Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
WaterGEMS
Reviewed2018
Annotations
ArcGIS
ArcMap
AutoCad
Background
CivilStorm
DXF
Element Symbology
FlowMaster
HAMMER
integration
LoadBuilder
Migrated
ModelBuilder
Modeling
PondPack
Reviewed2016
reviewed2017
Reviewed2019
Reviewed2020
SELECTsupport
SewerCAD
SewerGEMS
StormCAD
WaterCAD
How do I label my contours when using the AutoCAD platform?
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Problem How do I label my contours when using the AutoCAD platform? When generating a contour for my…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to manually check in a license
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack, CulvertMaster, FlowMaster Version(s): All Area: Licensing Original Author: Jesse Dringoli, Bentley…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do you create IF / THEN / ELSE statements using Formula-derived user data extensions?
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do each of the LoadBuilder methods work?
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Authors: Jesse Dringoli, Dan Iannicelli, Bentley Technical Support How do each…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Troubleshooting Controls in WaterCAD and WaterGEMS
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD Version(s): V8i, CONNECT Edition Area: Modeling Problem Controls do not appear to be working as expected. For example pumps (or other elements such as valves) do not appear to be…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Troubleshooting stability problems with PRVs or PSVs in parallel
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem When computing a model with…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the "Discharge Coefficient"?
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Data Input/Model Creation Original Author: Jesse Dringoli, Bentley Technical Support Group Problem…
4 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to create a Selection Set
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Modeling Problem How to create a selection set? Solution - Manual Creation Use the steps…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
General Pump Selection Process
Scott Kampa
Product(s): WaterGEMS, WaterCAD Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem What is the general process of using WaterCAD or WaterGEMS to select (size) a pump? Solution The general approach typically used…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Creating Custom Reports
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition Area: Output and Reporting Background Starting with the CONNECT Edition, you can now create custom reports that…
5 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Sharing Hydraulic Model Files on the OpenFlows | Hydraulics & Hydrology Forum
Larry Abla
Product(s): SewerGEMS, WaterGEMS, StormCAD, SewerCAD, CivilStorm, WaterCAD, PondPack, FlowMaster, CulvertMaster, OpenFlows Flood Version(s): Varies When posting on the OpenFlows (Haestad) | Hydraulics and Hydrology forum , providing…
2 months ago
About Bentley Communities
Communities Help Wiki
Quick Graph
Craig Calvin
Product(s): SewerGEMS, CivilStorm, SewerCAD, WaterGEMS, WaterCAD Version(s): 10.00.00.XX and later Area: Output and Reporting Introduction The quick graph feature allows you to quickly view a graph of a single element…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What is the difference between using ArcMap or ArcGIS Pro and using the integrated versions?
Scott Kampa
Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): CONNECT Edition, V8i Environment: ArcGIS Pro, ArcMap Area: Help and Documentation Problem What is the difference between using the WaterGEMS or SewerGEMS for…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Opening an existing hydraulic model when integrated with ArcMap or ArcGIS Pro
Jesse Dringoli
Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): CONNECT Edition, V8i Environment: ArcMap, ArcGIS Pro Area: Modeling The steps below will show add an existing hydraulic model while working in the ArcMap or ArcGIS…
7 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
The program hangs when opening a model or switching scenarios
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Performing clash detection of storm sewer and water hydraulic models
Yashodhan Joshi
Product(s): SewerCAD, SewerGEMS, WaterCAD, WaterGEMS, CivilStorm, StormCAD, HAMMER Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem: Is it possible to perform clash detection (otherwise known as Conflict Resolution…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Pump selection for a closed system
Sushma Choure
Product(s): WaterCAD, WaterGEMS Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem When designing a closed system with only demands downstream (no storage), how can the program help me select a pump? The system head…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Creating custom alerts or user notifications
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD Version(s): 10.XX.XX.XX, 08.11.05.XX+ Area: Modeling Problem How can I create custom alerts or user notifications? Video Solution In WaterGEMS and WaterCAD, Alerts can be configured…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Troubleshooting the Network Unbalanced or Cannot solve network hydraulic equations user notification
Luca Santos Billis
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem How can a user fix the WaterGEMS or WaterCAD error message " Network Unbalanced " or " Cannot solve network hydraulic equations ". "…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What does it mean if a pipe's flow is negative?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, CivilStorm, StormCAD, SewerCAD, PondPack Version(s): V8i, CONNECT Edition Area: Calculation Problem What does it mean if the calculated flow in a pipe is negative? Solution…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to register DAO360.dll or a dll file?
Jesse Dringoli
Product(s): SewerGEMS, SewerCAD, StormCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): 08.11.03.83 and 08.11.03.77 (for Storm and Sewer products); build 08.11.03.19, 08.11.03.17, and 08.11.03.16 (for Water products) Area: Installation…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I global edit the pipe material and have the roughness update?
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, StormCAD, CivilStorm, Hammer Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem How can I global edit the pipe material and have the roughness update…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to model a Combination Pressure Reducing Valve (PRV) and Pressure Sustaining Valve (PSV)
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem How to model a Combination Pressure Reducing Valve (PRV) and Pressure Sustaining Valve (PSV)? How do a model a PSV and PRV in series…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I model a backflow preventer?
Jesse Dringoli
Applies To Product(s): WaterGEMS, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem How can I model…
10 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
WaterGEMS for ArcGIS Pro and WaterGEMS for ArcMap FAQs
Jesse Dringoli
Product(s): WaterGEMS, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Training / videos Building a model from a Geodatabase with ModelBuilder in ArcMap Assigning Demands using LoadBuilder in ArcMap Assign elevations…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>