Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
Steel Design
Eurocode
ASIC 360-10
concrete
connection tags
design
DXF
EC3
EN 1993-1
Eurocode 3
LTB
RAM Connection
RAM Frame
RCDC
seismic
SELECTsupport
SIG
STAAD
staad pro v8i
STAAD.Pro
STAADPro
Steel
Structural
structural engineering
training
Virtual
webinar
Designing Steel Structures in STAAD.Pro
Sabrina Tedeschi
STAAD.Pro can design steel structures for a variety of US and International design standards : Available Steel Design Codes Designing Steel Structures - On Demand Training Learn how to design steel structures in STAAD.Pro CONNECT Edition. Download…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Mton/Cm to Kn/m
Sulaiman Ade
How do I change Mton/Cm to Kn/m
Answered
over 3 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Eurocode with German NA
Nirav Thakkar
Hello, Currently, I am using STAAD pro Connect edition's latest version. Following are question mainly targeting of RCC and Steel structure design in STAAD Pro and in other Bentley tools per Eurocode with German N ational Annex (NA). 1. Can…
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Bi-axial bending and torsion EC3
Ibrahim Kadri
Hello everyone, I have a question about the bi-axial bending and torsion calculations in StaadPro based on EC3. I designed a beam (RHS) subjected to bi-axial bending and torsion. I am comparing my hand calculations with Staad pro unity check but…
Answered
over 4 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
SIG Virtual Workshop: STAAD for EMEA - July 26, 2018 - You're Invited!
Patsy Gant
Please join Bentley's Badreddine Ziane and Richard Tully for the first virtual workshop of the STAAD for EMEA Special Interest Group (SIG) on Thursday, July 26, 2018 at 11 a.m. CEST. Discussion will focus on how to best leverage your STAAD software for…
over 5 years ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Announcements Forum
LTB check EN 1993-1 on cantivered section
Inigo Salazar
Hi, I'm carrying out an LTB check to a 5 metre long cantilevered column as per EN 1993-1. I found a way to carry out the check by setting the CMM parameter to 7 (or to 8) and then manually specifying C1, C2, C3 and ZG as per NCCI SN003b (or similar…
over 7 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
STAAD.Pro EN 1993-1-1:2005 Implementation: Elastic Verification of Cross Sectional Resistance
Modestas
Applies To Product(s): STAAD.Pro Version(s): All Area: Steel Design Subarea: EN 1993-1-1:2005 Original Author: Sudip Narayan Choudhury, TSG (Structural), Bentley Kolkata …
6 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Staad Pro - Critical moment calculation according to Eurocode 3
Pedro Machado
Hi everyone! I am analysing a Channel section according to Eurocode 3 and I am finding it hard to understand how Staad calculates the critical Moment (Mcr) The critical moment I get from the program is different from the one I get from "Annex F of…
Answered
over 9 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Column Stiffeners: More Options in RAM Connection
Ann Marie
Come and visit RAM Inside OUT, by Ann Marie Garko-Hill, PE ! The most recent post will explain all the column stiffener options in RAM Connection . I am interested in your questions or modeling conundrums. Is there a feature you want to know…
over 10 years ago
RAM | STAAD | ADINA