Browse By Tags

  • MS_SERVER cleared using PW

    Hi I am running MicroStation Connect updt. 16 and ProjectWise Explorer 10.00.03.434. I am having trouble connecting to a MS Access database when I have started MicroStation through ProjectWise. When I start MicroStation outside PW I can connect…
  • Why isent export without xref implemented yet?

    I've seen that there has been for several years been asked about how to export a singel dwg/ dxf without its xref's. Everytime this has been questioned, Bently has answared that this is not possible and never given any indications that its in the production…
  • ProjectWise Explorer Configuration - Toolbars

    Hi all, Is there a location where user PW client configurations are stored? In particular, toolbars enabled. Registry or config file? We would like to deploy a standard setup in our deployment package where Interface and View toolbars are enabled…
  • MicroStation CE not listed in ProjectWise install

    Hello All, I'll give you some overview information on what the specs before I dive into the meat of the inquiry: Version of ProjectWise: Client, 10.0.3.262 x86 MicroStation(s): SS4: 08.11.09.829 CONNECT: 10.13.1.1 Machines Primarily Used:…
  • ProjectWise /MicroStation Config

    OK it looks like PW is hijacking my site configuration. When MS launches from PW it does not call MS Config, it calls a 'tmp' file containing a hybrid configuration. I don't want this to happen, I want my site config to load. Any thoughts? …
  • Default open dialog paths

    I am supporting a user that is interested in having various load/open dialogs in ProjectWise-integrated MicroStation V8 and V8i open to specific paths. For example, when using the open file dialog, she would like it to start in the folder from which she…
  • ProjectWise/MS Office 2010 integration broken with latest SS4 refresh

    I've had issues with the latest version of ProjectWise SS4 (8.11.11.559) seemingly breaking integration with Microsoft Office 2010. I've seen the issue on both 32 and 64-Bit installations of Office. All of the workstations in question are running Windows…
  • ProjectWise and AutoPLANT Opening all Xrefs on each open

    There must be some sort of setting or hook that is causing ProjectWise to load all Xrefs every time we open models in the latest version. Even if you unload them they reload every time...
  • Configuration Debug - ProjectWise Explorer

    In MicroStation I can debug in the command line to determine configuration variable assignments with the '-debug=5' I would like to debug a file being opened from ProjectWise to determine the read/resolve variables. i know I can open the configuration…