Yashodhan Joshi
Product(s): StormCAD, SewerCAD, SewerGEMS Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem How can you limit the design of a conduit so that certain conduit sizes are not included? Solution If you want to put…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the difference between a parallel and perpendicular 'area orifice' orientation in the composite outlet structure?
Jesse Dringoli
Applies To Product(s): SewerGEMS, CivilStorm, PondPack Version(s): 08.11.XX.XX Area: Layout and Data Input Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I set a certain slope for my pipes when designing them?
Yashodhan Joshi
Product(s): SewerGEMS, CivilStorm, SewerCAD, StormCAD Version(s): 08.11.XX.XX Area: Modeling Problem How can I set a certain slope for my pipes when designing them? (fixed slope / known slope) Solution If you would…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Creating Custom Reports
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition Area: Output and Reporting Background Starting with the CONNECT Edition, you can now create custom reports that…
6 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Sharing Hydraulic Model Files on the OpenFlows | Hydraulics & Hydrology Forum
Larry Abla
Product(s): SewerGEMS, WaterGEMS, StormCAD, SewerCAD, CivilStorm, WaterCAD, PondPack, FlowMaster, CulvertMaster, OpenFlows Flood Version(s): Varies When posting on the OpenFlows (Haestad) | Hydraulics and Hydrology forum , providing…
3 months ago
About Bentley Communities
Communities Help Wiki
LandXML Terrain Model does not obey boundary lines
Jesse Dringoli
Product(s): StormCAD, SewerGEMS, CivilStorm Version(s): 10.00.00.40 Area: Layout and Data Input Problem When using a LandXML file in the Terrain Model tool, the boundary lines are not respected. Contour lines are shown beyond…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Quick Graph
Craig Calvin
Product(s): SewerGEMS, CivilStorm, SewerCAD, WaterGEMS, WaterCAD Version(s): 10.00.00.XX and later Area: Output and Reporting Introduction The quick graph feature allows you to quickly view a graph of a single element…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the difference between using ArcMap or ArcGIS Pro and using the integrated versions?
Scott Kampa
Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): CONNECT Edition, V8i Environment: ArcGIS Pro, ArcMap Area: Help and Documentation Problem What is the difference between using the WaterGEMS or SewerGEMS for…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Opening an existing hydraulic model when integrated with ArcMap or ArcGIS Pro
Jesse Dringoli
Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): CONNECT Edition, V8i Environment: ArcMap, ArcGIS Pro Area: Modeling The steps below will show add an existing hydraulic model while working in the ArcMap or ArcGIS…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling Property Connections in the Storm-Sewer products
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm, SewerCAD, StormCAD Version(s): 10.00.00.40 and later Area: Layout and Data Input Introduction The Property connection element was introduced in the CONNECT Edition (10.00.00.40) and is used…
4 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
The program hangs when opening a model or switching scenarios
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Performing clash detection of storm sewer and water hydraulic models
Yashodhan Joshi
Product(s): SewerCAD, SewerGEMS, WaterCAD, WaterGEMS, CivilStorm, StormCAD, HAMMER Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem: Is it possible to perform clash detection (otherwise known as Conflict Resolution…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Center-to-center vs wall-to-wall length and slope calculations
Jesse Dringoli
Product(s): StormCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): V8i, CONNECT Edition Area: Calculations Problem Are pipe lengths and slopes based on the center-to-center distance between the structures, or based on edge…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What does it mean if a pipe's flow is negative?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, CivilStorm, StormCAD, SewerCAD, PondPack Version(s): V8i, CONNECT Edition Area: Calculation Problem What does it mean if the calculated flow in a pipe is negative? Solution…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Units for V-notch vs rectangular vs irregular weir
Yashodhan Joshi
Product(s): PondPack, SewerCAD, SewerGEMS, CivilStorm Version(s): 08.11.XX.XX Area: Layout and Data Input Problem What is the difference between the weir coefficient with a v-notch versus other weir types? What…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to register DAO360.dll or a dll file?
Luca Santos Billis
Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): 08.11.03.83 and 08.11.03.77 (for Storm and Sewer products); build 08.11.03.19, 08.11.03.17, and 08.11.03.16 (for Water products) Area: Installation…
15 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Exporting profiles to .DXF files
Sushma Choure
Product(s): StormCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): V8i, CONNECT Edition Area: Output and Reporting Problem How can a profile be viewed in AutoCAD, to do some additional formatting for reporting purposes? Can…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Exporting profiles to PDF, Excel and Image formats
Douglas Miranda
Applies To Product(s): StormCAD, SewerGEMS, SewerCAD, CivilStorm, HAMMER Version(s): V8i, CONNECT Edition Area: Layout and Data Input Original Author: Scott Kampa, Bentley Technical Support Group …
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What does the user notification "Conduit has adverse slope" mean in the storm and sewer products
Larry Abla
Product(s): StormCAD, SewerGEMS, CivilStorm, SewerCAD Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Calculations Problem What do the user notifications "Conduit has adverse slope" or "Link slope is zero" mean? Solution The…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I global edit the pipe material and have the roughness update?
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, Hammer Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem How can I global edit the pipe material and have the roughness update…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What's New in SewerGEMS V8i SELECTseries 3?
Yashodhan Joshi
Product(s): SewerGEMS Version(s): 08.11.03.77 Area: N/A Overview The SELECTseries 3 release of SewerGEMS includes many new features and improvements. Let's explore each of these in detail. -Support for Newer Platforms and…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Understanding the Modified Rational Method
Jesse Dringoli
Product(s): CivilStorm, PondPack, SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Overview The purpose of this technote is to clarify how the Modified Rational Method works, how it differs from the Rational…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Paging file is too small for this operation to complete
Sushma Choure
Product(s): SewerGEMS, SewerCAD, CivilStorm, StormCAD Version(s): 08.11.XX.XX Area: Calculations Problem When trying to compute a model, the following error occurs: "The paging file is too small for this operation to complete…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
WaterGEMS for ArcGIS Pro and WaterGEMS for ArcMap FAQs
Jesse Dringoli
Product(s): WaterGEMS, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Training / videos Building a model from a Geodatabase with ModelBuilder in ArcMap Assigning Demands using LoadBuilder in ArcMap Assign elevations…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Software is running in disconnected mode
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, Hammer,StormCAD, SewerCAD, CivilStorm Version(s): 08.11.01.32 Area: Licensing Problem After checking out a license, I open the software and this message pops up: "Software…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>