Hevacomp to openbuilding designer. Heating, gas, Hot and cold pipework design.
Paul Jacob
As i understand. Bentley Hevacomp is being retired and replaced with openbuilding designer. I cannot find any training for openbuilding designer to do with plumbing systems. Only ductwork ventilation systems. I would like to know how to design a heating…
over 2 years ago
Hevacomp
Hevacomp Forum
CHP will not connect to an HWS sysytem
Shane Regan
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Environment: N/A Area: Part L Subarea: N/A Overview CHP cannot be directly and solely connected to HWS. Method At…
4 months ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Copying CWS Outlets to HWS
Gerald Robinson
Is it possible to copy outlets between CWS and HWS in Netsys? This would save a lot of time. Thanks
over 5 years ago
Hevacomp
Hevacomp Forum
RE: Same Loading Units Different Flowrates
Shane Regan
For other users who may experience the above - this issue was due to different pipe sizing standards at each outlet. Please find further details here.
over 6 years ago
Hevacomp
Hevacomp Forum
Inconsistent Flow Rate at Outlets
Duncan Brown
Product(s): Hevacomp Version(s): V8i Environment: N/A Area: Netsys Subarea: HWS and CWS Problem Description Outlets in HWS or CWS systems may have differing Loading Units, despite the outlets…
over 5 years ago
Hevacomp
Hevacomp Wiki
RE: How to include Hot water cylinder in Netsys (CWS)
Shane Regan
Hi Jozef, The guidance here should assist with modelling this.
over 6 years ago
Hevacomp
Hevacomp Forum
Same Loading Units Different Flowrates
Jamie Sanderson
Hi I have created a HWS system consisting largely of en-suits of bedrooms. Each en-suite has a two number of basins and 1 shower nozzle. They are calculated using the same method (BS EN 6700), and have the same loading units. They branch coming in…
Answered
over 6 years ago
Hevacomp
Hevacomp Forum
HWS resistance projects
Duncan Brown
Test projects demonstrating: twin pipe outlet connections will include extra outlet resistance when sizing circulation pumps. single pipe outlet connections will not include extra outlet resistance when sizing circulation pumps. These files…
HWS Test Projects - Circulation resistance.zip
over 6 years ago
Hevacomp
Hevacomp Files
CHP will not connect to an HWS sysytem
Shane Regan
Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview CHP cannot be directly and solely connected to HWS. Method At this time,…
over 3 years ago
Hevacomp
Hevacomp Wiki
RE: de-active snap grid
Shane Regan
Hi Arun, you can change this setting by going to Pipes > Defaults, and deselecting the Snap Grid option. Also, if you wish to change the Ortho settings you can do so by going to Defaults>Ortho. You can see this operation if you view this document .
over 7 years ago
Hevacomp
Hevacomp Forum
Including Hot Water System feed in your Cold Water System
Shane Regan
Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: Pipework Design Overview Often as part of a Cold Water System (CWS) there will be a supply to…
5 months ago
Hevacomp
Hevacomp Wiki
Netsys HWS Sample Project
Duncan Brown
Netsys HWS Sample Project - unzip into new folder and open with the Netsys HWS program
SAMPLEHWS.zip
over 7 years ago
Hevacomp
Hevacomp Files
Energy Calculation - HWS demand
Duncan Brown
Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The Daily HWS demand for the Energy Calculation is based on litres/per person…
over 6 years ago
Hevacomp
Hevacomp Wiki