  • RE: steel frame building with tension cables

    For defining cables which would serve as braces in tension, it should be enough to specify these as MEMBER TENSION. You do not need to define these as cables as such. The cross section can be defined using the Define option within the Property - Whole…
  • steel frame building with tension cables

    Good day, I am currently modelling a steel structure that employs the use of tension cable for lateral bracing in addition to an eccentrically braced frame. I have a few queries as it relates to the specification for the cables, which I have listed…
  • RE: Calculating Deflection (P Delta Effects)

    Tension along a linear member does not impact perpendicular deflection in general finite element analysis. One would have to perform a full-blown cable analysis to see the effect of tension in reducing centenary drape. See Help - Contents - Section…
  • How to perform cable analysis?

    I have a structure that is X-braced with cables. I want to perform both types of analysis: Cable and Code Check for the columns and beams? I don't understand why, but I get slightly different results when I do just cable analysis vs. both (shown in attached…
  • RE: OpenPlant Modeler V8i SS5 Database files for Cable Trays

    Hello Curtis, Based on SR # 7000546031 raised, we have logged Enhancement # 562323. This will further gets evaluated by development & Product Management team. Submitting for your information please. -Regards | Rahul Kumar
  • RE: Error during cable analysis

    You were attempting to do a Nonlinear Cable Analysis but there was no pretension load defined which is essential. I added a pretension of 10KN ( you may change as needed). The bigger question is whether the nonlinear cable analysis is required or not…
  • STAAD.Pro Modeling Solutions

    Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Analytical Modeler Subarea: Modeling Solutions Original Author: Bentley Technical Support Group…
  • Continuous Cable with Intermediate Cable Supports

    Hi, I am trying to model a continuous cable with 13 intermediate vertical cable supports as well as 2 horizontal supports at the ends. The results don't seem to be making sense, as the supports at the end are only showing the initial tension and no…
  • RE: Best way to model a wire?

    Cables can be modeled using beam elements in STAAD.Pro. Following wiki has more information on how to assign cross sectional property to the cables http://communities.bentley.com/products/structural/structural_analysis___design/w/structural_analysis_and_design__wiki…
  • Error Message

    Every time I set a new object I get this error: Error Message: Object reference not set to an instance of an object TargetSite: System.String get Name() Declaring Type: ECT.ECAD.API.Rowltem Attributes: public virtual Member Type: Method
  • RE: Simple Steel Lifting Frame Analysis. Please Help!

    The following changes were made to the file *MEMBER TRUSS *1 3 12 was changed to MEMBER TRUSS 12 *SUPPORTS *5 FIXED BUT FX FZ MX MY MZ was changed to SUPPORTS 5 FIXED BUT MX MY MZ *PERFORM CABLE ANALYSIS BASIC SAGMINIMUM 0.7 STABILITY…
  • Analysis non-linear cable by using Preprocessor for Cable Stayed Bridge ?

    Hi All I'm using preprocessor for Cable Stayed Bridge for modeling cable sagging: in step 2 (6.6.5.3 at U.Guide): "Per-forming the analysis with this totally restrained system and the option Cable sagging selected will give the sagging line of all…
  • Cable Reports

    Hi, Just a question on producing cable reports. I have multiple different locations within my drawing. Is it possible to specify a distance between page locations so that when I produce a cable report it automatically shows how much cable is needed…
  • How to define a cable section

    Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Specifications Original Author: Sye Chakraborty, Bentley Technical…
  • RE: Runtime error 53

    Stuart I have put together a new Wiki document that should prove the quickest way of getting your existing custom cable data into the new installation.
  • Cable Laying Method-Single Layer

    I am looking for information on Cable Laying Method within BRCM, specifically, how do you route Single Layer cables? Does BRCM know because of the cable type (i.e. 1/0, 4/0, 500, etc) that is should be in single layer tray, or do we need to manually…
  • Featured LEARNing: On-demand QuickStart for Electrical Designers using Bentley Raceway and Cable Management

    QuickStart for Electrical Designers using Bentley Raceway and Cable Management In under two hours the five (5) courses in this learning path will show you how you can: Increase your productivity by creating a model and routing underground and…
  • Autorouting issues [BRCM 08.11.07.77]

    Automatic cable routing is consistently failing in the example projects and in our own. We have been able to get it working, but to do it we sometimes need to remove the equipment or cable completely from the project and re-import from the cable and equipment…
  • Family creation from importing an Excel spreadsheet

    I am looking for an easy way to create multiple families for various cable types (we have a lot to enter) without having to go through the family creation manager as this is a time consuming task. I was wonder if there a way of importing families from…
  • Cable command

    Hello everybody, I'm doing lifting analysis in STAAD-Pro V8i (the input file is attached). I've defined the slings as cable with command "MEMBER CABLE 4017 TO 4024 TENSION 0". After analysis, two of the slings are showing with huge compression, which…
  • Switch sides of a cable cross reference symbol

    Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Reports_Output Features Subarea: Wiring Diagram How to make devices appear on the opposite side…
  • Comparison of Cable Analysis between Staad Pro and Sap2000

    Please see the attached Staad model and Problem 7-001.pdf from Sap2000 verification example. The Sap2000 results are very close to those in the literature: Peyrot, A.H., and A.M. Goulois. 1979. "Analysis of Cable Structures". Computers and Structures…
  • RM Bridge - Cable Sagging for Cable Stayed Bridges

    Hi all, I have a doubt that I have already ask to the technical assistants, but I paste it here so it may help others too. I want to perform a Construction Stage Analysis of a cable stayed bridge. For a first shot (and for having something to compare…
  • Apply cable proprieties to wires on ‘wire layer’

    Promise SS3 on Autocad 2k8 Have a control panel and I am using different wire layers for the variouse type of wires. There are a few cable 'feeds' to the panel from distribution panels. (diferent drawing set). The cable feeding the panel is different…
  • Cable Numbers

    Hi All, Does anyone have an idea when if i add a cable symbol to a wire, and automatic wire number my drawing, the program still numbers the wire, even though i have to omit the wire with a cable box ticked? Thanks in Advance, Adam …