Browse By Tags

  • evento transitorio spegnimento pompa velocità variabile

    buonasera, ho riscontrato due errori in questa simulazione: 1) problema cavitazione 2) analizzando i risultati dell'analisi ho notato che le portate (flow) delle tubazioni a valle della pompa spenta non tendono mai a 0 ho pensato: per risolvere…
  • Error importing .dae file

    Hello, Whenever I'm importing a .dae file, I get an error message saying that Synchro can't read the .dae file and quits the process. It doesn't seem to be an issue with the file itself since other people have been able to open it on a different computer…
  • Extracting cracks in rigid concrete pavement

    Hello all. I am having trouble locating rigid concrete pavement deficiencies in my point cloud. I am only able to identify roughly 90% of cracks in my concrete that I can see from my imagery. I am using OpenRoads designer to analyze my point cloud.…
  • ContextCapture建立的实景模型可以导入SketchUp

    老师,你好! 请问ContextCapture建立的实景模型可以导入SketchUp软件,以供 SketchUp软件使用吗?ContextCapture创建的一个比较大的实景模型,输出何种文件格式才能方便SketchUp软件使用?有哪些可行的方案,具体流程是怎样的?
  • Could not open the default project. need help urgently

  • [connect update 15 c++] bmake fail to compile and return error

    Exception 0xe0434352 bmake: call truce I have checked my .net and visual studio installation. I could not figure out why, it worked fine on another computer. Below is my dump file Dump Summary.docx
  • Running 2 pumps in parallel

    Good Morning Everyone, I am a bit new to WaterCAD. I am trying to model 2 lift station pumps with different curves running parallel and joining together before tie in into a Force main. The model is attached. I am not sure how much data to input…
  • Problem displaying item name. Bentley Fiber

    Hi, Initially, when naming a fibernode element, there are no drawbacks. Even after making ´´Post´´ After applying ´´Merged to parent´´ and consulting the element from a new workspace, I find the following error when displaying the name: in the…
  • How to insert or modify the terrain points?

    Dear community, Could you please tell me that, how I can be able to insert a new point or modify the exiting point in a terrain model? Actually I would like to know that how it will be possible in CSV file and as well as in exiting terrain ( given by…
  • facing some challenges while using Open Road designer

    Mentioning the challenges here with: 1. How to change certain locations/ alignment at ground level by taking reference of x,y, or chainage? 2. How to change the centerline? 3. How to maintain or design an exact certain level /ground level…
  • CC

  • STEEL ROD AS BRACING IN STAAD PRO CONNECT EDITION

    I have model my truss and i want to add steel rod of 20mm diameter as a bracing on pipes carrying the truss,is this option available in Staad Pro Connect Edition?
  • 3D STEEL TRUSS DESIGN

    I want to design this kind of steel truss in Staad Pro Connect Edition, should i run analysis in staad space or staad plane which one is correct?
  • LINE LOAD ON ANALYTICAL MODEL STAAD PRO CONNECT EDITION

    Addition of partition wall load on slab should be added on analytical model in Staad Pro Connect Edition
  • PROJECT OF FLAT SLAB, WITHOUT BEAMS STAAD PRO CONNECT EDITION

    Option for modelling,analysis and design of a project with flat slab should be added in Staad Pro Connect Edition
  • CANTILEVER SLAB IN RCDC

    Design of cantilever slab in RCDC should be added and also slab supported by beams on its two sides and its other two sides free or only three sides are supported by beams and the other side free.
  • DEFLECTION CHECK OF RCC PLATES (RAMP)

    Iam designing a reinforced concrete ramp as a plate,the difficult iam facing is there is no BS 8110 in analytical design,and with the available BS 8007 i cant check deflection of the plate.
  • 5. What to do with after receiving a recently purchased CSS (Cloud Service Subscription) document, for AutoPIPE?

    This document contains key pieces of information for licensing any Bentley software not just AutoPIPE . 1. CSS number 2. Invoice Number and Date 3. Customer number 4. Remittance information CSS is a program where you pay Bentley in advance…
  • BS 8110

    BS 8110 should be added currently is not available in design at analytical modeling ,the BS available for concrete is only BS 8007.
  • ADDITION OF LINE LOAD ON PLATE

    Option for adding wall load (partition wall) as line load direct on slab should be added
  • RCDC ERROR WHILE DESIGNING BEAM (STAAD PRO CONNECT EDITION UPDATE 5)

    During design of beam in rcdc,if i put a check of crack width the software will not design and it gives a message written "Cannot find column [StAstTop] but if i dont check for crack width the software works perfectly.Need a help on this problem because…
  • RCDC ERROR WHILE DESIGNING BEAM (STAAD PRO CONNECT EDITION UPDATE 5)

    During design of beam in rcdc,if i put a check of crack width the software will not design and it gives a message written "Cannot find column [StAstTop] but if i dont check for crack width the software works perfectly.Need a help on this problem because…
  • Help with Projectwise Interplot Organizer Error: "OPENERR, Cannot open input file - No such file or directory"

    One of my users created an *.ips file that will not open in Projectwise Interplot Organizer giving the following error message (file copied from off our network to my desktop) "OPENERR, Cannot open input file C:\Users\williamsae\Desktop\test.ips - No…
  • CONCRETE GRADE SELECTION IN RCDC

    I think it will be better during design in RCDC,to select the concrete grade of column separately from that of wall.Concrete grade should be divided into two parts one for columns and the other one for walls.
  • PARAMETRIC WALL FOUNDATION DESIGN

    May you please improve the design of foundation of parametric wall in RCDC,lets say if i want my footing size to be 1500mm by 300mm depth,but the left side i want it to be 400mm from centre of wall and right side to be 1100mm from centre of wall,currently…