Can the storm-sewer products perform a transient analysis in the sewer force mains?
Jesse Dringoli
Applies To Product(s): SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem Can the storm-sewer products…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
System.FormatException: Input string was not in a correct format
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 10.00.XX.XX, 08.11.XX.XX Area: Output and Reporting Problem The following error message is generated when computing…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How is the wet well Depth (Node) field calculated?
Jesse Dringoli
Product(s): SewerGEMS Version(s): 08.11.05.113 Environment: N\A Area: Output and Reporting Subarea: N\A How is the wet well Depth (Node) field calculated? For the GVF-Convex solver: Depth…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What does the user notification "Conduit has adverse slope" mean in the storm and sewer products
Larry Abla
Product(s): StormCAD, SewerGEMS, CivilStorm, SewerCAD Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Calculations Problem What do the user notifications "Conduit has adverse slope" or "Link slope is zero" mean? Solution The…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Sanitary loads are not being applied
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD Version(s): N\A Environment: N\A Area: Modeling Problem After computing a model that contains manholes with sanitary loads, the result field "Flow (System Sanitary)" reports…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is a drop manhole and how do I model one?
Luca Santos Billis
Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: General Problem What is the Difference Between a Drop Manhole (drop structure) and a Regular Manhole? How do I create a drop structure…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What’s new in StormCAD, SewerCAD, SewerGEMS and CivilStorm V8i SELECTseries 5 with CONNECT Integration?
Yashodhan Joshi
Product(s): Bentley SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 08.11.05.113 Area: N/A Table of Contents Introduction A Note on Model Version Compatibility Patches CONNECT Integration Informational…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
When running a query, why is it not picking up the elements that it should?
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, StormCAD, CivilStorm, HAMMER Version(s): CONNECT Edition, V8i Area: Other Subarea: N\A Defect Description…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Why does the profile for the system appear to be at odds with the results for the capacity?
Yashodhan Joshi
Applies To Product(s): StormCAD, SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Calculations Original Author: Scott Kampa, Bentley Technical Support Group Problem Description Why does…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Morphing conduits into pressure pipes
Yashodhan Joshi
Product(s): SewerCAD, SewerGEMS, CivilStorm, StormCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem Is it possible to change or morph a conduit into a pressure pipe or vice versa? Solution There are ways to…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Compacting data causes element display issues
Scott Kampa
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, HAMMER, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to create and share FlexTables between different computers
Jesse Dringoli
Applies To Product(s): StormCAD, WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, HAMMER, PondPack Version(s): CONNECT Edition, V8i Area: Output and Reporting Original Author: Scott Kampa, Bentley Technical…
4 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to model a swale in the storm and sanitary products
Jesse Dringoli
Product(s): StormCAD, SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem What is the best way to model a swale in the storm and sanitary products? Solution Assuming the swale is similar…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error message in AutoCAD integrated version: "FATAL ERROR: Cannot write to undo file (probably disk full)"
Yashodhan Joshi
Applies To Product(s): Bentley SewerCAD, Bentley SewerGEMS, Bentley CivilStorm, Bentley StormCAD Version(s): 08.11.03.77 Environment: N/A Area: Calculations Subarea: Original…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error message generated when loading background file
Larry Abla
Product(s): CivilStorm, SewerGEMS, SewerCAD, StormCAD Version(s): 08.11.xx.xx Area: Modeling Problem Description When trying the load a shapefile as a background file, the following error message is generated: "Object reference…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<