Peter Sande
Qeustion: When having two lines connecting w a flange connection, what rules apply to which line contains the Gasket and bolts ?
over 3 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OPIM Dimension Text Upside Down
robert cali
There is an inconsistent error with OPIM 10070032en where the program rotates dimension text upside down when schema is edited. Sometimes modifying schema there is no issues and sometimes it will cause this error. NOTE: The upside down dimension text…
Answered
over 3 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OPM Ce Custom Components ISO
Peter Sande
Does anyone have hints on How To Get Topworks / Operators to be shown on Iso's. We want Operator description and Orientation. Can this be achieved by using 'attributes' of components, and then trigger IsoMetric Manager to populate values on ISO's…
over 3 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to Delete Levels and Create Custom Level List in OPIM Seed File
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 Environment: Windows 8/10 Area: Settings/Attributes Subarea: - Original Author: Michelle…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Adjust Imperial Accuracy in OpenPlant Isometrics Manager
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 Environment: Windows 8/10 Area: Settings/Attributes Subarea: - Original Author: Michelle…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Add NEW Schema Field to Component for Custom Tagging in OpenPlant Isometrics Manager
Kestutis Mitkus
Applies To Product(s): OpenPlant Modeler / OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Class Editor / Isometric Configuration Subarea…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Add Inch Sign with Nominal Diameter in Pipeline Tag
Jaya Tiwari
How to Add Inch Sign with Nominal Diameter in Pipeline Tag
How to Add Inch Sign in pIpeline Tag (OPM).mp4
View
Hide
over 5 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Files
Property is Read Only Error in OpenPlant Modeler
Jaya Tiwari
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.87(SS6) & Higher Environment: Windows 7/8.1/10 (64 bit) Area: Error/Logs/Message Subarea: Iso Sheet Generation…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Not Include Gasket as a Joint for Flanged Components in OpenPlant Modeler
Rahul Kumar
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Graphics Original Author: Rahul Kumar, Bentley…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
RE: ECExpression String Escape sequence
Rahul Kumar
Hello Peter, You can check one wiki related to new line output in BOM. This will serve the purpose. HTH -Regards | Rahul Kumar
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: OPIM SS6 - B0 bolt label
Rahul Kumar
Hello Tuan, This is a known issue. If there is no Part ID present in OpenPlant Isometrics Manager, then it display a B0 label. This has been fixed in latest version of OpenPlant Isometrics Manager. HTH -Regards | Rahul Kumar
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: Report OPM Model Name on the Isometric OPIM
Rahul Kumar
Thanks Ray, We will evaluate this & let you know. -Regards | Rahul Kumar
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: How to show Tracing in OPM and OPIM
Rahul Kumar
Thanks Ray, We have logged an Enhancement # 382891 based on SR # 7000562506 you have logged. This will further gets evaluated by product management team. HTH -Regards | Rahul Kumar
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to set Different PLANT North in OpenPlant Isometrics Manager
Rahul Kumar
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings\Attributes Subarea: Style.cfg Original Author: Rahul Kumar, Bentley…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Use Various Iso-Sheet Splitting options in OpenPlant Isometrics Manager
Rahul Kumar
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Isometric Configuration - Automatic iso splitting …
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Suppress Co-ordinates & Display Elevations in OpenPlant Isometrics Manager
Rahul Kumar
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 (SS6) & 08.11.11.103 (SS6) above Environment: Windows 7/8.1/10 (64bit) Area: Settings/Attributes Subarea: Elevation-Coordinates …
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Hide supports in OpenPlant Isometrics Manager
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 Environment: Windows 7 (64 bit) & others Area: Settings/Attributes Subarea: Original Author…
over 5 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Display Support Orientation in OpenPlant Isometrics Manager
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author…
over 5 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
RE: Where i find the different gauges in OpenPlant Modeler
Rahul Kumar
Thanks to confirm Markus, I should have written that. As Gaurav Mentioned, sometimes for any sub classes if you need different graphical symbol (with different ports etc), then component scripting part required if it is not available. You can request…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
DOCX
Error Distance Between Gasket [Gasket][GUID No] & Adjoin Components could be more than 1.5
Rahul Kumar
Error Distance Between Gasket [Gasket][GUID No] & Adjoin Components could be more than 1.5
Error Distance Between Gasket [Gasket][GUID No] & Adjoin Components could be more than 1.5.docx
View
Hide
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant Files
Error Distance Between Gasket [Gasket][GUID No] & Adjoin Components could be more than 1.5
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Isometrics Generation Original…
over 5 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Concatenate Length Property in Description Field for BOM
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul…
over 5 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Fix Multi Way Valve Symbol Issue in OpenPlant Isometrics Manager
Rahul Kumar
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 8.11.09.XXX(SS5) | 08.11.11.XX(SS6) Environment: Windows 7/8.1/10/(64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Display Sum of Bolt Length and Bolt Excess Length in BOM
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.574 Environment: Windows 7( 64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
Displays Error[5]-DWG creation failed While Generating Isometric Output as DWG Format
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Isometric Configuration Original…