Browse By Tags

  • Change code check color scale in RAM Frame

    Is there an option to change the color scale in code check (RAM frame)?. Majority of the utilization ratio is anywhere between 10-50% in my model. I can see only blue now, would like to differentiate the members with 40-50% in one color and 30-40% in…
  • RAM Frame Deflected Shape Error (ISM import)

    We have created a RAM model from an ISM export from Revit. After cleaning up a multitude of errors associated with the import, we got the model into RAM Frame to analyze for wind loading. When running the model under dead, live, and a user input wind…
  • RAM Manager thinks I have a module open

    Hello all, RAM Manager thinks I have a module open and prevents me from closing Manager. Also, it does not allow me to select a module to continue. This is what it looks like: Can someone help? What is going on? I have version 17.02.01.23 SES. I…
  • RAM Frame glitch

    Good morning, I have a little issue with RAM Frame/SS. When I close RAM Frame it starts glitching. A message pops up telling me that a module is open when is not the case. I cannot save my work, I cannot close the program, and even when I close it…
  • Illegal Framing Configuration Issue

    Greetings, I am having the usual Illegal Framing Configuration Issue error on a model I am working on. This time following the other responses to this issue are not helping due to the complexity of the slab edges on the levels. I have tried redrawing…
  • RAM SS Diaphragm Force Report

    When cutting a semi-rigid diaphragm to find the diaphragm forces, which direction should be cut for X- and Y- load direction? i.e. Looking for diaphragm moment Y-direction to find chord forces, would a cut parallel to Y-axis near "mid-span" of diaphragm…
  • Ram SS ERROR Section property not assigned for column number ## on story first

    Not sure how to reconcile this error, the column has already been assigned and deleting it and bringing it back in doesn't fix the issue either. any help appreciated
  • Controlling Fundamental Building Period

    I am running the seismic analysis for a 3 story structure and have questions about how to determine the appropriate building period to use for the seismic analysis. Gravity system is typical steel frame, with composite slab/framing at 2nd and 3rd Floors…
  • Ram SS Large Nodal Displacement

    I have a 2 story building where the lower portion of the floor plan must cantilever out due to existing conditions. I modeled the cantilever using a combination of gravity extensions and stubs as shown in the floor plans. When I run RAM SS and go through…
  • CMU and CFMF shear walls in RAM SS

    I am trying to analyze a building with CMU and CFMF shear walls. The diaphragm is a metal deck with 3" of concrete supported by CFMF floor trusses. I understand that RAM SS does not design CMU and CFMF shear walls but is there a way I could at least get…
  • Lateral load transfer outside diaphragm area - RAM Frame

    Is there a way to transfer lateral loads to a braced frame that is outside of the diaphragm boundary? Would lateral beam members acting as drag struts transfer these loads? (we are modeling a semirigid diaphragm)
  • RAM SS Frame | Seismic Drift Period of Structure

    We are following ASCE 7, AISC 360, and the Direct Analysis Method in the RAM Structural System to analyze a building with direct analysis method. In step 6, it mentioned "As stated previously, it is generally felt that the building period used in…
  • RAM SS Merging Nodal Loads

    Hello, I have a three story building with a rigid diaphragm on levels 2 and 3 (level 1 is ground). My roof is a metal deck and I want to analyze it as flexible. I created my Nodal load cases labeled Roof-X and Roof-Y, both Seismic Load type. I need…
  • Unbraced Length of Lateral Columns in RAM SS

    How shall we assign the unbraced length of lateral columns in a building with a mix of lateral and gravity columns supporting a flat slab? The building does have shear walls as well as a part of MWFRS. I know for gravity columns, it will be safe to…