Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
PondPack
SewerGEMS
AutoCad
CivilStorm
Composite Outlet Structure
CONNECT Licensing
CulvertMaster
FlowMaster
HAMMER
installation
integration
licensing
MicroStation
Migrated
ModelBuilder
Modeling
Reviewed2016
reviewed2017
Reviewed2018
Reviewed2019
Reviewed2020
SewerCAD
Shapefile
StormCAD
Subscription Entitlement Service
WaterCAD
WaterGEMS
Hints for troubleshooting machine-specific issues / errors
Jesse Dringoli
Product(s): WaterCAD, StormCAD, WaterGEMS, SewerCAD, Hammer, CivilStorm, SewerGEMS, PondPack, Flowmaster, Culvertmaster Version(s): V8i, Connect Edition Area: Installation Problem What things should I check in case I understand…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Access to the path... is denied" in log file
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER,, WaterCAD Versions: All Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem When I look…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Flex table reports appear blank
Sushma Choure
Product(s): Bentley WaterGEMS, WaterCAD, Hammer, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Output and Reporting Problem Flex table reports appears blank though there are…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Do I need to reinstall if I upgrade my feature level? (such as the number of pipes)
Jesse Dringoli
Product(s): Bentley WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, Hammer, WaterCAD Version(s): V8i, CONNECT Edition Area: Licensing Problem Do I need to uninstall and reinstall the OpenFlows product and…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Important License Update for OpenFlows Users
Jesse Dringoli
If you are using a V8i version of an OpenFlows product, or an earlier CONNECT Edition with version number below 10.02, please watch this important update! See more in our Wiki: Important License Update for OpenFlows Users Best Regards, Bentley…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Enhancing OpenFlows multi-user workflows with ProjectWise Share
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster Version(s): CONNECT Edition Area: Collaboration Background ProjectWise Share (PW Share), part of the…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Important License Update for OpenFlows Users
Larry Abla
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster Version(s): 10.01.XX.XX and earlier Area: Licensing What is this about? Bentley has replaced SELECTserver…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Legend created from color coding is coming in too large
Jesse Dringoli
Product(s): WaterCAD, WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem When inserting a color coding legend, it is too large or the icons…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Text, Line, and Border feature
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Background What are typical use cases for the Text, Line, and Border feature in…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Inserting or laying out pipe bends
Jesse Dringoli
Product(s): Bentley WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem How can I lay out a bend in a pipe when working…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Get to know OpenFlows CONNECT Edition
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster Version(s): CONNECT Edition Are you new to the CONNECT Edition of Bentley's OpenFlows products or still using an…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Distributing catchment runoff evenly over a channel or multiple inlets
Jesse Dringoli
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD Version(s): V8i, CONNECT Edition Area: Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem How…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Zoom Dependent Visibility to cause elements to disappear at certain zoom levels
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Environment: Standalone Area: Modeling Original Author…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Working From Home With Your OpenFlows Software
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster, FLOOD, WaterOps, SewerOPS Version(s): CONNECT Edition If you have a need to work remotely or from home, Bentley…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Notifications about minimum or maximum elevations on the rating table not matching the headwater range
Scott Kampa
Applies To Product(s): PondPack, SewerGEMS, CivilStorm Version(s): 08.11.01.56 (PondPack) 10.XX.XX.XX (other) Area: Modeling Original Author: Akshaya Niraula, Bentley Technical Support Group …
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the "Elevation (On)" and "Elevation (Off)" fields in a Composite Outlet Structure
Jesse Dringoli
Product(s): PondPack, SewerGEMS, CivilStorm Version(s): V8i, CONNECT Edition Area: Modeling Problem What is the purpose of the "Elevation (on)" and "Elevation (off)" fields in the properties of an outlet component in the…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modelling of an Offline Detention System
Arunima Gupta
Dear Team, I am modelling an offline detention system near an outfall. Scenario 1- Entire flow enters the pond, and then from here flow has an outfall channel into an outfall. it is an entire gravity system, where in water enters the pond and head…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Reporting model element latitude and longitude
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm, StormCAD, PondPack Version(s): V8i, CONNECT Edition Area: Output and Reporting Problem I need to present model results to another agency or reviewer…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Catchment user notification about the difference between the calculated peak flow vs. interpolated peak flow being greater than 1.5%
Jesse Dringoli
Applies To Product(s): CivilStorm, SewerGEMS, PondPack Version(s): CONNECT Edition, V8i Area: Output and Reporting Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem After I…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
WaterObjects.NET - How can I create a child scenario?
Jesse Dringoli
Product(s): WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack Version(s): V8 XM, V8i, CONNECT Edition Area: Modeling Problem How can I create a child scenario in a WaterObjects.NET project?…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Hydraulic Modeling and Detention Pond Troubles
Colby Cofield
Hello, I have been trying to design a detention pond within SewerGEMS for a few months now to only partial success. I am designing the retention pond along side a simple catchment system but cant figure out what settings i have wrong that are…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Determining if and when an OpenFlows product was uninstalled
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster Version(s): V8i, CONNECT Edition Area: Problem Is it possible to determine if and when an OpenFlows product…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Designing a Detention Pond based on a Watershed
Colby Cofield
Hello! I am very new to SewerGEMS and I am doing a project for my senior capstone in college. Our goal is to design a detention pond to capture runoff so that the runoff does not directly go into a duck pond, down a stream on the side of the hill. …
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
OpenFlows software numerical solver theory
Sushma Choure
Applies To Product(s): CivilStorm, StormCAD, WaterCAD, WaterGEMS, SewerGEMS, SewerCAD, PondPack, Flowmaster, Culvertmaster Version(s): V8i, CONNECT Edition Area: Help and Documentation Original Author: …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Composite Outlet Structure
Mohamad Azzam
For the composite outlet structure for a pond is consist of several items (Weir, Riser, culvert and orifice), does anybody have photos presenting the options of the combination of items? how physically combined together? sharing illustrating picture…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
<
>