Browse By Tags

  • WARNING- Deflection check of member # 11 will not be performed as DFF value not provided.

    I am getting this warning: WARNING- Deflection check of member # 11 will not be performed as DFF value not provided. I am sharing the input command. Please provide your view. STAAD SPACE START JOB INFORMATION ENGINEER DATE 15-May-23 END JOB INFORMATION…
  • How does RAM compute the transformed MOI for AISC's effective MOI?

    Hello, I am wondering how RAM Steel computes the I_{tr} for composite beams. For example, I have a composite beam with the following properties as computed by RAM: But by hand, I am computing I_{tr} = 941.86, slightly less than RAM. I am guessing…
  • RAM Connection

    Everything Needed for Steel Connection Design RAM Connection can check or design connections in seconds. Whether you design connections or need to check connections designed by the shop, RAM Connection is the software for you. In just one low-cost package…
  • AISC 360 F9 Major Axis Bending WT

    Applies To Product: RAM Steel First Affected Version: Found in Version: 15.03.00.00 Fixed and Released in Version: 15.04.00.00 Area: Design Issue #: 571350 Problem Description…