  • hi everyone, can anybody help me to solve this model because have error of the snow and seismic loads??

    STAAD SPACE START JOB INFORMATION ENGINEER DATE 30-Nov-22 END JOB INFORMATION INPUT WIDTH 79 UNIT MMS KN JOINT COORDINATES 55 468.544 16072.7 192.577; 73 507.061 16072.7 -1.061; 107 358.857 16072.7 356.735; 151 7030.99 14763.7 2911.01; 152 7609.76 14763…
  • RAM Frame and NBCC 2015 4.1.8.11 4)

    Hi, Based on NBCC 2015 4.1.8.11 4) single storey buildings with steel or wood deck as diaphragms can have a higher fundamental period compared to 4.1.8.11 3) as seen in the snap below. However, in the current RAM frame the Ta is only based on clause…
  • Steel member design - Staad Pro SS6 edition

    In STAAD Pro SS6 edition (Version 20.07.11.70) when a member subjected to Combined Axial force and bending, the member fails with higher ratios (i.e., 200, 216584 etc. ) according to section 9.3.1.1 as per IS 800 - 2007 (LSD). But when I calculate manually…
  • Having Doubt in STAAD Seismic Analysis for New Zealand Project

    Currently Working on Pipe rack Design for the New Zealand site. And I want to do Seismic analysis for the pipe rack. I have seen the seismic code list which is available in software. New Zealand Seismic code is not available in code list then how we can…
  • The analysis of a stepped column is possible or not?

    PDF Dear communities, Please provide me the solution or method to design & analysis the STEPPED column. For the reference, I have attached the pdf file, please check it & provide me the solution. Thank you.
  • Mton/Cm to Kn/m

    How do I change Mton/Cm to Kn/m
  • RAM Elements CONNECT Edition v16.2 Release Notes

    RAM Elements CONNECT Edition v16.02.00.88 Release Notes – Updated July 2020 Enhancements : 1. New options to automatically mesh members to perform P-δ analysis. The analysis dialog now includes two options to configure how the members will be automatically…
  • Steel Structures Optimization of Members is not increasing member sizes to make them pass, using Indian code IS 800-2007 LSD

    Steel_Design_Optimizing_M_Intermediate_1_AISC_360-16.STD Steel_Design_Optimizing_M_Intermediate_1._IS800-2007 LSD.STD Why I am getting "Fail" results after using optimization process of commands?; even selecting Ratio 0.9 initially, e.g look into…
  • STAAD Webinar: Have no fear, Steel AND Concrete are here!

    It’s easier than ever before to take your project from analysis and design to automated drawing and documentation. Produce the bill of materials and gain instant insight into various design alternatives for the most cost-effective design. Please join…
  • RE- Openstaad modelling learning

    Dear Team, How to start learning Openstaad from scratch level to advance level for automation of steel design , do we have any complete tutorials in bentley or any other videos comfort content is available . which programming language is usefull for…
  • Saad Pro

    I s there any way in Staad pro to design slim floor beam SFB where the Slab floor rests on the lower flange
  • How Does STAAD V8i SS6 Read .UPT Files?

    Hello all, I am working on a structural analysis for an existing structure where I've needed to model ST6 I 15.9 members (AISC-360, 7th Edition). Because this a very uncommon section that is not in the Section Database, I've instead added it through the…
  • Problem modelling plates on top of beams for elevated steel water tank

    I am trying to model a Elevated steel water tank with bracing for analysis in STAAD.Pro. While modelling the structure I've encountered a problem and would like your help. The problem is: While the beam offset works perfectly for modelling a beam…
  • Member Design Failed for member in steel structure and also Members get failed in output file

    I have designed a steel structures in staad pro. I have some doubts in below 1. I'm getting an error in member designed failed, how to resolve it. 2. In output, Some of my members gets failed and some gets pass how to resolve it and how to optimize…
  • UC Ratio problem

    warehouse.zip wind calculation also in that folder.... try to fix this probem guys
  • WARNING: THE VALUE OF MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4

    We are facing the following warning in designed steel structure as per IS 800:2007(WSD). ***WARNING: THE VALUE OF MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4" Kindly suggest the removal process.
  • how to get the loadings details in report????

    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
  • Barras armadas comprimidas Grupo IV y V

    Hola; Necesito saber si es posible generar barras según las define el reglamento CIRSOC 301, como Itipo Grupo IV y Grupo V en RAM, como se ven en la imagen del link. https://www.google.com.ar/url?sa=i&rct=j&q=&esrc=s&source=images&cd=&ved=2ahUKEwjp8…
  • RAM Elements CONNECT Edition v16.0 Release Notes

    RAM Elements CONNECT Edition v16.00.00.37 Release Notes – Updated December 2018 Enhancements : 1. New CONNECT Licensing which is Bentley’s new process for product activation that allows the user better control over their usage. Please click here…
  • Class 4 sections in RAM Frame

    Product(s): Ram Structural System; Ram Frame Version(s): V8i Environment: N/A Area: Design Original Author: Bentley Technical Support Group British Sections designed, in RAM Frame, in accordance…
  • Limcon

    Limcon is productivity-geared steel connection design software. Connection types include beam to column, brace end, member splices, anchorage to concrete, and complicated multi-member joints. By using a library of standard connection types, designers…
  • Free Seminar! RAM Insider Skills Special Interest Group

    FREE Live Seminars to sharpen your skills. The Insider Skills - Special Interest Group series is offered weekly. RAM is featured on week 4 of each month. Join us Thursday July 24th! Please Note: Starting in July we will change to Thursdays…
  • Job opportunities in Qatar for engineers

    A prestigious public company in Qatar is hiring engineers : They urgently require the following professionals- MINIMUM 7 YEARS EXPERIENCE DESIGN DRAINAGE Foul Sewer Engineer Hydrologist Senior Planning Engineer Senior…
  • RAM Structural System V8i Release 14.04 New Features and Enhancements

    Version 14.04 of the RAM Structural System V8 i is scheduled to be released July 2011. This version contains several significant enhancements. Some of these are listed below. Hanging Columns The ability to model, analyze and design hanging…
  • Column Stiffeners: More Options in RAM Connection

    Come and visit RAM Inside OUT, by Ann Marie Garko-Hill, PE ! The most recent post will explain all the column stiffener options in RAM Connection . I am interested in your questions or modeling conundrums. Is there a feature you want to know…