Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
SewerGEMS
StormCAD
AutoCad
CivilStorm
CulvertMaster
DXF
error message
FlowMaster
HAMMER
installation
licensing
MicroStation
Migrated
ModelBuilder
Modeling
OpenFlows
PondPack
Profiles
Reviewed2016
reviewed2017
Reviewed2018
Reviewed2019
SELECTsupport
SewerCAD
training
WaterCAD
WaterGEMS
Is it possible to delete an element from one scenario, but retain it in another?
Jesse Dringoli
Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"The outlet structure's entered minimum headwater elevation X ft is greater than or equal to the entered maximum headwater elevation X ft..."
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS, OpenRoads Designer Version(s): CONNECT Edition Area: Layout and Data Input Problem When attempting to compute a model, the following User Notification appears and the calculation…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User Notification "The controls in the conduit are ignored by this solver"
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS, OpenRoads Designer, OpenSite Designer Version(s): CONNECT Edition, V8i Area: Calculations Problem When computing a model with the GVF-Convex (StormCAD) solver, the following user…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error Installing: "Error 1935. An error occurred during the installation of assembly"
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Installation Problem When installing a Bentley Hydraulics and Hydrology…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error exporting storm-sewer model to Micro Drainage – Labels do not contain pipe numbering in the correct format
Sushma Choure
Product(s): Bentley SewerGEMS, CivilStorm, StormCAD Version(s): V8i, Connect Edition Area: Output and Results Problem Error on exporting storm-sewer model to Micro Drainage – Labels do not contain pipe numbering in the correct…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is there a way to hide unwanted columns in conduit catalog?
Jesse Dringoli
Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem How do I hide unwanted columns in conduit catalog? While adding a new catalog class in the conduit…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Deleting multiple patterns (bulk delete)
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD, Version(s): CONNECT Edition Area: Modeling Problem I have a large number of patterns in my model that I need to delete. The pattern manager does not allow me to multi-select. How can I batch…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error opening .STM file - ERROR: Jet Error #3265 Item not found in this collection. Unable to start StormCAD.
Scott Kampa
Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): CONNECT Edition Area: Modeling Problem When trying to open a .STM file, the following error is generated: ERROR: Jet Error #3265 Item not found in this collection. Unable…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Storm Water Calibration Tips
Sushma Choure
Product(s): Bentley StormCAD, CivilStorm, SewerGEMS Version(s): V8i, Connect Edition Area: Results and Outputs Background The purpose of this article is to provide guidelines and best practices for hydraulic model calibration…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to troubleshoot system deficiencies in a hydraulic model, like flooding, low pressures, or tank or pipe size
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, HAMMER Version(s): CONNECT Edition Area: Modeling Background OpenFlows applications have a wide range of use in modeling a water or storm…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to remove bends from a pipe or conduit
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, CivilStorm, StormCAD, SewerCAD, HAMMER Version(s): CONNECT Edition Area: Modeling Problem Is it possible to remove bends from a pipe or conduit? Solution You can right-click…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I reverse the profile view?
Scott Kampa
Product(s): SewerCAD, SewerGEMS, StormCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem How can i reverse the direction of profile view? Problem ID#: 41748 …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error message: "Unrecognized database format ..." when trying to open model
Jesse Dringoli
Applies To Product(s): FlowMaster, WaterCAD, WaterGEMS, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Original Author: Mark Pachlhofer, Bentley Technical Support Group…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Customizing element properties grid with Property Grid Customizations
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, SewerGEMS, CivilStorm, StormCAD, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem There are too many fields visible in the element properties window. Can…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Distorted graphics in SewerGEMS installed on Dell Alienware computers
Yashodhan Joshi
Product(s): SewerGEMS, WaterGEMS, HAMMER, SewerCAD, StormCAD, CivilStorm, WaterCAD Version(s): 10.XX.XX.XX Area: Other Problem SewerGEMS (or other products) icons in the ribbon menu and workflows appear distorted. Solution…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Group editing option on right click
Larry Abla
Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): 10.03.04.53 Area: Layout and Data Input You can edit the properties of a Selected group of items. To do this, Create a Selection Set consisting of those items…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Catchment Width higher value
GANESH BALA S
Greetings, This is Ganesh, currently i am working in a Urban drainage project. I am using EPASWMM Runoff method in which i am facing issue in one catchment(refer below properties in image). Actual Width of this catchment is 349 meters but the model…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Windows 11 Compatibility for OpenFlows Products
Larry Abla
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, FlowMaster, CulvertMaster, FLOOD Version(s): CONNECT Edition Area: Installation Problem Are the OpenFlows products compatible with…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error message when validating model: "Elevation (Relative) values within the Irregular shape definition must be non-negative."
Sushma Choure
Product(s): Bentley CivilStorm, SewerGEMS, SewerCAD, StormCAD Version(s): 08.11.xx.xx, 10.XX.XX.XX Area: Modeling Error or Warning Message When computing or validating a model, the following error message is generated: …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User notification: "Link diameter (or rise) is smaller than the diameter (or rise) of the upstream"
Scott Kampa
Product(s): StormCAD, SewerCAD, SewerGEMS CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem When computing or validating a model, the following user notification is generated: "Link diameter (or rise) is…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Sorting by label is not in the expected order
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, StormCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Problem When sorting an element FlexTable based on the label, the order of the elements is…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
MicroStation CONNECT Edition crashes when laying out new elements
Jesse Dringoli
Product(s): StormCAD, SewerCAD, SewerGEMS, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): 10.03.04.53 (storm & sewer), 10.03.05.0X (water) Area: Layout and Data Input Problem When attempting to lay out or move an element…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
An older storm-sewer model file, such as a .STC file, doesn't appear when importing into the MicroStation-integrated version of the products
Scott Kampa
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition, V8i SELECTseries 4 or later Environment: MicroStation Original Author: Mark Pachlhofer, Bentley Technical Support Group…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Understanding the "Boundary Condition Type" for an Outfall
Larry Abla
Product(s): SewerGEMS, SewerCAD, StormCAD, SewerCAD Version(s): CONNECT Edition Area: Modeling Problem What is the "Boundary Condition Type" for an outfall and what do each of the options mean? Solution The "Boundary…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
OpenFlows product menus missing or not working from Ribbon interface for MicroStation CONNECT Edition integrated version
Sushma Choure
Product(s): SewerGEMS, StormCAD, SewerCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition Update 3 (10.03.04.xx or later) Area: Installation Environment MicroStation CONNECT Edition Problem …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>