  • Design Gusset Plate Connection with Bracing Angle Above 70 Degrees

    I am designing gusset plate connections from a model I brought in from RAM SS. The frame from the model has bracing with and angle of ~75 degrees. As I understand, RAM Connect will not allow me to design the connection with bracing above 70 degrees. Is…
  • When using WEB SIDE PLATE design, how limcon check support member girder web yielding?

    When using WEB SIDE PLATE design, how limcon check support member girder web yielding? the detail design show that "informative check", which not giving failure warning if the forces is more than the capacity. Limcon has a value of capacity in the detail…
  • All users (including administrators), access via Smart client and Thick Client, cannot access system as it is Locked for Customizations.

    1. Open the APM database in SQL Server Management Studio 2. Locate and Select the Table "oq.connection_req" " table 3. Delete all the user records in this table. There only user in this table at this time should be the administrator who locked the…
  • Pdf Freigabe Berechtigungen

    Hallo, ich möchte eine pdf freigeben in MS V8i. Bei der Connect Edition habe ich den Haken gar nicht verfügbar. Bis jetzt ging das immer, nur jetzt kommt immer die Fehlermeldung: Ich muss dazu sagen. Es gibt nur mich in unserer Firma. Ich…
  • SSIS Connection Error with SSL Certificates

    Applies To Product(s): eB SSIS Version(s): 16.7.X Environment: N/A Area: SSIS Conection Subarea: Setup Original Author: Roberto Garcia, Bentley Product Support …
  • Automatic Sign in Error that says "Connection issues Could not connect Try Again"

    Did some research for errors on Bentley’s Website and went into the logs and found several errors that are listed below with how many times it occurred on 3/6/2019 between 8:54 & 9:23. ERROR - BUDDIClient - GetUrl() encountered an error: System…
  • Bentley Cloud Optioneering Visa Client Download

    Hello Everyone I need help with downloading Bentley Cloud Optioneering Visa Client .I have looked everywhere on Bentley's Connection centre to no avail.The end -user is disgruntled.Kindly assist
  • Apex connection design.

    How to design apex connection of a gable frame on connect edition? Any one can help me?
  • RAM Connection Elastic Weld Demand

    I am using RAM Connection for a base plate. The base plate has both uplift and shear concurrently. I was looking to see how the interaction of tension and shear was done on the weld and cannot figure out what RAM is doing to calculate the demand. …
  • CONNECTION Client Not Logging In

    Greetings, Yesterday and today, my CONNECTION Client (10.0.11.42) would not log in automatically, even though I have it set to automatically start up and then login when I use Bentley software. The Windows tray icon still showed a red X. When I went…
  • RAM Connection-Bolted Gusset Baseplate Connection Shear Lag Factor Error

    I'm currently getting a tension rupture failure at the brace-to-gusset weld in RAM Connection. My weld is 6" long, and I'm using an HSS6x6x3/16 brace. My hand calcs are giving me a U=0.625, however the program is incorrectly assuming a 3" long weld rather…
  • Back to back bolting for Web Angle is not working

    Product(s): ProSteel Version(s): CONNECT Edition (10.XX.00.XX) Environment: N/A Area: Global Settings/Options Subarea: Bolts, Connection Original Author: Sandip Kar, Bentley Technical Support…
  • Calculation of Znet for flexural rupture in RAM Connection

    I am checking a section for flexural rupture [AISC (9-4)] and I am coming up with a different net plastic section modulus than what RAM Connection shows. I believe RAM is taking the gross plastic section modulus and subtracting out the sections of the…
  • Can't Download LumenRT Content

    When I try to use/download LumenRT content, I get a download error that says "Unable to contact server. Please make sure your computer is connected to the internet." I am of course connected to the Internet. I have also tried reinstalling LumenRT with…
  • Pin connection between plate and edge beam

    Is there a facility in Staadpro to easily release the fixities bewteen the plate and edge beam to make the connections as pinned?
  • Cloning of connection or copying of connection from one location to multiple locations

    Product(s): ProSteel Version(s): CONNECT Edition Environment: N/A Area: Connection Manipulation Subarea: Cloning Original Author Sandip Kar, Bentley technical Support Group Overview We need to do connections…
  • Ram Connection and International codes

    Does Ram Connection support BS EN 1993-1-1:2005, AS 4100-1998, CSA S16-14 and now? If not, when is it going to support thees codes?
  • ram connection load combinations

    I completed a design in Ram SS and am now in the process of designing the connections. Everything converted into RAM connection but when the program designs the connections, the load combinations are all showing up as 0.00. Does anyone…
  • AutoPIPE CONNECT v.11.01.00.23 - Read Me file

    Applies To Product(s): AutoPIPE Version(s): CONNECT Area: Readme Date Logged & Current Version Sept 2017 11.01.00.23 Note: 1. Download Actual read-me file from AutoPIPE here 2. Select Link…
  • RAM Connection Seismic Provisions

    When checking the Seismic Provisions option in a CBB Connection the demand in the results output is 0 for all brace-gusset, gusset-beam, and gusset-column interface limit state checks. Is there a patch or expected fix for this?
  • RAM Connection Vertical Bracing

    Where is the option for "Additional Vertical Load" on the vertical brace member? This was previously an option and allowed the use of Case 2 of the Uniform Force Method to reduce shear demand on the beam connection?
  • Connection design from Staad loads

    Hello, Is there any facility in Staad to know all the algebraic sum of loads at a node for manua l designing of that connection?
  • Entdecken Sie wie Bentley Virtualität und Realität zusammenführt - CONNECTION Seminar 1. Juni in Frankfurt

    Liebe Bentley Anwender, wir laden Sie ganz herzlich ein zum Bentley CONNECTION Seminar am 1. Juni in Frankfurt. Lernen Sie, wie man eine umfassende Modellierungsumgebung erstellt, verwenden Sie Technologien zur Erfassung der realen Umgebung und automatisieren…
  • need to get the activate license

    hi.. i am unable to activate my AECOsim building designer v8i series 6 software ,can i get the activate license
  • How to Associate an OpenPlant PID Drawing with Another Project

    Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 Bit) Area: Database Subarea: N/A Original Author: Ron Plaisance, Bentley Product…