Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
OPM
OpenPlant Isometrics Manager
08.11.09.404
08.11.09.440
08.11.09.564
08.11.09.574
08.11.09.XXX
08.11.10.xxx
08.11.11.87
08.11.11.xx
08.11.11.xxx
apm
APM-OPIM
AutoPLANT Modeler
Bolt
BOM
DB Query
FFW
FW
isometrics
Labels
OpenPlant Modeler
OPIM
PARTID
SS6
support
User Labels
RE: OPIM with OpenPlant Modeler using textnode.txt to add extra data from external sources
Rahul Kumar
Thanks Ray, Glad to know that you find it useful. However on adding the information in IsoProj.cfg file, we will include that in wiki. However this variable exist by default. -Regards | Rahul Kumar
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to Round Off Values After Decimal For Support Co-ordinates
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
To Display Multiple Rows for Notes as Labels
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author…
over 5 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Get Updated Revision in Isometrics Drawing Using DBQuery
Rahul Kumar
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.xxx (SS5) | 08.11.11.xxx (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
Grouping of Supports Based on Common Tag Name
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Configuring the BOM and Reports…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Get Tag Number on Valves
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author: Dinesh Solanki, Bentley Product…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
RE: OPM & OPIM - Can't load iModel
Rahul Kumar
Hello Gary, OpenPlant Modeler Version you mentioned as 08.11.09.564 which is a 5XX series version and OpenPlant Isometrics Manager you are using of 4XX series i.e. 08.11.09.458. This does not seems correct. Please change either of them and try.
over 8 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to Assign FieldFit Weld Allowances or Other Weld Types for BOM & Cut List in OpenPlant Isometrics Manager
Kestutis Mitkus
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.277 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul…
over 4 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
How to Add Weld Tag as FW/FFW on Isometrics weld in OpenPlant Isometrics Manager
Abhijit Bute
Applies To Product(s): OpenPlant Isometrics Manager CONNECT Edition Version(s): 10.XX.XX.XX Environment: Windows 10 (64 bit) Area: Settings/Attributes Subarea: Original…
over 2 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
<