Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
WaterGEMS
Reviewed2019
ArcGIS
ArcMap
CivilStorm
Connection Client
Controls
CulvertMaster
error message
FlowMaster
HAMMER
installation
integration
licensing
MicroStation integration
Migrated
OpenFlows
PondPack
Reviewed2016
reviewed2017
Reviewed2018
Reviewed2020
SELECTsupport
SewerCAD
SewerGEMS
StormCAD
WaterCAD
WaterObjects.NET - How can I create a child scenario?
Jesse Dringoli
Product(s): WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack Version(s): V8 XM, V8i, CONNECT Edition Area: Modeling Problem How can I create a child scenario in a WaterObjects.NET project?…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using "Clock Time" and "Time From Start" Controls
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerCAD, WaterCAD Version(s): V8i, CONNECT Edition Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem What is the difference between a "Clock Time…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I make a PRV, PSV, FCV or TCV valve active after closing it with controls?
Jesse Dringoli
Applies To Product(s): WaterCAD, WaterGEMS Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Terry Foster, Bentley Technical Support Group Problem When using controls to open and close…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
OpenFlows software numerical solver theory
Sushma Choure
Applies To Product(s): CivilStorm, StormCAD, WaterCAD, WaterGEMS, SewerGEMS, SewerCAD, PondPack, Flowmaster, Culvertmaster Version(s): V8i, CONNECT Edition Area: Help and Documentation Original Author: …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling a submersible pump
Jesse Dringoli
Applies To Product(s): HAMMER, WaterGEMS, WaterCAD, SewerGEMS, SewerCAD Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Calibrating a model based on hydrant flow tests
Larry Abla
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem How can I calibrate a hydraulic model based on hydrant flow tests? Solution Hydrant flow test data can be used to calibrate…
6 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling hydropneumatic tanks in an EPS in WaterGEMS and WaterCAD
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD Version(s): V8i, CONNECT Edition Area: Layout and Data Input Original Author: Jesse Dringoli and Mark Pachlhofer, Bentley Technical Support Group Introduction This…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling a vertical turbine or multi-stage pump
Jesse Dringoli
Applies To Product(s): HAMMER Version(s): V8i, CONNECT Edition Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem How can a vertical turbine pump, or a…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using patterns to control pumps or reservoir HGL over time
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem How can I use patterns to change the pump speed over time (or turn it on/off based on time), or reservoir hydraulic…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Pressure dependent demands and negative pressure
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Calculations Problem How do pressure dependent demands (PDD) handle a situation where the pressure drops all the way to zero? I'm seeing an odd…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
WaterObjects.NET error: Could not load file or assembly
Jesse Dringoli
Product(s): WaterObjects.NET Version(s): 08.11.00.05 Area: Other Problem WO.NET error when running a sample model: Could not load file or assembly ... For example: Could not load file or assembly 'Haestad.SQLite…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Is WaterGEMS capable of modeling the formation of constituents in networks?
Scott Kampa
Applies To Product(s): WaterCAD, WaterGEMS Version(s): CONNECT Edition, V8k Area: Calculations Original Author: Scott Kampa, Bentley Technical Support Group Problem Description Is WaterGEMS/WaterCAD capable…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Troubleshooting problems with importing EPANET or EPASWMM files
Jesse Dringoli
Product(s): WaterGEMS, Hammer, WaterCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem When trying to import an EPANET .INP file into WaterGEMS or WaterCAD or an SWMM 5 .INP file…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
FATAL ERROR or Unhandled Exception when opening AutoCAD
Larry Abla
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, StormCAD, CivilStorm, PondPack Version(s): V8i, CONNECT Edition Area: Installation Problem When trying to open AutoCAD one of the following error message occurs…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Extracting Setup contents and prerequisites
Larry Abla
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Installation Problem In some cases, you may need to extract…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to duplicate FlexTables
Ankit Kulkarni
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): 08.11.XX.XX Area: Output and Reporting Problem Scenario 1 After creating a Project FlexTable you may decide that you want to…
3 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Filter FlexTable to only show active elements
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Output and Reporting Problem How do you filter the FlexTables so only active…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What file types are supported for background layers in the standalone platform?
Larry Abla
Product(s): WaterGEMS, WaterCAD, StormCAD, SewerCAD, SewerGEMS, CivilStorm, PondPack, HAMMER Version(s): 10.00.xx.xx, 08.11.xx.xx Area: Layout and Data Input Problem What file types are supported for background layers for the…
10 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Controlling license access to prevent unintended usage
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, WaterCAD, SewerCAD, FlowMaster, CulvertMaster Version(s): CONNECT Edition, V8i Area: Licensing Original Author: Mark Pachlhofer…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Open or import SewerCAD or SewerGEMS model in WaterCAD or WaterGEMS or vice-versa
Jesse Dringoli
Product(s): SewerCAD, WaterCAD, WaterGEMS Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem Is it possible to open or import a SewerCAD or SewerGEMS (.SWG / .SWR / .STSW) model in WaterCAD or…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I model a PRV with a bypass?
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Problem I have several PRV's in my model and most of the PRV's have a 2" loop (bypass). Should I try to model the bypass, or should it…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Results not matching assigned pattern
Jesse Dringoli
Product(s): WaterGEMS, SewerGEMS, WaterCAD, SewerCAD, StormCAD, CivilStorm, HAMMER Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Layout and Data Input Problem The pattern that I have assigned to my reservoir, demand or sanitary…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Darwin Designer to design pipes in WaterGEMS
Scott Kampa
Product(s): WaterGEMS Version(s): CONNECT Edition, V8i Area: Modeling Overview The purpose of this TechNote is to discuss common steps to design new pipe layouts and pipe rehabilitation projects using Darwin Designer in Bentley…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Darwin Calibrator
Luca Santos Billis
Product(s): WaterGEMS Version(s): CONNECT Edition, V8i Area: Modeling Overview The purpose of this technote is to explain how to calibrate a model using Darwin Calibrator in Bentley WaterGEMS. Additional information can be…
3 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error when computing: Reference to a deleted or inactive downstream pipe
Scott Kampa
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem After computing a…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
>