Browse By Tags

  • LRFD 8 - Wind Load Auto Generation

    When using the "Generate Default Load Combination" feature, the load combinations generated are using different factors, like : - 1.4 for WS for STR GP 3, - 0.4 for STR GP 5, - and 0.3 for SER GP 1. LRFD 8 specifies 1.0 factor for all WS regardless…
  • RC Pier (LEAP SubStructure) Live Load Auto Generation Reactions

    How does RC Pier (LEAP SubStructure) account for skew when calculating the bearing reactions for the Auto Generated Live Loads. I can replicate the reactions when there is no skew, but I have issues when skew is applied. Any assistance on the matter would…
  • LEAP Bridge Substructure/RC-Pier LFD Live Loads in the Negative Moment Region

    I am using the LEAP Bridge Substructure module to design a pier for a continuous 4 span structure using HS20 LFD loads. In the AASHTO Standard Specifications, it gives you a few options for the loading. One is that you can use a lane load with one concentrated…
  • Include Truck or Lane Load on Approach when Auto Generating Live Load