Browse By Tags

  • OPM SS6 - Custom Two Stage Valve

    Hi, How to add Custom Two_Stage_Valve in OPM Looking forward to your help Regards
  • Question about EC Annotation

    Hi Everyone, I have a question about placing EC Annotation. The background is I added two property to pipe, called COP_M and BOP_M. which represents the height of Center of Pipe and the height of Bottom of Pipe respectively. Then, I added two EC Annotations…
  • 请问Openplant的中国国标库有公用的吗?

    RT...
  • Annotation on OPM CE saved view

    In OPPID, we can annotate pipelines by simply click the annotation tab, and then move the cursor to the pipe, the pipeline number will pop up, so we can place it. If we want to annotate another pipeline, all we need to do is moving the cursor to the target…
  • How to display different quantity and unit in one external report in OPM CE

    HI Everyone, My question is how to calculate different component with different unit in OPM, the background is we want all the piping component be calculated in one report(include pipe, elbow, reducer, tee, specified gasket and bolts). The pipe should…
  • Few questions about custom report of OPM CE

    HI Everyone, I met some problem when customizing reports for equipment in OPPA CE, here're the questions. First, How to group the equipment by higher class rather then the only base class, for example, Par. Horizontal Pump and Par. V-Inline Pump are…
  • New component in flange joins.

    Hi guys. How do I add nuts to a flange joint? So that there are bolts, gaskets, nuts in catalogs.
  • To Export and Import Nozzle Definitions in case of Equipment move issue

    Applies To Product(s): OpenPlant Modeler Version(s): V8i (08.11.11.304) Environment: Windows 8.1/10 (64 bit) Area: Error Subarea: Original Author: Soham Mhaskar, Bentley Product Advantage Group …
  • To populate Shop in existing Component’s Shop Field

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT EDITION (10.09.00.74) Environment: Windows 10 (64 bit) Area: Configuration Subarea: Original Author: Soham Mhaskar, Bentley Product Advantage…
  • OPM中使用DV切图显示样式问题

    环境:OPM up7 我在OPM中使用DV切图,选择样式是【消隐线】,显示如下图 切完图后,变成了下图 多了很多线条,请问有什么办法能够简化切图结果?
  • How to ChangeSpec/ChangeSize of valves without the loss of the operator?

    When we change the Specification or the Dimension of Valves via Pipeline Manager the Operators are disappearing. We have to place every valve again or the operator itself. Is there a way to change that? Thanks for any help.
  • OPM & OPIM SS6 - isometric continuation with pipeline in reference file

    Hi all, How to do isometric extraction with a continuation line where the continuation (pipeline) is in a reference file. Looking forward to your help. Best regards. Salim
  • How To Pick Nozzle Length From Spec Database in OpenPlant Modeler Connect

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.09.00.74 (Update 9) Environment: Windows 8.1/10 (64-bit) Area: Modeling Subarea: Specifications Original Author: Aishwarya Kulkarni…
  • How to Modify Hand Wheel Stem Thickness in OpenPlant Modeler CONNECT

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 8.1/10 (64-bit) Area: Spec Subarea: Component Original Author: Aishwarya Kulkarni, Bentley…
  • OpenPlant V8i SS5 or SS6

    Hi. I know OpenPlant V8i is a discontinued product suite, but I need to download evaluation version of Modeler, Isometrics Manager and Project Administrator (better if SS6 version) for testing purpose (and to migrate old workspaces to CONNECT Edition…
  • Custom Supports Changing Location

    OpenPlant Modeler V8i (SS6) 08.11.11.304 Hello, We have been placing custom supports based on the link below: https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21404/to-add-custom-cell-for-supports-in-openplant…
  • OPM等级库编辑器报错

    如图所示,我用opm自带的等级库编辑器建等级库时,不能通过minsize和maxsize筛选,一直报错,错误信息如下。 System.ArgumentOutOfRangeException: Index was out of range. Must be non-negative and less than the size of the collection. Parameter name: index at System.ThrowHelper.ThrowArgumentOutOfRangeException…
  • CE update5版 OPPA报表制作问题

    使用CE update5版 OPPA制作报表过程中,对于REDUCER(大小头),PIPE_TEE_REDUCING_BRANCH(异径三通)这类管件,需要显示RUN_SIZE和BRANCH_SIZE两个字段,但field list中没有相应数据,请问该如何处理?
  • V8i版本isometric出图问题

    对于非管中心线处开孔的支管,V8i版本Isometric软件压出来的iso图未能将其位置标示出来,而是标注了两个“0”,“0”,如下图: 而CE update5 版的Isometric 则能正常标示出来(管道中心线向下54mm): 我仔细对比了二者的出图配置是一样的,请问V8i版能否也像CE版本那样标示出支管开孔位置? 另外能否告知下V8i版本标示出来的两个“0”,“0”代表什么意思,感谢!
  • OpenPlant - Additional Licenses

    Good Afternoon, while installing OpenPlant Modeler v10.14.1.4, I noticed that two Technology Preview Features are available, OpenPlant Support Engineering and Raceway And Cable Management. Do they require addiional license? Are there other features…
  • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 8.1/10 (64-bit) Area: Customization Subarea: Property Original Author: Aishwarya…
  • How To Map Custom Double Type Property in OpenPlant Modeler Connect

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 8.1/10 (64-bit) Area: Customization Subarea: Schema Original Author: Aishwarya Kulkarni…
  • How to Fix Generic Valve Insertion Issue in OpenPlant Modeler Connect

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 10 (64-bit) Area: OpenPlant Modeler Subarea: Placement Original Author: Aishwarya Kulkarni…
  • How to Add the Plant Area Property Name in Tag Name For Equipment

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 10 (64-bit) Area: Customization Subarea: Tagging / Attribute Original Author: Aishwarya…
  • How to Create New Spec Using OpenPlant Specification Generator CONNECT Edition.

    Applies To Product(s): OpenPlant Modeler Version(s): CONNECT Edition 10.08.00.51 (Update 8) Environment: Windows 10 (64-bit) Area: OpenPlant Modeler Specification Generator Subarea: Spec Creation Original…