Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
WaterGEMS
Reviewed2018
Annotations
ArcGIS
ArcMap
AutoCad
Background
CivilStorm
FlowMaster
GPV
HAMMER
headloss
LoadBuilder
Migrated
ModelBuilder
Modeling
PondPack
Reviewed2016
reviewed2017
Reviewed2019
Reviewed2020
SELECTsupport
SewerCAD
SewerGEMS
Shapefile
StormCAD
WaterCAD
Software is running in disconnected mode
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, Hammer,StormCAD, SewerCAD, CivilStorm Version(s): 08.11.01.32 Area: Licensing Problem After checking out a license, I open the software and this message pops up: "Software…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
LoadBuilder Error: A very high number of Usage Types were found
Sushma Choure
Product(s): WaterGEMS, WaterCAD, SewerGEMS, Hammer, SewerCAD, CivilStorm Version(s): V8i, Connect Edition Area: Layout and Data Input Problem When trying to use LoadBuilder, the following error message occurs: "Calculations…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Comparing results between scenarios
Scott Kampa
Product(s): WaterGEMS,WaterCAD Version(s): V8i, CONNECT Edition Area: Output and Reporting Problem Is it possible to compare or visualize results between scenarios for example with annotations? Solution As of version…
9 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using custom cells for element symbols in MicroStation Integrated mode
Yashodhan Joshi
Product(s): StormCAD, SewerCAD, SewerGEMS, CivilStorm, WaterGEMS, WaterCAD, HAMMER, PondPack Version(s): 10.XX.XX.XX, 08.11.XX.XX Environment: MicroStation Area: Other Problem How can I set up StormCAD (or one of…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using the zero diameter option in Darwin Designer
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem Can Darwin Designer help design the number of parallel pipes to use or an optimal design layout? Solution The use of the zero…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
ArcMap Integration with limited functionality permissions
Scott Kampa
Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Problem At a minimum, what ArcMap features and functionality need to be enabled (given permission to) in order for integration with…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Integrating WaterGEMS, SewerGEMS and HAMMER with ArcGIS 10.3
Yashodhan Joshi
Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): 08.11.05.61+ (WaterGEMS & HAMMER) and 08.11.05.58+ (SewerGEMS) Area: Other Problem How can I integrate WaterGEMS, SewerGEMS or HAMMER with ArcGIS 10.3? Solution The Process…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is there a way to lock properties of elements?
Craig Calvin
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Modeling Problem Is there a way to lock the properties of elements so that…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Accounting for elevation difference in scaled pipe lengths
Scott Kampa
Product(s): WaterGEMS, Hammer, WaterCAD, SewerCAD, SewerGEMS, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Area: Modeling Problem How can I account for the elevation difference between two nodes in the calculation…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Darwin Calibrator Performance Improvement Tips for Large Models
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD Version(s): V8i, CONNECT Edition Area: Modeling, Data Input Original Author: sushma Choure, Bentley Technical Support Group Problem When calibrating…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error or bad results when using top filling tank option
Sushma Choure
Product(s): Bentley WaterGEMS, WaterCAD Version(s): V8i, Connect Edition Area: Other Problem After computing a model that uses the top filling option in one or more tanks, strange results are seen near the tank (such as a…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Creating Formula-Based User Data Extensions
Ankit Kulkarni
Product(s): WaterGEMS, WaterCAD, StormCAD, SewerCAD, SewerGEMS, CivilStorm, HAMMER, PondPack Version(s): CONNECT Edition, V8i SELECTseries 2 + Area: Calculations Overview The purpose of this technote is to briefly review the…
3 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How does the Pressure Sustaining Valve (PSV) work in WaterGEMS and WaterCAD?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Modeling How does the Pressure Sustaining Valve (PSV) work? Pressure Sustaining Valves (PSVs) throttle (ie. limit or restrict) flow to maintain a…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Changing element symbols in the AutoCAD platform
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): CONNECT Edition, V8i Environment: AutoCAD Area: Layout and Data Input Original Author…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Designing a sprinkler system in WaterCAD or WaterGEMS
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem Can I design sprinkler system using WaterGEMS or WaterCAD? I am trying to model a fire fighting system wherein a network of sprinklers…
11 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Calculating available flow at a hydrant
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Problem How can you calculate the actual flow available when opening a hydrant nozzle, accounting for losses based on the orifice diameter…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Products are listed multiple times in the Activation Status tab of the License Management Tool
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS,CivilStorm,SewerCAD, StormCAD, PondPack Version(s): 08.11.XX.XX and later (features vary) Area: Licensing Problem Products are listed multiple times in the Activation Status…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Copy and paste (import or export) tabular or Flextable data
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): 08.11.XX.XX and 10.00.00.XX Area: Layout and Data Input Problem How can tabular data (such as from a Flextable) be copied…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modifying and using Engineering Library Data
Scott Kampa
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, CivilStorm, StormCAD, SewerCAD, PondPack Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem How are Engineering Libraries used to add, modify and utilize…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Default license configuration not retaining setting
Larry Abla
Applies To Product(s): WaterCAD, WaterGEMS, StormCAD, SewerGEMS, CivilStorm, PondPack,, SewerCAD Version(s): CONNECT Edition, V8i Area: Licensing Problem When attempting to set the default license to…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is it possible to change the font for text in DXF backgrounds and annotations?
Sushma Choure
Product(s): WaterCAD, SewerGEMS, WaterGEMS, StormCAD, CivilStorm, SewerCAD, Hammer Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Layout and Data Input Problem Is it possible to change the font for text in DXF backgrounds and…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to find volume of water coming from a trace element?
wiki.author
Product(s): WaterGEMS, WaterCAD Version(s): V8i, CONNECT Edition Area: Output and reporting Problem How can I find the volume of water coming from an element that I set as the trace element in my pipes or my junctions…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Selecting hydraulic elements to view element properties in the ArcMap and ArcGIS Pro platforms
Scott Kampa
Applies To Product(s): WaterGEMS, SewerGEMS, HAMMER Version(s): CONNECT Edition, V8i Environment: ArcMap, ArcGIS Pro Area: Modeling Original Author: Akshaya Niraula, Bentley Technical Support…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Can WaterGEMS/CAD or HAMMER display elements in 3D?
Jesse Dringoli
Applies To Product(s): WaterGEMS, HAMMER, WaterCAD Version(s): 08.11.XX.XX and higher Area: Output and Reporting Problem Can WaterGEMS, WaterCAD or HAMMER display elements in 3D? Solution Typically…
7 hours ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Annotation or Color Coding not updating when scrolling through Time Browser or Changing Scenarios
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, HAMMER Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group …
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>