Browse By Tags

  • OpenBuildings Designer - Clash Detection for Duplicate Elements

    Clash Detection Tool can be used not only to find clashes between different levels, files and disciplines, but also within one file as a Self-Check and to detect duplicate elements. To perform a Self-Check: Go to Collaborate tab -> Clash Detection…
  • Create userlist from template

    Hi, Is there a way to create a userlist from another one? Let's say i have a userlist name prov_serv, i want to create an other who is identical to prov_serv but with a different name in powershell. Is it possible?
  • Duplicate geometry in Physical modeller Staad Pro

    Hello sirs! Im recently started to learn Staad Pro and i want to know if im going to ignore duplicated nodes while in the Physical Modeller or is there a button or somewhere i can just delete those nodes? When i run the validate check i get the warnings…
  • How to isolate overlapping nodes (with duplicate coordinates X and Y)

    There are a few ways to isolate overlapping nodes with Voyager. One example is provided below, where the first Network program outputs the node table defining rounded values of X and Y with a certain tolerance (imposed in the script). The second…
  • How to check modelling error in Structure

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Geometry Original Author: Abhisek Mandal, Bentley Technical Support…
  • Copying multiple elements creates duplicates.

    Hi, as the title indicates I have an issue where copying more than one element results in duplicates being pasted. This issue does not occur when copying only one element at a time, I have checked that the existing elements are not already duplicated…
  • Structural Objects inserted twice

    Product(s): ProStructures, ProSteel & ProConcrete Version(s): CONNECT Edition (10.XX.00.XX) Environment: N/A Area: Modelling Subarea: Structural Objects Original Author: Alistair Lobo, Bentley Product Advantage…
  • Duplicate text appears when drawing is opened with Microstation V8i SELECTseries 4, but not when the drawing is opened with InRoads Survey.

    After creating a surface for a drawing in InRoads, when returning to the topo drawing in SS4 almost all of the text appears duplicated and unrotated. Can anyone help explain what is causing this error and provide any insight into resolving it?
  • Option Duplicate in Sacs 5.7

    Hello How can I copy members in a plan for another plan? Duplicate and Miror members option in sacs 5.7 Where is it located?
  • Reference numbers on Failure Modes

    Product(s): APM Implementation and Performance Management Version(s): All versions Environment: N\A Area: N/A Subarea: N\A Problem Failure Mode Reference numbers on Strategy Analysis are…
  • Copying properties of existing elements using Prototypes

    Product(s): WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): V8i, CONNECT Edition Area: Modeling Background This article explains how to use the Prototypes feature to copy properties of one…
  • Using the WHERE clause and Duplicate option in ModelBuilder to filter imported data

    Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): V8i, CONNECT Edition Area: Layout and Data Input Original Author: Scott Kampa, Bentley Technical…
  • Duplicating Controls - One control is changed in the controls tab and it changes another control.

    Product(s): Bentley WaterGEMS, WaterCAD, SewerCAD Version(s): V8i, Connect Edition Area: Layout and Data Input Problem One control is changed in the controls tab and it changes another control Can you duplicate controls…
  • "{SERVICE_IS_RELATED_TO_EQUIPMENT(VG.0000003279)} belongs to the ECSchema {ECSchema: PlantProjectSchema.01.04} which is not supported in this connection" Error on Synchronizing from Database to Drawing

    Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Installation-Configuration Subarea: Database Original Author: Harpreet…
  • Duplicate Key Tags Message in OpenPlant Modeler

    Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.564(SS5) | 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Error/Logs/Message Subarea: Open/Save Original Author: Rahul Kumar…
  • How to duplicate FlexTables

    Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 08.11.XX.XX Area: Output and Reporting Problem Scenario 1 After creating a Project FlexTable you may decide that you want to…
  • ORA-01427 error is appearing on running Automatic Pass

    Product(s): Exor UKPMS Version(s): 04.05.00.00 Environment: N/A Area: Automatic Pass Subarea: N/A Problem Description On running UKPMS Automatic Pass the error message appeared : “ Unknown…
  • Settings and Toolbox Locations Transfer

    I'll be moving from one office to another and the computer I use will not be following with me. I'd like to duplicate my settings and toolbox placement on the 'new' computer. Is there a simple manner in which I can do this?
  • Design History now shows duplicate entries, one for the old file and one for the new.

    Applies To Product(s): MicroStation Version(s): 08.05.02.70 Environment: N\A Area: DGN Subarea: General Original Author: Bentley Technical Support…
  • Duplicate UPF file

    Hi Guys I am wondering if anyone has ever known of MicroStation to produce a duplicate copy of a UPF file and place it under the Bentley Workspace > Systems > Data folder? MicroStation appears to use it and save settings only updates the UPF I have…
  • Importing Duplicate Point Names into Survey

    Product(s): OpenRoads Survey (InRoads, GEOPAK, MX) Version(s): 08.11.09.722+ Area: Survey Original Author: Bentley Technical Support Group Question: When importing Data Files into a Field Book, how does the program…
  • Duplicate defects created

    Product(s): Exor Maintenance Manager Version(s): 4.5.0.0 Environment: N/A Area: Locator Subarea: N/A Problem This is particular to one inspector, each time she adds a defect (in Locator)…