Notificação do usuário: "Pump cannot deliver flow or head"
Luca Santos Billis
Aplica-se a Produto(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Versão(ões): CONNECT Edition, V8i Área: Cálculos Autor Original: Terry Foster, Grupo de Suporte Técnico da Bentley Problema…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki (Português)
How do i set up a known Pump and Hydropneumatic?
Jose Ramon Guzman Guzman
on the model that im doing, I will have to add and use a pump and a hydfropneumatic that are already on site. But I get confused when I neeed to add the definition of the pump curve and the hydropneumatic data. For the pump i have a Pedrollo Cp670 with…
Answered
over 4 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
How to develop a pump curve for a well pump when the only information I have is the well capacity(MGD)? [WaterGEMS]
Varenya Mehta
I have a model for a city(In WaterGEMS) with multiple Groundwater/Surface Water/Repump stations. Apparently, one of the Groundwater well pump has incorrect pump curve (head vs flow). I need to develop a new pump curve with the only info on hand being…
over 5 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Find if pump operates off of the pump curve during an automated fire flow scenario
Larry Abla
Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Output and Reporting Problem Is there a way to see if a pump is operating off the pump curve during an automated fire flow scenario? Solution …
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User Notification: "Pump cannot deliver flow or head"
Luca Santos Billis
Applies To Product(s): WaterGEMS, WaterCAD, HAMMER, SewerCAD, SewerGEMS, CivilStorm Version(s): CONNECT Edition, V8i Area: Calculations Original Author: Terry Foster, Bentley Technical Support Group Problem…
2 months ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
User notification "Pump exceeds the maximum operating point specified for the pump curve"
Jesse Dringoli
Applies To Product(s): WaterGEMS, HAMMER, WaterCAD Version(s): 08.11.XX.XX, 10.XX.XX.XX Original Author: Mark Pachlhofer, Bentley Technical Support Group Problem My pumps are operating at a much higher…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Estimating a pump curve for a model
Larry Abla
Applies To Product(s): WaterGEMS, WaterCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): 08.11.XX.XX Area: Layout and Data Input Problem How do I develop a pump curve if the only known information is…
over 2 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Re: Pump flow
Mal Sharkey
If the pump is 30 years old and you entered the original pump curve in the model, then that could explain also some differences (since the pump is not likely to be giving the same performance now as it did back when it was first installed). You…
over 15 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Pump Curve shape does not match data points.
Mal Sharkey
Hi Karl, Go to Analysis > Calculation Options and edit your existing Steady State / EPS calc option set(s). In the calc options you will find a section called Hydraulics, and in there is an option called "Use Linear Interpolation for Multipoint…
over 14 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum