Jesse Dringoli
Product(s): SewerCAD, StormCAD, CivilStorm, SewerGEMS Version(s): CONNECT Edition, V8i Area: Calculations Problem Is it possible to have the constraint based design feature design a conduit's inverts but not the…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User notification: "There should be only one non-diversion type conduit out of a gravity junction"
Yashodhan Joshi
Product(s): SewerCAD, StormCAD, CivilStorm, SewerGEMS Version(s): CONNECT Edition, V8i Area: Modeling Problem When computing a model, the following user notification is generated: "There should be only one non-diversion type…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Labels only showing up for some elements when using Label Features in ArcGIS mode
Scott Kampa
Product(s): WaterGEMS, SewerGEMS, Hammer Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem When labeling features in the ArcMap platform, why does the label not show up for some elements? Solution 1…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Zero flow in model despite successful run and presence of storm or loading
Jesse Dringoli
Applies To Product(s): CivilStorm, SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Nancy Mahmoud, Bentley Technical Support Group Problem Zero flow is…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Why does the gutter need to be defined in both the catch basin and gutter element?
Jesse Dringoli
Product(s): StormCAD, CivilStorm,SewerGEMS, FlowMaster Version(s): 10.00.xx.xx, 08.11.xx.xx Area: Modeling Problem The gutter and catch basin elements both seem to have the same fields for defining whether the gutter…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling treatment for pollutants at nodes or ponds in SewerGEMS and CivilStorm
Jesse Dringoli
Applies To Product(s): CivilStorm, SewerGEMS Version: CONNECT Edition, V8i Area: Layout and Data Input Problem What is the workflow to model treatment for pollutants in nodes and ponds using the Explicit…
10 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I find the Total Dynamic Head (TDH)?
Jesse Dringoli
Product(s): WaterGEMS, SewerCAD, WaterCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Calculations Problem How can I find the Total Dynamic Head (TDH) of one or more pumps? Solution The Total Dynamic…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Civil3D integration (Pipe network import/export)
Larry Abla
Product(s): StormCAD, Civilstorm, SewerGEMS, SewerCAD, WaterCAD, WaterGEMS, HAMMER Version(s): V8i, CONNECT Edition Area: Data Import/Export Problem How do the OpenFlows products integrate with AutoCAD Civil 3D? How can…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using US Survey feet
Jesse Dringoli
Applies To Product(s): StormCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Other Original Author: Jesse Dringoli, Bentley Technical Support Group Problem How…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Filter FlexTable to only show active elements
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Output and Reporting Problem How do you filter the FlexTables so only active…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Exporting hydraulic models to Google Earth KMZ
Sushma Choure
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Other Problem How can a hydraulic model be exported to Google Earth? (.kmz file) Solution - MicroStation Open the WaterGEMS…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Filtering a Flextable on Zone = "None"
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling Problem How can you filter a flextable on Zone = "None"? Problem ID#: 46478…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is there any way to only adjust the pipe size without changing the invert?
Yashodhan Joshi
Product(s): SewerCAD, StormCAD, SewerGEMS Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling Problem When I used the constraint based design function it changed the pipe (manhole) invert and pipe size, however…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do you associate a pump to a pump station?
Sushma Choure
Product(s): WaterCAD, WaterGEMS, SewerGEMS, SewerCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem How do you associate a pump to a pump station? What is the difference between a pump…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Library is read only. Library cannot be edited.
Sushma Choure
Product(s): CulvertMaster, SewerGEMS Version(s): 03.03.01.04, 08.11.XX.XX Area: Other Problem When attempting to edit an engineering library for editing a section size or exporting user defined data, the following error occurs…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Global storm events dropdown not showing all events
Sushma Choure
Product(s): StormCAD, SewerGEMS, StormCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem When I open the Global Storm Event manager from the Components pulldown, one of the global storm events created…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Import loads from shapefile containing polygons with land use type and total population
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX Area: Data Input/Model Creation Problem How can I import loads with Loadbuilder if I have a shapefile…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I change the SCS Unit Hydrograph shape factor?
Larry Abla
Product(s): Bentley PondPack Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem How can I change the SCS unit hydrograph shape factor in Pondpack V8i? Problem ID#: 42169 Solution First, choose "Triangular…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Can constraint based design size open channels?
Yashodhan Joshi
Product(s): StormCAD, SewerGEMS, CivilStorm Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling Problem Is StormCAD (or the GVF-Rational Solver in CivilStorm/SewerGEMS) able to size open channels with constraint based design…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How is Initial Abstraction considered with the SCS Unit Hydrograph method?
Sushma Choure
Product(s): Bentley SewerGEMS, CivilStorm, PondPack Version(s): 08.11.XX.XX, 10.00.XX.XX Area: Calculations Problem Is the Initial Abstraction taken into account regarding the Storm Rainfall Depth versus the Runoff Depth…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I apply the 'Swamp Factor' when using the SCS Unit Hydrograph or the Tabular TR-55 methods?
Larry Abla
Product(s): PondPack, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Data Input Problem How to apply the swamp factor when using the SCS Unit Hydrograph or the Tabular TR-55 methods? Solution The…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Where is the Gutter Depth measured from?
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): 08.11.XX.XX and 10.XX.XX.XX/td> Area: Calculations Problem Where is the 'Gutter Depth' result field measured from, when using the GVF-Rational solver? Is it measured…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Troubleshooting unstable SewerGEMS and CivilStorm model results using the Explicit SWMM Solver
Jesse Dringoli
Applies To Product(s): CivilStorm, SewerGEMS Version(s): CONNECT Edition, V8i Area: Layout and Data Input Original Author: Jesse Dringoli, Bentley Technical Support Group Problem When using the Explicit (SWMM…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Unit Loads and Extreme Flow Factors after a LoadBuilder run
Jesse Dringoli
Applies To Product(s): SewerCAD, SewerGEMS, WaterCAD, WaterGEMS Version(s): 08.11.XX.XX through 10.01.XX.XX Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the purpose of the left and right overbank option for an Irregular Channel?
Jesse Dringoli
Product(s): CivilStorm, SewerGEMS, StormCAD Version(s): CONNECT Edition, V8i, V8 XM Area: Layout and Data Input Problem What is the purpose of the left and right overbank in the properties of a conduit or channel cross section…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>