01. If the Service Level C coincident pressure P differs from the Peak Pressure (Level A and B), how can the Level C pressure be specified for this calculation in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
02. How to find out what SIF does AutoPIPE use for stress calculations in each point, for example in tees using ASME ND 1992+1993 addenda?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
03. Can you please explain what is zero moment and its involvement in ASME ND equation 10 code stress combination for thermal case?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Analsyis Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
04. Where should then Non-repeated Anchor Movement (e.g. Building Settlement) be accounted for if not in ASME ND Equation 10a in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
05. How to define building settlement for a Nuclear codes?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem: How to…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
06. Why does the calculated allowable for "ASME ND (2007) PRE-VERIFICATION STRESS REPORT", Eq 8, Load case = GR, not match the hand calculated value in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i Area: analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
AutoPIPE known issue - defect 135691 (8590)
Mike Dattilio
Applies To Product: AutoPIPE First Affected Version: 09.02.01 Found in Version: 09.02.01.07 Fixed and Released in Version: 09.03.00.08 Area: Calculations Severity: Critical …
over 4 years ago
AutoPIPE
AutoPIPE Wiki
AutoPIPE known issue - defect 135799 (8737)
Mike Dattilio
Applies To Product: AutoPIPE First Affected Version: 08.09.00 Found in Version: 09.02.01.07 Fixed and Released in Version: 09.03.00.08 Area: Calculations Severity: Critical …
over 4 years ago
AutoPIPE
AutoPIPE Wiki
AutoPIPE known issue - defect 134209 (7861)
Mike Dattilio
Applies To Product: AutoPIPE First Affected Version: 08.06.00 Found in Version: 09.00.00.08 Fixed and Released in Version: 09.01.01.02 Area: Calculations Severity: Critical …
over 4 years ago
AutoPIPE
AutoPIPE Wiki