Using Extreme Flow Factors (Peaking Factors) in SewerCAD and SewerGEMS
Jesse Dringoli
Product(s): SewerCAD, SewerGEMS Version(s): CONNECT Edition, V8i Area: Modeling Background Extreme flow factors are generally used for computing peak discharges, and therefore are typically referred to as peaking factors…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
EPA SWMM solver versions used by SewerGEMS and CivilStorm
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Calculations Problem Which version of the EPA SWMM numerical solver is used by SewerGEMS and CivilStorm, when the active solver is set to "Explicit" in…
6 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Catchment option not available in Modelbuilder when using DXF with polygons
Sushma Choure
Product(s): StormCAD, SewerGEMS, SewerCAD, CivilStorm Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Other Problem I'm using a DXF file in modelbuilder and I don't get the option to make my polygon elements into catchments…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I create a synthetic rainfall curve for a duration other than 24 hours?
Yashodhan Joshi
Product(s): PondPack, SewerGEMS, CivilStorm Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem How can I create a synthetic rainfall curve for a duration other than 24 hours (for example, a 6 hour storm)? Can I use…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Polylines or points show as Polygon in ModelBuilder
Sushma Choure
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): V8i, CONNECT Edition Area: Modeling Problem Why does ModelBuilder show my layer as "(Polygon)" when it should contain…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is it possible to reproject a model to a different coordinate system?
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): 10.xx.xx.xx, 08.11.xx.xx Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem Is it possible to…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Combining models with Submodel Import
Sushma Choure
Product(s): WaterGEMS, WaterCAD, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack Version(s): CONNECT Edition, V8 i and V8 XM Area: Modeling Overview This TechNote will explain how to import one model file (…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the LIKE and IN Operators with queries to filter on text fields such as label
Scott Kampa
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, StormCAD, CivilStorm Version(s): CONNECT Edition, 08.11.05.XX+ Area: Modeling Problem How can I perform advanced SQL queries in the…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Print Preview > Fit to Page shows blank page or Reports will not print
Larry Abla
Product(s): WaterCAD, WaterGEMS, SewerGEMS, SewerCAD, CivilStorm, StormCAD, HAMMER Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Output and Presentation Problem When trying the print a model layout, the "Fit to Page" option…
6 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the WHERE clause and Duplicate option in ModelBuilder to filter imported data
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): V8i, CONNECT Edition Area: Layout and Data Input Original Author: Scott Kampa, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using free form annotations in Element Symbology and Engineering Profiles
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Original Author: Mark Pachlhofer, Bentley…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do OpenFlows product licenses work with element limits? (feature levels)
Jesse Dringoli
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD, WaterGEMS, WaterCAD, HAMMER, PondPack Version(s): CONNECT Edition, V8i Original Author: Mark Pachlhofer, Bentley Technical Support Group …
9 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Why is it that no matter how large the inlet on grade is the gutter spread always remains the same?
Yashodhan Joshi
Product(s): SewerGEMS, CivilStorm, StormCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Why is it that no matter how large the inlet on grade is the gutter spread always remains the same? Solution…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I reverse the start and stop node for a pipe, conduit, gutter, etc...?
Yashodhan Joshi
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Data Input and Modeling Problem How do I reverse the start and stop node for a pipe…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Downstream Trace and Digital Terrain Models
Jesse Dringoli
Product(s): StormCAD, SewerGEMS, CivilStorm, SewerCAD Version(s): CONNECT Edition, V8i SELECT Series 4 (08.11.04.54) and later Area: Modeling Background The ability to attach Digital Terrain Models and the Downstream Trace…
15 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I label my contours when using the AutoCAD platform?
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Problem How do I label my contours when using the AutoCAD platform? When generating a contour for my…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to manually check in a license
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, CulvertMaster, FlowMaster Version(s): All Area: Licensing Original Author: Jesse Dringoli, Bentley…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do you create IF / THEN / ELSE statements using Formula-derived user data extensions?
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling an Ideal Pump (Outflow matches Inflow)
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm Version(s): As of 10.01.01.04 Area: Modeling Problem Is it possible to model an "Ideal" pump, where the outflow from the pump will match the inflow? This might be used for example…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do each of the LoadBuilder methods work?
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Authors: Jesse Dringoli, Dan Iannicelli, Bentley Technical Support How do each…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the Flow Monitoring Distribution method in LoadBuilder
Scott Kampa
Applies To Product(s): SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Layout and Data Input Original Author: Jesse Dringoli, Bentley Technical Support Group Overview This TechNote…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do you direct flow from a channel or pipe into a pond?
Jesse Dringoli
Product(s): PondPack, CivilStorm, SewerGEMS, SewerCAD, StormCAD Version(s): V8i, CONNECT Edition Area: Modeling Problem How do you direct flow from a channel or conduit into a pond? Solution Place an outfall element at…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What do the different "width" and "length" fields represent, for a catalog inlet?
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): 08.11.XX.XX, 10.00.00.XX Area: Calculations Problem What do the different "width" and "length" fields represent, for a catalog inlet? How are inlet structure…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to create a Selection Set
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Problem How to create a selection set? Solution - Manual Creation Use the steps…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Road slope vs. Gutter slope vs. local depression
Jesse Dringoli
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD Version(s): 08.11.XX.XX Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem What is the difference…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>