Civil 3D Shortcut Opens Plain AutoCAD Instead of Civil 3D
Jesse Dringoli
Product(s): WaterCAD WaterGEMS, HAMMER, SewerCAD, SewerGEMS, CivilStorm, StormCAD Version(s): 08.11.XX.XX and higher Environment: AutoCAD Civil3D Problem When opening the "<product name> For Autodesk Civil 3D" shortcut…
13 days ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I compare different profiles altogether?
Sushma Choure
Product(s): Bentley SewerGEMS, SewerCAD, StormCAD, CivilStorm Version(s): V8i, Connect Edition Area: Output and Reporting Problem I have multiple profiles for multiple scenarios that I want to compare, how can I do that?…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How can I reverse the profile view?
Scott Kampa
Product(s): SewerCAD, SewerGEMS, StormCAD, CivilStorm, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem How can i reverse the direction of profile view? Problem ID#: 41748 …
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
What Kind of Graphs Can I Create?
Sushma Choure
Product(s): SewerGEMS, StormCAD, SewerCAD, CivilStorm Version(s): 08.11.XX.XX, 10.XX.XX.XX Area: Output and Reports Problem What Kind of Graphs Can I Create and How Do I Create Them? Problem ID#: 78717 Solution In storm…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Can you integrate the hydraulics and hydrology products with a custom AutoCAD profile?
Scott Kampa
Product(s): WaterGEMS, WaterCAD, SewerGEMS, SewerCAD, CivilStorm, SewerCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Installation Problem Is it possible to integrate the hydraulics and hydrology products with a custom…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
StormCAD and SewerCAD (GVF Solvers) Flow Profile Calculations
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): V8i, CONNECT Edition Area: Calculations Problem Where can I find documentation on the computation scheme for the StormCAD (GVF-Rational solver) and SewerCAD (GVF-Convex…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Length Cannot be less than zero. Parameter name: length" when opening AutoCAD integrated mode
Sushma Choure
Product(s): WaterGEMS, SewerGEMS, CivilStorm, StormCAD, SewerCAD, HAMMER, WaterCAD Version(s): 08.11.XX.XX Environment: AutoCAD Problem When opening the AutoCAD integrated environment for a OpenFlows product (such as WaterCAD…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Profile not displaying results from the current scenario
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem In a steady state or EPS in WaterGEMS, WaterCAD or HAMMER, the profile is not displaying results from the…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Large drop in HGL not accounted for in HEC-22 energy loss results
Jesse Dringoli
Product(s): StormCAD, CivilStorm, SewerGEMS Version(s): 10.00.xx.xx, 08.11.xx.xx Area: Modeling Problem Why is there a large drop in the hydraulic grade line between a conduit and a node, when using the HEC-22 structure loss…
over 6 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
EGL OUT higher than EGL IN
Steve Van Saun
Hello, for some reason I am getting an EGL that drops down as you head upstream. I would expect the EGL to continue to climb as you move up the profile. The inflow at GI-3 is 0.95 cfs and the inflow at CB-4 is 1045 cfs, so not all that high. Also, the…
Answered
over 6 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Profile shows Hydraulic grade line below the ground elevation between two structures (Solution 500000086645)
Larry Abla
Applies To Product(s): StormCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Subarea: N\A Problem Profile shows HGL (Hydraulic grade line) below the ground…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
"Unable to read beyond the end of the stream" error when opening model or profile
Larry Abla
Product(s): StormCAD, CivilStorm, SewerGEMS, SewerCAD Version(s): 10.XX.XX.XX, 08.11.XX.XX Area: Modeling Problem When attempting to open a model or open a profile, an Error occurs, with the following details: System.IO.EndofStreamException…
9 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Hydraulic grade line in a profile is below the invert of a conduit or channel
Scott Kampa
Applies To Product(s): SewerGEMS, CivilStorm, StormCAD, SewerCAD Version(s): CONNECT Edition, V8i Area: Output and Results Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem …
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
StormCAD Profile plot showing multiple inverts (ie. laterals) at a structure
Randy Dueck
In StormCAD or SewerGEMS, is there any way to display the invert elevations of multiple pipes at say a junction or manhole on profile plot?
Answered
over 9 years ago
OpenFlows | Water Infrastructure