Browse By Tags

  • 04s. How to model a thrust via a flowing fluid (i.e. impulse-momentum change equation) to an AutoPIPE model?

    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Modeling Date Logged & Current Version Oct 2022 12.08.03.015 Problem: What's the best way to model thrust via a flowing fluid on Autopipe (Ie the impulse…
  • Fluid - PLAXIS UDSM

    Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D CONNECT Edition V21 PLAXIS 3D CONNECT Edition V21 Date created 25 January 2021 Date modified 25 January 2021 With the release of PLAXIS 2D/3D CONNECT Edition V21…
  • How can we define the fluid inside the pipe ?

    Hello, I am a beginner in Autopipe, I want to know the meaning of GR, and what is the benefit from making a static earthquake load and how can we define the fluid inside the pipe and I wanna make a model to calculate the example in this link...Thanks…
  • 04g. Model Fluid / Gas Density in AutoPIPE

    Comments, Questions, and Answers: Item #1: How to model fluid / gas density in AutoPIPE? Answer: Using AutoPIPE V8i 09.06.xx.xx, a user can input the contents density value on the Pipe Properties dialog screen / Input grid: Note: As mentioned…
  • 02u. "Fluid Transient" - AutoPIPE Load Case

    Comments, Questions, and Answers related to AutoPIPE's "Fluid Transient" Dialog screen Pressing OK button closes the dialog and the following report is displayed about the transient. This file is saved in the same folder as the model (example: W1…
  • Re: can WaterCAD be used for fluid other than water?

    Also, the fluids you analyze in WaterCAD should be Newtonian fluids (linear relationship between shear stress and shear strain rate). Wastewater with 2% solids should meet this criteria (you should satisfy yourself of this before running the calcs…