THE AXIAL COMPRESSIVE STRESS EXCEEDS THE EULER STRESS FORMEMBER

    Dear team, I am getting an error, for that I am attaching the model Steel Bldg.std please check & let me know how I can resolved this issue. And what are the things I need to keep on when I designs to avoid these types of errors. Kind regards…
  • The analysis of a stepped column is possible or not?

    PDF Dear communities, Please provide me the solution or method to design & analysis the STEPPED column. For the reference, I have attached the pdf file, please check it & provide me the solution. Thank you.
  • RCDC Design Calculation Print

    Hi Good day! I am having a problem with the printing of my Design Calculation Report, when it is already generating the design calculation report an error message pops out. See attached. Error Translation: >> Microsoft.NET Framework An…
  • Structural Design as per IS 13920 in staad.

    Hello sir(s), While deigning structure in staad as per IS 13920 i got following Note in output. NOTE :- SOME OF THE BEAMS CONNECTED TO THE COLUMN NO. ** ARE NOT DESIGNED. ONLY SHEAR FORCE FROM ANALYSIS WILL BE CONSIDERED FOR SHEAR DESIGN. Please…
  • Design of Solid slab (Conventional slabs)

    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
  • Dummy beam

    Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
  • RCDC Detailing Failure

    How to rectify this failure known as 'Detailing failure' in RCDC
  • How to Model complex Concrete building projects ?

    What is the easiest and accurate way to modeling complex and huge Concrete building projects, Including irregular elements and the shear wall? Can I model staad building planner?
  • Nodal Displacement and Member displacement and its allowable as per BS5950

    I have modelled one simple structure in STAAD PRO and found that there are two types of displacement value in post processing. NODE and MEMBER. Which displacement shall i use for comparing with allowable displacement as per BS5950 code.
  • How to simulate a building collapse on a staad pro structural design sofware.

    Please, i need your help, pls how can i simulate a building collapse on STAAD pro software, i am currently investigating the collapse mechanism of a structure and i am finding it difficult to simulate the progressive collapse using STAAD sofware, thank…
  • RC COLUMN DESIGN OUTPUT IN STAAD.Pro CONNECT Edition

    Hello, I´m currently reviewing a Reinforced Building Design in STAAD.Pro CONNECT Edition and The Client asked for some information; more specifically, the Design Moments and Axial Forces for the RC Columns, so I went to look up the info in the Analysis…
  • EXCEL VBA FOR PLATE CORNER FORCES

    Hello, I wanted an excel VBA programme by which i can get the plate corner moments/stresses for a particular group of plates. If anyone could share an excel with VBA code then it will be helpful as it saves lot of time.
  • Application of Temperature load in STAAD Pro

    Hi, Need some review on my understanding for a query "Application of Temp Load in STAAD Pro", From my observation in this community's discussion for apply of temp load, the three values will be require for input cell in staad. Here are Input details…
  • UC Ratio problem

    warehouse.zip wind calculation also in that folder.... try to fix this probem guys
  • how to get the loadings details in report????

    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
  • mast tower staad.pro v8i

    pl lead me to STAAD PROBLEM EXAMPLE for a mast. Been to a STAAD training & seen an example problem in the handout, but no leads to it. i WOULIKE LIKE TO RUN THAT MODEL & LEARN ITS STRUCTURAL ANALY. & steel DESIGN TO Eurocode checks
  • Design Parameters

    Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Import Export Solutions Subarea: Import/Export Original Author: Jason Chickneas Bentley Technical…
  • mast tower staad.pro v8i

    pl lead me to STAAD PROBLEM EXAMPLE for a mast. Been to a STAAD training & seen an example problem in the handout, but no leads to it. i WOULIKE LIKE TO RUN THAT MODEL & LEARN ITS STRUCTURAL ANALY. & steel DESIGN TO Eurocode checks
  • Tension Only member with initial axial capacity

    Hello to all, In reality horizontal braces (or vertical brace, beam, etc) that is design for tension only resist "some" axial compression capacity. Is there a way that this axial compression capacity can be input in STAAD? For example, a horizontal…