RE: Very slow tools: View Attributes and Color Table
Marc Thomas
Hi Christophe, ABD is more demanding of the network so I strongly reccommend increasing the speed (everything else will benefit too!). Connection all your PC's via a cheap 8 or 16-port unmanaged network switch, for example the HP J9559A, will make a…
over 6 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
RE: Unable to Create a Drawing/Sheet Model
Marc Thomas
Hi Nathan, Please can I suggest that you download Bentley Configuration Explorer and run it on your system. Once installed, click on Home tab > Process Configuration. Pick the appropriate Application, user and Project, then click Process. Once…
over 6 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
RE: most complete metric dataset
Marc Thomas
Hi Arturo, That help document is now out of date and is not delivered with ABD SS6. In NM datasets up to SS6 we delivered two project templates, NM_Full and NM_Light. NM_Light was configured to ignore the files contained in 'extendedcontent', NM_Full…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
RE: ABD SS6 - Network computer configuration
Marc Thomas
To add to Steve's comments I highly recommend SSDs to anyone for both new and existing workstations, I have upgraded both my Bentley machine and a couple of personal machines over the last couple of years, the performance improvement all round is very…
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
RE: dgnlibs in SS6
Marc Thomas
Hi Danny, The AECOsim Building Designer specific dgnlibs as delivered are in either the regional dataset: e.g.: C:\ProgramData\Bentley\AECOsimBuildingDesigner V8i Ss6\WorkSpace\BuildingDatasets\Dataset_GB\dgnlib or the project dataset: e.g.: C…
over 8 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
RE: ABD SS6 Company/Project Dataset filter
Marc Thomas
ABD SS6 - Adding Company Dataset Folders contains advice about setting up separate company dataset folders for non-ProjectWise installations. Unfortunately I have not tested this in ProjectWise myself so can't offer immediate guidance on implementing…
over 8 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
ABD SS6 - Adding Company Dataset Folders
Marc Thomas
One of the joys of ABD SS6 is the updated DataGroup interface where you can choose to locate new or copied items in Company or Project locations. Out of the box, new or copied Company items are put in their own files in the delivered dataset in C…
over 8 years ago
Peer Blogs
Looking under the bonnet...
ABD SS6 - QuickConfig
Marc Thomas
QuickConfig Standard deploys a simple AECOsim Building Designer SS6 network configuration for immediate use or as a template for testing and/or further customisation. In brief run the: first batch file to set up the workspace and a test project…
over 8 years ago
Peer Blogs
Looking under the bonnet...
ABD SS6 QuickConfig Standard - Deployment Files
Marc Thomas
Deployment and template files for AECOsim Building Designer SS6 - QuickConfig Standard. A deployment guide and full description are in ABD_SS6_QuickConfig.pdf alongside. QuickConfig deploys a simple AECOsim Building Designer SS6 network configuration…
ABD_SS6_QuickConfig_Standard.zip
over 8 years ago
Peer Blogs
Peer Blogs Gallery
PDF
ABD SS6 QuickConfig Standard - Deployment Guide
Marc Thomas
Deployment guide and full description for AECOsim Building Designer SS6 - QuickConfig Standard. Deployment and template files are in ABD_SS6_QuickConfig.zip alongside. QuickConfig deploys a simple AECOsim Building Designer SS6 network configuration…
ABD_SS6_QuickConfig.pdf
View
Hide
over 8 years ago
Peer Blogs
Peer Blogs Gallery
ABD SS6 - Best Practices - Cached Visible Edges
Marc Thomas
Why Cache? the reasons for using cached visible edges include: Freeze designs In a conventional MicroStation environment sheet files and their source Drawing Models are continually updated as references are modified. Bentley users have become used…
over 8 years ago
Peer Blogs
Looking under the bonnet...
