How do you find or change the friction method used in WaterGEMS and WaterCAD
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD Version(s): 08.11.xx.xx and higher Area: Modeling Problem How can you find or change the friction method used in WaterGEMS or WaterCAD? Solution The friction method can be found…
6 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Sharing Queries for use in other models
Jesse Dringoli
Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Other Original Author: Mark Pachlhofer, Bentley Technical…
1 month ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is there a way to model a rectangular pipe in WaterCAD, WaterGEMS or HAMMER?
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem Is there a way to model…
6 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Default Engineering Library missing
Jesse Dringoli
Product(s): SewerCAD, SewerGEMS, CivilStorm, StormCAD, WaterCAD, WaterGEMS, HAMMER, PondPack Version(s): CONNECT Edition, V8i Area: Libraries/Catalogs Problem The default engineering libraries appear to be missing…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is it possible to delete an element from one scenario, but retain it in another?
Jesse Dringoli
Applies To Product(s): WaterCAD, WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error Installing: "Error 1935. An error occurred during the installation of assembly"
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Installation Problem When installing a Bentley Hydraulics and Hydrology…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I reverse the profile view?
Scott Kampa
Product(s): SewerCAD, SewerGEMS, StormCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem How can i reverse the direction of profile view? Problem ID#: 41748 …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Pipes not merging when using Skelebrator with series pipe merging
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition Area: Modeling Problem When using the Skelebrator feature Series Pipe Merging, two pipes that appear to satisfy the parameters entered are not…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Controls to change pump speed
Jesse Dringoli
Applies To Product(s): WaterCAD, WaterGEMS, HAMMER, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem How can…
4 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Tank Low and High Alarm
Scott Kampa
Product(s): WaterGEMS, WaterCAD, Hammer Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem What is the purpose of the tank attributes "Use Low Alarm" and "Use High Alarm"? Solution If you set the "Use…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the purpose of the 'Accuracy' Calculation option?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS Version(s): V8i, CONNECT Edition Area: Calculation options Problem What is the purpose of the 'Accuracy' Calculation Option (listed under the Hydraulics section…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Negative values shown for Time in Time Series Field Data
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Layout and Data Input Problem Negative values are shown for Time (hours) in a Time Series Field Data graph: Solution…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Extracting Setup contents and prerequisites
Larry Abla
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Installation Problem In some cases, you may need to extract…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Can you run a VSP with a control node and logical controls at the same time?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: General Problem Can you run a VSP with a Control node and Logical Controls at the same time? Solution VSP Interactions with…
10 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the difference between Darcy-Weisbach roughness coefficients e and f, and Bed Roughness Ks or K?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem Difference between the coefficients e and f , when using the Darcy-Weisbach friction…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Configuration is incorrect" error after installation
Jesse Dringoli
Applies To Product(s): WaterCAD, WaterGEMS, HAMMER Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Other Original Author: Jesse Dringoli, Bentley Technical Support Group Problem When trying to…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I label my contours when using the AutoCAD platform?
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Problem How do I label my contours when using the AutoCAD platform? When generating a contour for my…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Software is running in disconnected mode
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, Hammer,StormCAD, SewerCAD, CivilStorm Version(s): 08.11.01.32 Area: Licensing Problem After checking out a license, I open the software and this message pops up: "Software…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using custom cells for element symbols in MicroStation Integrated mode
Yashodhan Joshi
Product(s): StormCAD, SewerCAD, SewerGEMS, CivilStorm, WaterGEMS, WaterCAD, HAMMER, PondPack Version(s): 10.XX.XX.XX, 08.11.XX.XX Environment: MicroStation Area: Other Problem How can I set up StormCAD (or one of…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Default license configuration not retaining setting
Larry Abla
Applies To Product(s): WaterCAD, WaterGEMS, StormCAD, SewerGEMS, CivilStorm, PondPack,, SewerCAD Version(s): CONNECT Edition, V8i Area: Licensing Problem When attempting to set the default license to…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is it possible to change the font for text in DXF backgrounds and annotations?
Sushma Choure
Product(s): WaterCAD, SewerGEMS, WaterGEMS, StormCAD, CivilStorm, SewerCAD, Hammer Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem Is it possible to change the font for text in DXF backgrounds and…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to find volume of water coming from a trace element?
wiki.author
Product(s): WaterGEMS, WaterCAD Version(s): V8i, CONNECT Edition Area: Output and reporting Problem How can I find the volume of water coming from an element that I set as the trace element in my pipes or my junctions…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Estimating a pump curve for a model
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): 08.11.XX.XX Area: Layout and Data Input Problem How do I develop a pump curve if the only known information is…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Displaying Shapefile Labels (Text) As a Background
Jesse Dringoli
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, StormCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem The labels that are in my shapefiles are not…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Calculating headloss through a hydrant lateral
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i (08.11.04.57 and later) Area: Calculations Problem How do WaterCAD and WaterGEMS calculate head losses through a hydrant lateral, when using the lateral option…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
>