Browse By Tags

  • HI, everyone can anybody help me to create frame for storge oil tank without support (fixed, pinned, foundation,.............etc), because we have crane carry up this frame, so weight of the model will go above cuz crane, need strong designer to solve...

    STAAD SPACE START JOB INFORMATION ENGINEER DATE 19-Nov-22 END JOB INFORMATION INPUT WIDTH 79 UNIT MMS KN JOINT COORDINATES 12 14700 6850 0; 13 19450 6850 0; 14 27450 6850 0; 15 30101 6850 0; 16 14700 6850 4200; 17 19450 6850 4200; 18 27450 6850 4200;…
  • Design of Solid slab (Conventional slabs)

    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
  • Dummy beam

    Hello Everyone. I create a dummy beam with density=0 and E=0 (Figure.1) then I assign the beam (Figure.2) then Staad Error occurs( ***ERROR*** MATERIAL NAME MUST NOT CONTAIN ANY BLANK SPACE )(Figure.3), What is the solution?
  • Can I Reduce Development length of bars in the beam by using RCDC

    Hello Everyone How can I reduce the development length bars in the beam (Figure 1-1), I'm running to get a result like this beam (figure 2-1) Figure 1-1 Figure 2-1
  • how to get the loadings details in report????

    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
  • Bent Beam in Beam and Frame Design

    Hi, I have a question about the RAM Beam and Frame design. Do they complete each other or they are the replacement? The reason I am asking this question is the model that I have with Bent beam. The beam connects the top level to the mid level. If…
  • How to solve Detailing failure of Beam in Staad RCDC?

    I am working of a factory building, area of (119578*46422) sq.mm . Its holding Live Load of 130 psf . Columns 20 Nos. in long & 8 Nos.in short direction Dead Load is of Main wall(0.8353 ksf)+Partition wall(0.363 ksf)+Floor Finish(0.03 ksf)+Self…
  • Does STAAD design for CONCRETE SPECIAL MOMENT FRAME as per ACI 318M-11 ??

    Hi, 1. Does STAAD take into account the ductile detailing provisions of CHAPTER 21 of ACI 318M-11, while arriving at the reinforcement area and stirrup area ?? 3. If those provisions are available, how does STAAD identify a SMRF or IMRF or OMRF in…
  • RAM SS- Composite Beam Web Opening

    All, I read through the FAQ "Why are my composite beams being designed as non-composite members?' section but am still confused why RAM SS and SBeam both has po<5.6 limits for web penetrations, even for composite beams. I used Design Guide as an reference…
  • ACI 318 Incorrect Moment Capacity Concrete Beam

    Applies To Product: RAM Concrete First Affected Version: Found in Version: 15.05.00 Fixed in Version: Area: Design Issue #: 719833 Problem Description In some cases…
  • ACI 318 Shear Design of SMF Concrete Beams with Two-Way Decks

    Applies To Product: RAM Concrete First Affected Version: Found in Version: 15.03.00 Fixed in Version: Area: Design Issue #: 641214 Problem Description The design shear…
  • ACI 318 Design of Gravity Beams for Seismic Provisions

    Product(s): RAM Concrete Beam First Affected Version: Found in Version: 14.07.01.00 Fixed and Released in Version 15.04.00.00 Environment: N/A Area: Design Subarea: N/A …
  • Design shown after design errors

    Hi, I am getting the following errors when I run a Design All in the RAM Steel BEAM/Joist module. In cases where I can't get true composite action, I still want to specify the minimum amount of shear studs. What does the module show when I view the…