Alterar o tamanho do símbolo, a altura do texto ou a largura da linha para elementos num modelo
Luca Santos Billis
Aplica-se a Produto(s): WaterCAD, WaterGEMS, SewerGEMS, SewerCAD, StormCAD, CivilStorm, HAMMER, PondPack Versão(ões): CONNECT Edition, V8i Área: Modelagem Autor Original: Scott Kampa, Grupo de Suporte…
22 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki (Português)
Arch section shape modeling limitations
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm, SewerCAD, StormCAD Version(s): CONNECT Edition Area: Layout and Data Input Problem What are the current limitations and considerations with using the Arch and Pipe-Arch section shapes in…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I know if and when my pond is overtopping and how to quantify it?
Sushma Choure
Product(s): Bentley PondPack, SewerGEMS, CivilStorm Version(s): V8i, Connect Edition Area: Modeling Problem Description How do I know if and when my pond is overtopping? How do I know how much of water is overflowing from…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How does the clogging factor work with catalog inlets?
Jesse Dringoli
Applies To Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): 08.11.03.84 and greater Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem How does the…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Accounting for elevation difference in scaled pipe lengths
Scott Kampa
Product(s): WaterGEMS, Hammer, WaterCAD, SewerCAD, SewerGEMS, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem How can I account for the elevation difference between two nodes in the calculation…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Animating in Profile or Time Browser Very Slow or Causes Hang (Not Responding)
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, HAMMER Version(s): V8i, CONNECT Edition Area: Modeling Problem In certain situations, animating a Profile or the Timestep…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling a Connection to an Existing System
Sushma Choure
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Authors : Scott Kampa, Jesse Dringoli, Tom Walski Background If you are modeling only a portion of a larger…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
The following error occurs with the MicroStation-integrated version a OpenFlows product, like WaterCAD or StormCAD: "Unknown key-in or command".
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 08.11.XX.XX Area: Modeling Problem When opening a MicroStation-integrated version of a product, like WaterCAD for MicroStation…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User Notification - The captured surface flow at this node does not connect a valid subsurface network. The flow is lost from the system.
Jesse Dringoli
Product(s): StormCAD, SewerGEMS, CivilStorm Version(s): V8i, CONNECT Edition Area: Modeling Problem The following Warning message appears in the User Notifications list when computing: The captured surface flow at this…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Limiting conduit design to only certain sizes
Yashodhan Joshi
Product(s): StormCAD, SewerCAD, SewerGEMS Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem How can you limit the design of a conduit so that certain conduit sizes are not included? Solution If you want to put…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I global edit the pipe material and have the roughness update?
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, Hammer Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem How can I global edit the pipe material and have the roughness update…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Select a desired element from overlapping elements
Craig Calvin
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): 08.11.XX.XX and 10.XX.XX.XX Area: Modeling Problem How to select a desired element from a group of overlapping elements…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Property Connection to a Diversion Link
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem When validating a model where a property connection element is connected to a diversion link the following…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User Notifications: "Pump On elevation is not in the range of upstream ...." and "Off elevation of pump is lower than ..."
Jesse Dringoli
Applies To Product(s): SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Description When…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to Batch Morph nodes from one type to another
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm, StormCAD Version(s): CONNECT Edition, V8i SS4 and above Area: Modeling Original Author: Akshaya Niraula, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I input the elevations for an irregular weir cross section in composite outlet structures?
Scott Kampa
Applies To Product(s): SewerGEMS, CivilStorm, PondPack Version(s): CONNECT Edition, V8k Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem Description…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling surcharging of an enclosed storage
Jesse Dringoli
Applies To Product(s): CivilStorm, SewerGEMS, PondPack, WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group …
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User notification: "Conduit has a Stop control structure, but this is not supported next to the connected outfall element."
Sushma Choure
Applies To Product(s): SewerGEMS, CivilStorm, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Description How can the following…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling a vacuum sewer system
Yashodhan Joshi
Product(s): SewerCAD, SewerGEMS Version(s): 08.11.XX.X, 10.XX.XX.XX Area: Modeling Problem Can a vacuum sewer system be modeled using a OpenFlows product such as SewerGEMS or SewerCAD? Solution Designing vacuum sewers…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Extreme Flow Factors (Peaking Factors) in SewerCAD and SewerGEMS
Jesse Dringoli
Product(s): SewerCAD, SewerGEMS Version(s): CONNECT Edition, V8i Area: Modeling Background Extreme flow factors are generally used for computing peak discharges, and therefore are typically referred to as peaking factors…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Unknown Command "<command>" error message occurs when trying to run an operation in Bentley product when integrated with AutoCAD
Larry Abla
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, HAMMER, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Problem "Unknown Command" error message occurs when trying to run an operation in…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error performing standard tasks: "Value does not fall within the expected range"
Scott Kampa
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): 08.11.XX.XX and 10.XX.XX.XX Area: Modeling Problem When performing a standard task the following error message is generated…
28 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error in ModelBuilder: Error: Unable to open table. An item with the same key has already been added
Larry Abla
Applies To Product(s): SewerCAD, SewerGEMS, StormCAD, CivilStorm,WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group…
14 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error opening existing model: "Parameter name: Index was out of range"
Yashodhan Joshi
Product(s): SewerGEMS, SewerCAD, CivilStorm, StormCAD, WaterGEMS, WaterCAD, HAMMER Version(s): 10.00.XX.XX, 08.11.XX.XX Area: Modeling Error or Warning Message When opening a model, the following error message occurs: "Specified…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
No elements or only some of the elements are displayed in the element FlexTables
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
>