Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
WaterGEMS
reviewed2017
ArcGIS
ArcMap
AutoCad
CivilStorm
CulvertMaster
error
error message
FlowMaster
HAMMER
installation
licensing
Migrated
ModelBuilder
Modeling
PondPack
Reviewed2016
Reviewed2018
Reviewed2019
Reviewed2020
SELECTsupport
SewerCAD
SewerGEMS
StormCAD
User Notifications
WaterCAD
What files are needed to open a model in an OpenFlows product?
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, Hammer, SewerCAD, SewerGEMS, StormCAD, CivilStorm, PondPack, Culvertmaster, Flowmaster Version(s): CONNECT Edition, V8i Area: General Problem There are a number of different files in the folder…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Total pipe length in Pressure Pipe Inventory report different than in FlexTable
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Output and Reporting Problem When looking at the total length of pipe in the Pressure Pipe Inventory report, the value is different…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error when updating model with ModelBuilder: Index was outside the bounds of the array.
Yashodhan Joshi
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, StormCAD, HAMMER Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem When updating an existing model with ModelBuilder, the following error message is…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to convert a TCV GPV or PBV to an Isolation Valve using Skelebrator
Scott Kampa
Product(s): WaterGEMS, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Problem Numerous valve node elements (such as TCV, GPV or PBV) were created when constructing a model, which actually represent isolation valves…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Modeling a closed loop system
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD Version(s): All Area: Modeling Original Author: Thomas Walski and Jesse Dringoli, Bentley Systems Problem How can I model a closed loop system where…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I match the results I am getting from Darwin Calibrator in my model?
Scott Kampa
Applies To Product(s): WaterGEMS Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Problem You have done the manual run using Darwin Calibrator, but…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Adding Minor Losses to Pipes
Scott Kampa
Product(s): WaterCAD, WaterGEMS, Hammer Version(s): CONNECT Edition, V8i Area: Modeling Overview WaterCAD, WaterGEMS and HAMMER have the ability to model multiple minor losses in a single pipe. This TechNote explains how…
10 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to share a read-only version of a hydraulic model for anyone to view
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, Hammer, SewerGEMS, SewerCAD, CivilStorm, StormCAD, PondPack Version(s): CONNECT Edition, V8i Problem How can I share a hydraulic model with someone who does not have the OpenFlows software, so that…
1 month ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Run an Extended Period Simulation (EPS)
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Layout and Data Input Problem What is an Extended Period Simulation (EPS) and how can I run it? Solution When the variation of the…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Using Unit Loads and Extreme Flow Factors after a LoadBuilder run
Jesse Dringoli
Applies To Product(s): SewerCAD, SewerGEMS, WaterCAD, WaterGEMS Version(s): 08.11.XX.XX through 10.01.XX.XX Area: Modeling Original Author: Jesse Dringoli, Bentley Technical Support Group Problem…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Zero flow at all the junctions in the Fire flow Available column
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem After a Fire Flow analysis run, I get zero available fire flow at all the fireflow nodes. Solution This most often occurs…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Should I use the inside diameter or outside diameter for the "diameter" field for my pipes?
Jesse Dringoli
Product(s): WaterGEMS, HAMMER, WaterCAD, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD Version(s): All Area: Layout and Data Input Problem Should I use the inside diameter or outside diameter for the "diameter" field…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
OpenFlows Product Licensing FAQs and Troubleshooting
Jesse Dringoli
Product(s): StormCAD, SewerCAD, WaterCAD, CivilStorm, WaterGEMS, Hammer, PondPack, CulvertMaster, FlowMaster Version(s): V8 XM, V8i, CONNECT Edition Area: Licensing Below you will find a list of articles related to activating…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to add background aerial and road map images to your model
Luca Santos Billis
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CIvilStorm Version(s): 08.11.XX.XX and 10.XX.XX.XX Area: Layout and Data Input Problem Description How to attach background images or use aerial imagery…
15 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How to populate or update an existing model with GIS-IDs
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, PondPack, SewerCAD, HAMMER, WaterCAD Version(s): CONNECT Edition Area: Layout and Data Input Original Author: Jesse Dringoli, Mark Pachlhofer…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How do I enter time series field data and add it to my graph?
Jesse Dringoli
Applies To Product(s): WaterGEMS, SewerGEMS, CivilStorm, SewerCAD, WaterCAD Version(s): CONNECT Edition, V8i Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem How do I enter…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Do inactive elements count against the license count?
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): 10.XX.XX.XX Area: Licensing Problem Do inactive elements count against the license count? For instance…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Selecting multiple elements for a selection set
Scott Kampa
Applies To Product(s): WaterGEMS, WaterCAD, SewerGEMS, StormCAD, SewerCAD, CivilStorm, PondPack, HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group …
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Generating a log file for installation problem troubleshooting
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, StormCAD, CivilStorm, PondPack Version(s): CONNECT Edition, V8i Area: Installation Original Author: Jesse Dringoli, Bentley Technical…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Silent installation for Bentley OpenFlows Products
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, StormCAD, SewerCAD, CivilStorm, PondPack Version(s): Varies Area: Installation Index Silent Install Syntax Preventing Integration Patches .NET Framework CONNECTION Client…
8 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Intermediate Time Steps
Jesse Dringoli
Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS Version(s): V8 XM, V8i, CONNECT Edition Area: Modeling Original Author: Dan Iannicelli, Bentley Technical Support Group Problem…
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How are pumps handled in each OpenFlows product?
Jesse Dringoli
Product(s): WaterGEMS, SewerGEMS, CivilStorm, SewerCAD, StormCAD, HAMMER, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Problem How do pumps work in the hydraulics and hydrology products? Solution WaterCAD…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error opening existing project: "External component has thrown an exception"
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD Version(s): 08.11.xx.xx, 10.XX.XX.XX Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Error or Warning Message When…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Troubleshooting Water Age Results
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Water age results do not look right, or a strange or unexpected water age result is seen. Solution Water age results can…
5 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Error opening or creating project: Attempted to read or write protected memory
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): 08.11.XX.XX and 10.XX.XX.XX Area: Modeling Problem The following error is generated when opening or creating a model file…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
<
>