Notepad++ Bentley CFG Schema - Yellow
Marc Thomas
This is the file linked from Making Configuration Files Legible in Notepad++, with the parchment (yellow) background version shown in the illustrations. Updated 12 September 2016
NotepadPlusPlusLanguage_BentleyConfig_YellowBackground.xml
View
Hide
over 8 years ago
Peer Blogs
Peer Blogs Gallery
Notepad++ Bentley CFG Schema - White
Marc Thomas
This is the file linked from Making Configuration Files Legible in Notepad++, the white background version. Updated 12 September 2016
NotepadPlusPlusLanguage_BentleyConfig_WhiteBackground.xml
View
Hide
over 8 years ago
Peer Blogs
Peer Blogs Gallery
%if exists expressions in .pcf files
James Manfield
I am trying to create an expression in a .pcf file which looks to see if a folder exists and if it does, sets the project data variable to it. If it fails to find the folder, th eproject data variable should be set to another folder. I am using the…
over 8 years ago
Product Administration
Product Administration Forum
MicroStation - QuickConfig Standard
Marc Thomas
QuickConfig Standard deploys a simple MicroStation SS3 or SS4 network configuration for immediate use or as a template for testing and/or further customisation. In brief run the: first batch file to set up the workspace and a test project second…
over 9 years ago
Peer Blogs
Looking under the bonnet...
AECOsim Building Designer - QuickConfig Standard
Marc Thomas
QuickConfig Standard deploys a simple AECOsim Building Designer SS5 network configuration for immediate use or as a template for testing and/or further customisation. In brief run the: first batch file to set up the workspace and a test project…
over 9 years ago
Peer Blogs
Looking under the bonnet...
AECOsim Building Designer - MicroStation Mode
Marc Thomas
Applies To Product(s): AECOsim Building Designer V8i Version(s): 08.11.09.593 and above Environment: N/A Area: General Subarea: Original Author: Marc Thomas …
over 7 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Configuring AECOsim Building Designer V8i - Index to posts
Marc Thomas
Note added 11 August 2018. For advice regarding CONNECT Edition, please see CONNECT Edition - Configuration : Customization Guides . Updated 11 August 2014. For convenience here is a list of my posts about configuring AECOsim Building Designer V8i…
over 9 years ago
Peer Blogs
Looking under the bonnet...
Configuring AECOsim Building Designer #7 – Sharing Standards
Marc Thomas
Anyone who has used a well managed MicroStation system will be familiar with the sharing of CAD standards via a networked workspace. So far I have moved to the network: project data. project and user configurations. the Company dataset…
over 9 years ago
Peer Blogs
Looking under the bonnet...
Configuring AECOsim Building Designer #6 – Roaming Users
Marc Thomas
The next step in networking AECOsim Building Designer is making an individual's user preferences accessible from any machine that they log onto. If your Windows system has implemented Roaming Profiles the user preferences can be stored there, the techniques…
over 9 years ago
Peer Blogs
Looking under the bonnet...
RE: Named Expressions - Want to Show and Hide Menus Based upon Starting Characters of Active File Name
Marc Thomas
Another example: I have a custom menu that includes some AECOsim tools that I don't want to see when I use the menu in either ABD's MicroStation Mode or vanilla MicroStation. ABD has a whole set of Named Expressions prefixed BD_. They don't appear…
over 9 years ago
Product Administration
Product Administration Forum
Configuring AECOsim Building Designer #4 – Redirecting to the Network
Marc Thomas
Updated 11 August 2014. There are a number of ways to redirect AECOsim (and MicroStation) to the network. The most common is to modify the mslocal.cfg file found in C:\Program Files (x86)\Bentley\AECOsimBuildingDesigner V8i Ss4\AECOsimBuildingDesigner…
over 9 years ago
Peer Blogs
Looking under the bonnet...
Configuring AECOsim Building Designer #1 - A Simple Test Project
Marc Thomas
This blog was written for AECOsim Building Designer SS4, it may still offer some insight, but related information in later articles will take precedence. 30 May 2019. For learning purposes without the complication of working with whatever existing project…
over 9 years ago
Peer Blogs
Looking under the bonnet...
Configuring AECOsim Building Designer #3 – Put a Company Dataset on the network
Marc Thomas
Updated 11 August 2014. From adding the Company Dataset in part 2 it is a short step to share the Company Dataset on the network. Steps: 1. Continuing from part 2, copy the Dataset_ Company folder from C:\ProgramData\Bentley\AECOsimBuildingDesigner…
over 9 years ago
Peer Blogs
Looking under the bonnet...
Configuring AECOsim Building Designer #5 – Putting Projects on the network
Marc Thomas
In part 3 I put the Company dataset on the network. However you will have noticed that the COMP_DATASET = E:/Dataset_Company_OnNetwork/ variable pointing to the network is contained in the Project Configuration File (PCF) on the C drive located in C:…
over 9 years ago
Peer Blogs
Looking under the bonnet...
<
>