Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
Steel Design
analysis
Bentley Structural
Concrete Design
CONNECT Edition
design
Eurocode
Eurocode 3
RAM
RAM Concept
RAM Connection
RAM Elements
RAM Frame
RAM Structural System
STAAD
STAAD analysis
Staad pro
staad pro v8i
STAAD.Pro
STAAD.Pro CONNECT Edition
STAAD.Pro V8i
STAADPro
staadpro v8i
Steel
Structural
structural engineering
Steel member design - Staad Pro SS6 edition
Vishnu Mani
In STAAD Pro SS6 edition (Version 20.07.11.70) when a member subjected to Combined Axial force and bending, the member fails with higher ratios (i.e., 200, 216584 etc. ) according to section 9.3.1.1 as per IS 800 - 2007 (LSD). But when I calculate manually…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RAM Elements Learning Resources
Sabrina Tedeschi
RAM Elements is a finite element-based general analysis program with an integrated design toolkit. In RAM Elements, you can design complex three dimensional structures or individual structural components. In the RAM Elements main application, a model…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Large rotational displacement in Node.
sandesh D
PR-1_24072022.STD I applied Moment along Mx direction. due to that i found rotational displacement with large amount. Also note i have specie as Truss. Attached model for reference. if any mistake by me please suggest.
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Difference in Compressive & Tensile stress values for a symmetrical I beam which is connected to a vertically restrained plated structure and subjected to UDL
FAISAL K E
Hi, I was doing a case study for the combined beam & plate effect in STAAD Pro using AISC ASD. 2 geometries were prepared; 1. A simply supported beam subjected to 1kN/m UDL 2.A simply supported beam with plate structure bottom vertically restrained…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Regarding Lx parameter value.
KRISHNARAJ POIYAMOZHI
How to give the design parameter of Lx(lateral torsional buckling) For column member. In my case, The column height is 12m, Minor axis direction tied at each 3m. But major axis direction not tied. What is the Lx parameter value?
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RAM Elements existing PEMB analysis always fails
Jack Worline
We often need to analyze existing PEMB structures and when only existing loads are applied the structure still fails. We have used the MBMA special considerations option in our design and that does not seem to help. What are we missing? Is there another…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Steel design output are not shown for some properties
S A
8037.Shelter 1.std Hi, In my model some properties Steel design output are not shown in Results. I have attached model for your reference. I'm using latest STAAD connect edition.
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Steel Beams with low compressive force failing in slenderness
manmohit singh
In a steel frame structure I am modeling, For one row of beams allowable slenderness is 400 (fx = -0.005 kN) For similar second row of beams allowable slenderness is 180 (fx = 0.005 kN) and it is failing. This minuscule compressive load is making…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Uplift point loads in my model are not being considered by the ram beam design module
Kyle Gerard
I have a building with screen wall loads on the roof. These loads act as a couple with the main post and the kicker having reactions in opposite directions. When I add these loads to the ram model, ram beam module is only considering the downward gravity…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Does anyone know how can we model HSS with uneven width in RAM Elements?
Aashish
I'm trying to model HSS with different widths at its end. But I do not have any idea how to model it in RAM Elements. If anyone has a solution for this, please let me know. Thank you in advance. A section like this.
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Having Doubt in STAAD Seismic Analysis for New Zealand Project
Suraj Jadhav
Currently Working on Pipe rack Design for the New Zealand site. And I want to do Seismic analysis for the pipe rack. I have seen the seismic code list which is available in software. New Zealand Seismic code is not available in code list then how we can…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Steel Design Parameters in Modeller
RFreund
I assume this has been mentioned before (might even be working on it), but being able to specify the steel design parameters in the Modeler would be a game changer. A separate design module would be good too, but I don't think it's necessary.
over 1 year ago
RAM | STAAD | ADINA
STAAD.Pro
Designing Steel Structures in STAAD.Pro
Sabrina Tedeschi
STAAD.Pro can design steel structures for a variety of US and International design standards : Available Steel Design Codes Designing Steel Structures - On Demand Training Learn how to design steel structures in STAAD.Pro CONNECT Edition. Download…
3 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
AS4100 in STAAD pro connect edition
Arash Nasr
The AS4100 version in the Staad Pro Connection Edition is 1998, is that correct? is there any way to update it to 2018 version?
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
What is the difference between mild steel and TOR steel?
Shree Ji Steel Corporation
Mild steel or threaded steel bar is steel that contains only a small amount of carbon and is strong and easily worked but not readily tempered or hardened whereas TOR steel only refers to cold treated bars.
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Designing Structures in RAM Elements
Sabrina Tedeschi
RAM Elements is a finite element-based general analysis program with an integrated design toolkit. In RAM Elements, you can design complex three dimensional structures or individual structural components. In the RAM Elements main application, a model…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Staad - Steel Design - Physical Members
RFreund
What is the latest on designing steel members in staad pro using AISC and physical members? It seems like you can design steel based on physical member properties for some codes, but not AISC, is that correct? Is this video current with the work flow…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Wrong Shear Capacity Calculation for Welded Built up Section as per IS 800-2007
Structural Engineer
1104.Model.std STAAD.Pro CONNECT Edition - Version 22.07.00.160 If we assign a rolled section from the table and assign STP parameter as 2, then shear capacity is calculated correctly by taking the depth of web x thickness of web (dtw). But when…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Illegal Framing Configuration - Beam 42
Carlos De Leon
I am getting an illegal framing configuration on Beam 42 on the lower level of my model. The data check rings up no warnings for the framing condition. However, when i run the beam design i get the error message for Beam 42 located on the diagonal A9…
Answered
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Steel Design Error in RAM Elements
Zachary Thompson
I have a project evaluating existing members that are, essentially, beams with overhangs. Both of them are built up sections. They are: Shape 1 Bottom plate = 1 5/8" x 34", Top plate = 2 1/8" x 26" (2) web members 1 1/2" thick x 32" tall. They are spaced…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Steel Design Parameters Get Lost When Physical Model Changes
Craig Brinck
I lost my steel design parameters somewhere along the way in one of my models. I think it happened when I was intersecting, deleting, and extending members.
over 1 year ago
RAM | STAAD | ADINA
STAAD.Pro
Member capacity as per AISC 360-16
Sellappan Karthick
Dear All, Please note the member capacity shown in the property dialog box is not as per the least capacity value calculated as per AISC 360-16. the design strength value showing in the beam property dialog box is not as per least design strength value…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Bracing System Configuration
Kalaiarasan A
Dear, I'm Requesting you to give some technical Clarification of the Bracing system is to be follow the Same Plane (Sidewall or Endwall), whether X-Bracing and Portal Bracing Allow to use the same Plane or not or need to do some Excises to keep the…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
base shear and lateral displacement value not matching with etab model
waqar fazi
Dear sir, Base shear gets by staad model is coming 269KN which is not matching with etab model (base shear 500kn) prepared by consultant.Also lateral displacement on siesmic cases is more in etab model than staad model.Can you explain why staad model…
over 1 year ago
RAM | STAAD | ADINA
RAM | STAAD Forum
THE VALUE OF MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4
Abhisek M
Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Steel Design Subarea: IS 800:2007 Original Author: Surojit Ghosh ***WARNING…
4 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
<
>