  • How CAN & DFF Parameter works in Staad Pro ?

    Hello Team, I am working on a design where the platform is connected to vertical pressure vessel, and framing members are cantilevers. Assigning CAN 1 and DFF 300 parameters to the whole structure -- I want to understand how these parameters are used…
  • Seismic Forces are not getting evaluated correctly ?

    I am working on a platform structure, Which is located on the vessel the height from base is approximately 2.5m I have assigned the seismic forces using the seismic definition option from staad but the forces are not getting assigned correctly, If I visualize…
  • Report Tab Not Visible

    I have recently Installed Staad Pro and I am not able to view the report Tab see below snip, How I can turn it on? I am using STAAD.Pro 2023 - Version 23.00.01.25
  • LY LZ Bending Diagram

    Hello, I have assigned the parameter for LY LZ to the beams see below Image, this beam has node to node distance of 100mm as this is a stiffening beam for plate elements. Now I want to verify the bending behavior is happening correctly on the basis of…
  • Deflection not appearing in staad output file

    I'm having a problem with mu model. How would I make the deflections appear in the staad output file? All I am getting are these I am checking for strength and serviceability check. Load Envelope 1 for Srength and Load Envelope 2 for serviceability…
  • How to find user connection database folder in Connection Design using STAAD PRO Connect?

    Is it possible to share the user connection database in Connection Design using STAAD PRO Connect? I'm trying to find a user connection database file location, which I need to share my connection database (created by the user) to the team. My purpose…
  • Why does STAAD Aluminum Design report fail to give any output in the "Clause" or "L/C" columns in the Utilization Ratio chart.

    Please help! Designing a simple truss using the Aluminum Code analysis. The initial analysis produced utilization ratios where the "Clause" references AISC's H1-3 Equation and H2-1 Equation. This led to revise my analysis commands so that it was analyzing…
  • STAAD PRO connect edition to RAM connection stand alone

    Hi, We recently purchased the license for RAM connection stand alone and we are using STAAD PRO connect edition V22 Update 6 for analysis but without having an access to integrated RAM connection design found in STAAD PRO. Hence, the structural analysis…
  • Mat Foundation Design - STAAD Foundation Advanced Error

    Hello. Good day! I was designing a mat foundation at STAAD Foundation Advanced and it cannot give a "PLOT Failure Diagram". Further, it will give an error message saying "The bar arrangement provided corresponds to a steel area that is less than the…
  • STAAD.pro Structural Tooltip Options

    Dear colleagues, i haven't noticed this before, but recently i had applied more than 3 releases to a member and i noticed that the Structural Tooltip popup (yellow) shows only the first 3 releases and skipped the rest. Structural Tooltip has always…
  • Properties of WF doesnt make sense.

    Anyone can help... My properties of WF doesnt make sense. I have a beam of 1000 mm, but the properties of WF are far below 0.0 mm like this. Maybe there is a solution to my problem?
  • Question regarding StaadPro CE file

    Hello everyone, I am modeling a steel joists truss in Staad pro CE but I am having trouble on how to resolve the warnings and errors. I have a double angle for the top chord and custom section properties for the bottom chord since staad did not have…
  • composite damping or spring damping

    Hello, is there an example for how to use composite damping or spring damping? i am doing a dynamic analysis for a group of vertical pumps being mounted on top of underground tank. i want to consider the soil material damping using composite damping…
  • Connecton

    Hi, I 'd like to design a beam - column connection with a fin plate welded to CHS column and bolted to the web of a UC. Is it something that can be done using the built in connections design tool in Staad pro because I didn't manage to find it as…
  • load assigning problem in the staad .

    I am working on a G+2 public steel building, after modeling I am unable to assign the load on LL.acn anybody rectifies this problem? all the loads assigned are done by old v8i staad pro , but in connect edition this load is not working properly. in the…
  • STAAD Pro Version 22.10.00.153

    WE HAVE TRIED WITH THE FOLLOWING AVAILABLE COLD FORMED SECTIONS: Angle With Lips - 1 Double Angle (LD) Double Angle(SD) Channel With Lips Channel Without Lips Double Channel Back to Back Double Channel Front to Front Zee With Lips …
  • Staad Purlin's design was all about failure.

    PEB warehouse structures Please, solve We have been trying to build a PEB staad.pro model of a warehouse for the past several days. We have set up all the IS standards of property and loading settings we know. However, the economic conclusion…
  • Cannot Select Design Parameters Drop Down List

    Hi! I am a newbie user of STAAD PRO Connect Edition. I received from my senior some Staad Model that I need to review. It has 4 Design Parameters that checks different loading conditions and design checks. Unfortunate in the Post Process > Results…
  • STAAD Pro "steel design detail" no longer able to show specific selected beam

    I am using STAAD Pro CONNECT Edition v22. After the update, the "Steel Design Detail" in the Report no longer able to select to show specific selected beam. Instead, the report lump every single member design detail in one like below: In previous…
  • STAAD PRO CONNECT - Plate Overhang

    Hi all, I want to know if it is possible to have a plate overhang my beams. The overhang will be 0.3m in the Z direction on both sides. I have tried everything I can think of but I cannot illustrate the plate accurately. When I try to mesh one large…
  • How to change the shear reinforcement number of leg and bar size in RCDC

    the beam has failed in shear so i need to change the bar size and no. of legs, How to change the shear reinforcement number of leg and bar size in RCDC,
  • STAAD Pro splash screen stays in "finalizing".

    My Staad won't open, it stays forever in the splash screen. I've done everything. Update it, uninstall it, install again the V8. but anything works. My license is okay, and everything seems just fine. Before, it would open in just a few secs. I have rename…
  • STAAD CONNECT - Variance In Length by 0.00001 m

    Hey All, While Modelling A Building In Staad Connect Edition, When I Model A Slab Of 5 X 5 m Size In C.E., It Takes The Length As 5.00001 m Irrespective of 5m Length Input, And So It Gives Error While Generating Floor Load With Boundary Of 5 X…
  • Warning - This structure is disjointed - Staad Pro Connect

    Hello, I am seeking help with connecting my base plates to my structure frame. I receive the warning " Warning - This structure is disjointed " and I believe it is because my plate and structure are not connected properly. How do I do so? I have been…
  • Plate Overhang - Staad Pro Connect

    Hello, How can I make my plate overhang the beams beneath AND cover the full flange on the end beams? Does this require the plate to be offset in the X direction? Any help would be really really appreciated. Thanks.