Jesse Dringoli
Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Can I customize the annotation table seen at the bottom of the profiles? (the screenshot below shows…
5 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Comparing results between scenarios
Scott Kampa
Product(s): WaterGEMS,WaterCAD Version(s): V8i, CONNECT Edition Area: Output and Reporting Problem Is it possible to compare or visualize results between scenarios for example with annotations? Solution As of version…
9 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Accounting for elevation difference in scaled pipe lengths
Scott Kampa
Product(s): WaterGEMS, Hammer, WaterCAD, SewerCAD, SewerGEMS, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem How can I account for the elevation difference between two nodes in the calculation…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Integration and import / export of Inroads, GEOPAK and Power Civil
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Installation How To: How do the Storm-Sewer products (StormCAD, SewerGEMS, CivilStorm, SewerCAD) integrate with InRoads, PowerCivil…
5 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
FATAL ERROR or Unhandled Exception when opening AutoCAD
Larry Abla
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, StormCAD, CivilStorm, PondPack Version(s): V8i, CONNECT Edition Area: Installation Problem When trying to open AutoCAD one of the following error message occurs…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Intermediate Time Steps
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS Version(s): V8 XM, V8i, CONNECT Edition Area: Modeling Original Author: Dan Iannicelli, Bentley Technical Support Group Problem…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error computing model: Offset and length were out of bounds for the array
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm Version(s): 10.00.xx.xx Area: Modeling Problem When computing a model in SewerGEMS or CivilStorm, the following error message is generated: System.ArgumentException: Offset and length were…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the difference between Darcy-Weisbach roughness coefficients e and f, and Bed Roughness Ks or K?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem Difference between the coefficients e and f , when using the Darcy-Weisbach friction…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Scenario and Alternative Management
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, Hammer, SewerCAD, StormCAD, SewerGEMS, CivilStorm, Pondpack Version(s): CONNECT Edition, V8i or V8 XM Area: Modeling Overview The purpose of this TechNote is to briefly discuss the scenario…
20 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What does the "Rise" in the Design Constraints refer to?
Yashodhan Joshi
Product(s): SewerGEMS, StormCAD, SewerCAD, CivilStorm Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem What is the "rise" when entering the gravity pipe design slope using a table? Solution The…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Plain AutoCAD shortcut is opening OpenFlows product profile
Larry Abla
Product(s): CivilStorm, SewerCAD, SewerGEMS, StormCAD, WaterCAD, WaterGEMS Version(s): CONNECT Edition, V8i Environment: AutoCAD Area: Installation Problem When opening my plain AutoCAD shortcut after opening…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
In the inlet library what is the 'design lengths' used for?
Yashodhan Joshi
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD Version(s): V8i, CONNECT Edition Area: Layout and Data Input Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Unable to meet minimum or maximum velocity constraint
Yashodhan Joshi
Product(s): StormCAD, SewerCAD, CivilStorm, SewerGEMS Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Description No matter what I do I can't get the design run to be within the minimum or maximum velocity…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Pressure engine controls are ignored by the Implicit solver" or "Some pump on/off elevations conflict with Controls..."
Jesse Dringoli
Applies To Product(s): SewerGEMS, SewerCAD Version(s): V8i, CONNECT Edition Area: Other Original Author: Dan Iannicelli, Bentley Technical Support Group Problem When computing a model with…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Pump On/Off Elevations vs. Logical Controls vs SWMM Control sets
Jesse Dringoli
Applies To Product(s): SewerCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Other Problem How are controls configured in SewerGEMS and CivilStorm? (for example to turn a pump on or…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to copy/paste labels for selection sets, named views, and graphs into excel?
Larry Abla
Product(s): WaterGEMS, WaterCAD, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Output and Reporting Problem Where can I find the labels / names for selection sets, named views…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Downloading OpenFlows / Water Infrastructure Software
Larry Abla
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, FlowMaster, PondPack, CulvertMaster, FLOOD Version(s): All Background This article provides information on how to download OpenFlows (water infrastructure…
1 month ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
“Updating conduit descriptions” dialogue when clicked on display inactive topology in options
Larry Abla
Product(s): SewerGEMS, StormCAD, SewerCAD, CivilStorm Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem When trying to turn "display inactive topology" on or off in Tools>Options>Layout, a dialogue…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Properties and flextables will not open in WaterGEMS or SewerGEMS when integrated with ArcGIS
Larry Abla
Applies To Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): CONNECT Edition, V8i Environment: ArcGIS Area: Layout and Data Input Problem Description Properties and flextables will not…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling a side weir conduit control structure
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem I have used the "Side Weir" option in a weir conduit control structure, but it does not appear to be discharging weir outflow away…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Reporting volume of water through certain elements in SewerCAD and SewerGEMS
Scott Kampa
Applies To Product(s): SewerCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem How can I find…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Difference between a "surcharged" and an "overflowing" node
Scott Kampa
Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Output & Reporting Problem What is the difference between the fields “Is Surcharged” and “Is Overflowing" when using the Implicit…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Headloss from Entrance and Exit loss coefficients on a conduit
Larry Abla
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: Calculations Problem I have entered a value for the Exit Loss Coefficient or Entrance Loss Coefficient field in…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the Critical Storm Analysis feature
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition Update 1 and later Area: Output & Reporting Introduction This TechNote explains how to use the Critical Storm Analysis feature, to supplement the information…
5 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Transition Start vs. Warm Start for the Implicit solver calculation options
Larry Abla
Applies To Product(s): SewerGEMS, CivilStorm Version(s): V8i, CONNECT Edition Area: Calculations Original Author: Nancy Mahmoud, Bentley Technical Support Group Problem When should I use…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
>