2D Modeling in SewerGEMS and CivilStorm
Scott Kampa
Product(s): SewerGEMS, CivilStorm Version(s): CONNECT Edition Update 4 and later (10.04.00.158+) Area: Modeling Overview Starting with OpenFlows SewerGEMS and OpenFlows CivilStorm CONNECT Edition Update 4 (10.04.00.158+), you…
1 month ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the Pipe Matching and Matchline Offset Design Constraints
Jesse Dringoli
Product(s): SewerCAD, StormCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem How do the "Pipe Matching" and "Matchline Offset" design constraints work, when performing a constraint-based design…
1 month ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Can we use sewerGEMs for storm water modelling?
TOUFIK MANER
hello My name is Toufik Maner. I am going to work on" Storm Water Modelling" project using SewerGEMS and I am new to this software. Could somebody please tell me whether I can use SewerGEMS Software to model storm water system having natural streams…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Using the Time Browser
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack Version(s): CONNECT Edition Area: Output and Results Problem What is the purpose of the Time Browser tool and how do I use it? Solution The…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Culvert headwater not matching HY-8
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS, OpenRoads Designer Version(s): 10.03.04.53 and earlier Area: Calculations Problem Headwater results with culverts and headwalls are not matching HY-8. Solution The culvert…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling RTK Inflows with the Implicit or SWMM solver
Jesse Dringoli
Applies To Product(s): SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Layout and Data Input Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem How do you…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error opening model after editing Engineering Profile: Input string was not in a correct format
Scott Kampa
Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition Area: Modeling Problem The following error message is generated when opening an existing model: Input string was not in a correct format. …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Runoff methods supported by each solver
Jesse Dringoli
Product(s): SewerGEMS, StormCAD, CivilStorm, SewerCAD Version(s): CONNECT Edition, V8i Area: Layout and Data Input Overview OpenFlows Storm and Sewer products have been supporting several runoff calculation methods. This…
3 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Understanding the impact of multiple barrels for a conduit
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem What does the "Number of Barrels" field mean for a conduit? What impact does this have? Solution The "Number…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Log4net issues appear in security scans for OpenFlows products
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 10.03.05.05 and earlier (water), 10.03.04.53 and earlier (storm/sewer) Area: Security Problem A system security scan indicates…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What's New in SewerGEMS, CivilStorm, SewerCAD, and StormCAD CONNECT Edition Update 4 (version 10.04.00.158)
Scott Kampa
Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): 10.04.00.158 Area: Installation Overview CONNECT Edition Update 4 (version 10.04.00.158) of SewerGEMS, CivilStorm, SewerCAD, and StormCAD introduces improvements…
6 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Manhole or catchbasin inflow is not equal to the outflow with the Implicit or Explicit solver
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Why doesn't the "Flow (Total In)" match the "Flow (Total Out)" result in the properties of a manhole or catchbasin when…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling a separate spillway (weir) and Riser in a pond
Jesse Dringoli
Product(s): PondPack Version(s): CONNECT Edition, V8i Area: Modeling Problem What is the best way to model a pond that has a spillway (weir) that operates separately from (in parallel with) another outlet structure such as…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is it possible to delete an element from one scenario, but retain it in another?
Jesse Dringoli
Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Entwässerungs- und Versorgungsleitungen
Matthias Heise
Produkt: OpenRoads Designer Connect Edition Version: 10.07.00+ Bereich: Entwässerungs- / Versorgungsleitungen Autor: User Success In dem Workflow Entwässerungs- und Versorgungsleitungen nutzen wir Lösungen von Bentley…
3 months ago
OpenRoads | OpenSite
OpenRoads | OpenSite - Wiki (Deutsch)
View associations of element symbology in Microstation Integration mode.
Sushma Choure
Product(s): Bentley SewerGEMS, CivilStorm, SewerCAD, StormCAD, WaterCAD, WaterGEMS, Hammer Version(s): V8i, Connect Edition Area: Output and Reporting Problem Can we associate different symbology definitions to different…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Can we model sewage treatment plant units in SewerGEMS / CivilStorm?
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm, SewerCAD Version(s): Connect Edition, V8i Area: Modeling Problem Can SewerGEMS or CivilStorm model hydraulic components of a sewage / waste water treatment plant? Solution The OpenFlows…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"The outlet structure's entered minimum headwater elevation X ft is greater than or equal to the entered maximum headwater elevation X ft..."
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS, OpenRoads Designer Version(s): CONNECT Edition Area: Layout and Data Input Problem When attempting to compute a model, the following User Notification appears and the calculation…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User Notification "The controls in the conduit are ignored by this solver"
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS, OpenRoads Designer, OpenSite Designer Version(s): CONNECT Edition, V8i Area: Calculations Problem When computing a model with the GVF-Convex (StormCAD) solver, the following user…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error Installing: "Error 1935. An error occurred during the installation of assembly"
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Installation Problem When installing a Bentley Hydraulics and Hydrology…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Slow performance when using SWMM solver with a large number of inlets
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm Version(s): 10.03.04.53 Area: Calculations Problem My model takes an excessively long time to compute when using the Explicit (SWMM) solver with a large number of catalog inlets. Solution…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error exporting storm-sewer model to Micro Drainage – Labels do not contain pipe numbering in the correct format
Sushma Choure
Product(s): Bentley SewerGEMS, CivilStorm, StormCAD Version(s): V8i, Connect Edition Area: Output and Results Problem Error on exporting storm-sewer model to Micro Drainage – Labels do not contain pipe numbering in the correct…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is there a way to hide unwanted columns in conduit catalog?
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem How do I hide unwanted columns in conduit catalog? While adding a new catalog class in the conduit…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Irregular Weir Flow Calculations in a Composite Outlet Structure
Jesse Dringoli
Product(s): PondPack, SewerGEMS, CivilStorm Version(s): CONNECT Edition Area: Calculations Problem How is weir flow calculated when using the Irregular weir option in a composite outlet structure, in PondPack, SewerGEMS or…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Deleting multiple patterns (bulk delete)
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD, Version(s): CONNECT Edition Area: Modeling Problem I have a large number of patterns in my model that I need to delete. The pattern manager does not allow me to multi-select. How can I batch…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>