  • Load Combination in Vertical Vessel Foundation

    While working on load combinations in Vertical Vessel foundation, extra load combinations are generated automatically whenever we re-open the file. Because of that Errors are showing like Soil Bearing Value (SBF) not to be zero. In Service load…
  • WATER GEMS UNIT DEMAND AND PEAK FACTOR

    Typically in a residential subdivision in Alabama we have been using a unit demand (per residential home) of 350 gpd (.24 gpm). I was always taught to use a peak factor between 2-3 so 2.5*.24 gpm=.60 gpm per residential home. Is this overly conservative…
  • existing Space frame steel roof - parameters problem (purpose-existing structure load modifications- we can not change existing members)

    STAAD SPACE START JOB INFORMATION ENGINEER DATE 10-Mar-22 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 3.09 0 0; 3 6.18 0 0; 4 9.27 0 0; 5 12.773 0 0; 6 15.863 0 0; 7 18.953 0 0; 8 22.043 0 0; 9 24.767 0 0; 11 1.545 1…
  • Import hydraulic model of SYNERGI (Software) in WaterGEMS.

    Hello, Want to known the hydraulic model generated in SYNERGI (Software) of water distribution system can be import ed in WaterGEMS . If yes let me know guys and what methodology should be adopted to import file, plz elaborate. Thanks and Regards …
  • How to assign haunch in staad pro?

    Actually i want to assign haunch properties near ridge and eave portion. How to assign haunch portion? Pls give ideas about that
  • How to get the multi-gable roof's wind load ?

    How to find out the multi gable roof wind load calculation?
  • I need all properties UC ratio in this small shed project

    V4.rar
  • organizations

    if i dont have an organization. or a member of a community .. how can i have the opportunity to have my license?
  • 量测土方量

    请问cc生成的模型里面有包括树木,沙堆,建筑垃圾,但是我只想量测建筑垃圾的体积,有没有什么好一点的解决方案呢
  • FYLD (DESIGN)

    HI SIR, I AM DESIGNING A STRUCTURE .wHEN I CHANGE YIELD STRENGTH FROM 243 MPA TO 355 MPA THERE IS NO EFFECT ON MY RESULTS. MY UTILIZATION RATIO SHOULD BE CHANGE BUT IT REMAINS SAME..pLEASE TEEL ME SOLUTION.?
  • how to split dgn file to multiple dgn file

    how can i spilt dgn file to many dgn files I have a dgn file and i want to spilt/divide to many dgn files using a shape element at the referance dgn file.
  • Export AutoCAD Civil 3D Pipe Network with Data to Microstations v8i ???

    I'm wanting to transfer a AutoCAD Civil 3d Pipe Network to Microstations.....Is this possible? If so, how do i go about getting the complex 3d drawing with data from one software to the other?