Amine Salame
Greetings, I am trying to automate the allocation of wastewater discharges from plots to manholes in SewerGEMS, and for that, I am using LoadBuilder with the options "Point load data" and "Nearest node". The plots wastewater service connections are…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
No items available in Usage Field pulldown menu when adding demands or loading in LoadBuilder
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Problem When using LoadBuilder, there are no available fields available when selecting the Usage Field…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Sewer Gems Loadbuilder cannot assign loads
Md. Rownak Islam
I am importing point load (near to point method) at SEWERGEMS through Load builder from ArcGIS. I have more approx 800 manholes in the network imported through Modelbuilder. However all the load is only assigned to one node only. Not the all nodes.…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
How to manually make changes to assign Property Connection laterals after using LoadBuilder?
Jose Ortiz
So I have imported geolocated water meters (and associated flow data) as Property Connections using the ModelBuilder tool. Then I used LoadBuilder to assign those Property Connections to the nearest link. However, some of the laterals were assigned to…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
using-unit-loads-and-extreme-flow-factors-after-a-loadbuilder-run
JATIN TALWAR, Water Engineer
Hi, I was going through the page https://communities.bentley.com/products/hydraulics___hydrology/w/hydraulics_and_hydrology__wiki/15903/using-unit-loads-and-extreme-flow-factors-after-a-loadbuilder-run wherin the process to assign unit loads using…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Troubleshooting and Understanding LoadBuilder
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Below you will find a list of wiki articles for LoadBuilder in one place. You can either scan this page for your error or use…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
LoadBuilder Error: A very high number of Usage Types were found
Sushma Choure
Product(s): WaterGEMS, WaterCAD, SewerGEMS, Hammer, SewerCAD, CivilStorm Version(s): V8i, Connect Edition Area: Layout and Data Input Problem When trying to use LoadBuilder, the following error message occurs: "Calculations…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Distributing loads based on areas of different Population type
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem How can I distribute loading to manholes based on areas of different population types (such as wards) that have different…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Population Input as plot areas
Suseendar Ramadoss
Hi , I have a shape file of plot areas with number of people residing in each plot area , Is there any option to import these shape file into SewerGEMS and assign these plot area population to Manholes. Nearest node method in load builder module will…
Answered
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Why doesn't my load use type field show up in the "population density type" field?
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, SewerCAD, Hammer, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem Why doesn't my load use type field show up in the "population density…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to view demand or load allocation after a Loadbuilder run?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem Is there any way to graphically view which node each customer demand was allocated to, after running…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error after running LoadBuilder: Export failed
Scott Kampa
Product(s): SewerGEMS, StormCAD, SewerCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition Area: Layout and Data Input Problem When running LoadBuilder, an error message is generated: Export failed. …
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Import loads from shapefile containing polygons with land use type and total population
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX Area: Data Input/Model Creation Problem How can I import loads with Loadbuilder if I have a shapefile…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Unit Loads and Extreme Flow Factors after a LoadBuilder run
Jesse Dringoli
Applies To Product(s): SewerCAD, SewerGEMS, WaterCAD, WaterGEMS Version(s): 08.11.XX.XX through 10.01.XX.XX Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
LoadBuilder importing zero flow loads
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem When trying to bring in loads using LoadBuilder (Projection method…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do each of the LoadBuilder methods work?
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Authors: Jesse Dringoli, Dan Iannicelli, Bentley Technical Support How do each…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
LoadBuilder Error: "# Id(s) do not match any id of the model..."
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): 08.11.XX.XX and 10.00.00.XX Area: Modeling Problem When running LoadBuilder the following errors appear. "# ID(s) do not match any IDs in the model." "Calculations…
over 6 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Introducing individual Property Connections to your model
Craig Calvin
Have you ever wanted to add sanitary loads to a sewer model based on individual property data? Perhaps you have loading data provided for customers, or properties and would like to include it for a more detailed hydraulic model. Starting with the CONNECT…
over 7 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Blog
Using LoadBuilder to assign Property Connections to the nearest element while creating taps and/or laterals
Larry Abla
Product(s): SewerGEMS, SewerCAD Version(s): 10.00.00.40 and later Area: Modeling Introduction LoadBuilder can be used to assign isolated Property Connection elements to the nearest element by creating a tap and lateral…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Calculations failed due to one of the following reasons..." when trying to use Loadbuilder in ArcMap
Jesse Dringoli
Applies To Product(s): Bentley WaterGEMS, Bentley SewerGEMS, Bentley HAMMER Version(s): 08.11.XX.XX Environment: N/A Area: Original Author: Mark Pachlhofer, Bentley Technical Support…
over 7 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do you consider only a selection set of elements with LoadBuilder?
MPachlhofer
Applies To Product(s): Bentley WaterGEMS, Bentley WaterCAD, Bentley SewerGEMS, Bentley CivilStorm, Bentley SewerCAD Version(s): 08.11.xx.xx Area: Modeling Original Author: Jesse Dringoli, Bentley Technical…
over 6 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
LoadBuilder applying demands or loads to inactive elements
Larry Abla
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem When applying demands or loading data to a model using LoadBuilder, it appears like demands are being…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the Flow Monitoring Distribution method in LoadBuilder
Scott Kampa
Applies To Product(s): SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Layout and Data Input Original Author: Jesse Dringoli, Bentley Technical Support Group Overview This TechNote…