Free field boundary conditions for PLAXIS 2D: new improvements and recommendations for practical use
Micha van der Sloot
Application PLAXIS 2D Version PLAXIS CONNECT Edition V22 Update 2 PLAXIS 2D 2023.1 Date created 20 March 2023 Date modified 20 March 2023 Introduction One of the greatest challenges in dynamic finite element analysis…
7 months ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki
Compliant base and free field boundaries: check on input signal
Micha van der Sloot
Application PLAXIS 2D Version PLAXIS 2D AE Date created 23 July 2014 Date modified 23 July 2014 When using the free field and/or compliant base boundary condition we need to create so-called node pairs along the boundary…
over 3 years ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki
Fixed and Compliant base: what input motion is required?
Micha van der Sloot
Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D 2012 PLAXIS 3D AE Date created 23 July 2014 Date modified 23 July 2014 Fixed base The fixed base can be set up by selecting the “none” option from the Dynamic model…
over 3 years ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki
On the use of dynamic boundary conditions
Micha van der Sloot
Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D 2015 PLAXIS 3D AE Date created 23 July 2014 Date modified 23 July 2014 While setting up a dynamic model you may choose from the following dynamic boundary conditions…
over 3 years ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki
Memory usage in dynamic calculations
Micha van der Sloot
Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D PLAXIS 3D Date created 28 April 2014 Date modified 28 April 2014 A dynamic calculation will use more RAM memory than a static (Plastic) analysis of the same model…
over 3 years ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki
PLAXIS 3D Dynamic free field elements and its corners
Micha van der Sloot
Application PLAXIS 3D Issue status Solved First Affected Version PLAXIS 3D 2016 Found in Version PLAXIS 3D 2016 Fixed and Released in Version PLAXIS 3D CONNECT Edition V20 Issue # SW-31619 Date created …
over 3 years ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki
Plastic behaviour in free field elements in PLAXIS 3D AE.00 may lead to a severe divergence error
Micha van der Sloot
Application PLAXIS 3D Issue status ✔ Solved First Affected Version PLAXIS 3D AE.00 Found in Version PLAXIS 3D AE.00 Fixed and Released in Version PLAXIS 3D AE.01 Issue # 23608 Date created 13 May…
over 3 years ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki
Free field boundaries without compliant base bottom may turn into viscous boundaries
Micha van der Sloot
Application PLAXIS 2D Issue status ✔ Solved First Affected Version PLAXIS 2D AE.00 Found in Version PLAXIS 2D AE.00 Fixed and Released in Version PLAXIS 2D AE.02 Issue # 21525 Date created 11 June…
over 3 years ago
GeoStudio | PLAXIS
GeoStudio | PLAXIS Wiki