Defining conduit or channel roughness varying with depth or flow
Jesse Dringoli
Applies To Product(s): CivilStorm, SewerGEMS, SewerCAD, StormCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Dan Iannicelli, Bentley Technical Support Group Problem How…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Determining if and when an OpenFlows product was uninstalled
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster Version(s): V8i, CONNECT Edition Area: Problem Is it possible to determine if and when an OpenFlows product…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling arch drain in Flowmaster
Matthew Megill
Hello, does anyone know if it is possible to model an arch drain in Flowmaster? The presumption would be that it is not fully pressurized. Thanks! Edit: Looking at the detail a little closer, it's actually referred to as an arch culvert.
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Can FlowMaster calculate hydraulic grade and energy grade results?
Jesse Dringoli
Product(s): FlowMaster Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Can you generate hydraulic grade and energy grade results in FlowMaster? Solution It is not possible to generate these results…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
The footer of the reports generated in Flowmaster is overlapping or I want to remove the footer.
Jesse Dringoli
Product(s): FlowMaster Version(s): 08.11.01.03 Area: Modeling Problem The footer of the reports generated in Flowmaster is overlapping or I want to remove the footer. Solution Option 1: Download the latest update…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Controlling license access to prevent unintended usage
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, WaterCAD, SewerCAD, FlowMaster, CulvertMaster Version(s): CONNECT Edition, V8i Area: Licensing Original Author: Mark Pachlhofer…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Are OpenFlows products FEMA approved?
Jesse Dringoli
Product(s): PondPack, StormCAD, CulvertMaster, FlowMaster Version(s): V8i, CONNECT Edition Area: General Problem Are Bentley's OpenFlows (water) products FEMA approved? If yes, which versions are FEMA approved? Solution…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Sign in problems or "stopped working" error with CONNECTION Client
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster Version(s): 10.02.00.XX and greater Area: Licensing Introduction Starting with the CONNECT Edition Update 2 release…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
CONNECT Edition Update 2 Releases with CONNECT Licensing
Scott Kampa
We are pleased to announce the availability of the following CONNECT Edition releases: WaterGEMS CONNECT Edition Update 2 (10.02.00.43) WaterCAD CONNECT Edition Update 2 (10.02.00.43) HAMMER CONNECT Edition Update 2 (10.02.00.43) SewerGEMS CONNECT…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Blog
Units not showing in FlowMaster reports
Jesse Dringoli
Product(s): FlowMaster Version(s): 10.00.00.02 Area: Output and Reporting Problem In FlowMaster CONNECT Edition version 10.00.00.02, Reports such as the Detailed Report do not display units. Solution This is a known…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Licenciamiento de los productos de Hidráulica e Hidrología OpenFlows - Subscription Entitlement Service (anteriormente llamado CONNECT Licensing)
Angela Suarez
Producto(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster Version(es): 10.02.00.XX y posterior Area: Licenciamiento Introducción Este artículo explica la activación y administración…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki (Español)
PDF
FlowMaster CONNECT Edition Update 2 (10.02.00.01) Readme
baranski
This document contains installation and licensing details and a list of what's new in this release. Note: you will need to be signed in to Bentley Communities in order to see the Download button.
Readme.pdf
View
Hide
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Files
FlowMaster fails to open or is not able to generate a rating table
Scott Kampa
Product(s): FlowMaster Version(s): 10.00.00.02 Area: Other Problem One of the following symptoms occur: 1) When attempting to open FlowMaster, it starts opening (and displays the intro "splash" screen), but then goes away…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
FlowMaster hangs when opened
Jesse Dringoli
Applies To Product(s): FlowMaster Version(s): 08.11.01.03 Area: Installation Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem Description When opening FlowMaster…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Attempted to read or write protected memory..." error when opening FlowMaster
Jesse Dringoli
Applies To Product(s): FlowMaster Version(s): 08.11.01.03 Area: Modeling Original Author: Akshaya Niraula, Bentley Technical Support Group Problem Description When opening FlowMaster V8i SelectSeries 1, the…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Unexpected Errors during the file conversion" or "foreign key constraint failed"
Jesse Dringoli
Product(s): WaterCAD, WaterGEMS, HAMMER, FlowMaster, SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): 10.XX.XX.XX, 08.11.04.58 Area: Layout and Data Input Problem When attempting to open a model saved in an older version…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Monitoring License Usage - Subscription Entitlement Service (CONNECT Licensing)
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster Version(s): 10.02.00.XX and greater Area: Licensing Problem How can I monitor license usage and view…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"A non-continuable access violation has occurred"
Yashodhan Joshi
Product(s): CulvertMaster, FlowMaster Version(s): 03.03.00.04 (CulvertMaster) 08.11.01.03 (FlowMaster) Area: Other Problem Upon opening CulvertMaster or FlowMaster, the following error appears: "A non-continuable access…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Flow master CONNECT
A
Hi, Once flow master Connect is installed, it shows the following under license is this considered activated ? thanks
Answered
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Licensing OpenFlows | Hydraulics and Hydrology products - SELECTserver
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, HAMMER, PondPack, FlowMaster, CulvertMaster Version(s): CONNECT Edition, V8i, V8 XM Area: Licensing Introduction This article is written for…
6 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Licensing OpenFlows products - Subscription Entitlement Service (CONNECT Licensing)
Larry Abla
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster Version(s): 10.02.00.XX and greater Area: Licensing Introduction This article explains license activation and administration…
5 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
CONNECT Edition releases of PondPack and FlowMaster
Jesse Dringoli
We are pleased to announce the availability of CONNECT Edition of the following Bentley Hydraulics and Hydrology products: PondPack CONNECT Edition (10.00.00.02) FlowMaster CONNECT Edition (10.00.00.02) SELECT and ELS subscribers with existing…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Blog
What's new in FlowMaster CONNECT Edition?
Jesse Dringoli
Product(s): FlowMaster Version(s): 10.00.00.02, 10.02.00.01, 10.03.00.03 Area: Other Overview FlowMaster CONNECT Edition was first released in August, 2018 as version number 10.00.00.02 . The CONNECT Edition was then re…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
File Open Dialog does not appear
Jesse Dringoli
Product(s): WaterCAD, WaterGEMS, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster Version(s): V8i, CONNECT Edition Area: Other Problem When attempting to open a model from File > Open…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
PDF
FlowMaster CONNECT Edition (10.00.00.02) Readme
baranski
This document contains installation and licensing details and a list of what's new in this release. Note: you will need to be signed in to Bentley Communities in order to see the Download button.
Readme.pdf
View
Hide
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Files
<
>