20. Time History Results on symmetric model does not match when using AutoPIPE, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version Feb 2020 12.02.00.14 Problem: Per the given symmetric model (attached, original and one I created from scratch): …
over 1 year ago
AutoPIPE
AutoPIPE Wiki
19. Bending Stress reported by AutoPIPE is different from hand calculated values, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Code Stress Date Logged & Current Version Dec 2019 12.02.00.14 Problem: When plugging in the outputted values for in and out of plane bending moments, stress…
over 3 years ago
AutoPIPE
AutoPIPE Wiki
18. Would code stress results be the same regardless of which piping code was used in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Results Date Logged & Current Version May 2019 12.01.00.10 Problem: Would code stress results be the same regardless of which piping code was used in AutoPIPE…
over 4 years ago
AutoPIPE
AutoPIPE Wiki
02. AutoPIPE results does not seem to consider the pipe properties wall thickness with regards to Corrosion Allow. or Mill tolerance, only the Hoop Stress changed, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem: AutoPIPE…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
03. Comments, Questions, and Answers about AutoPIPE's Hoop code combination
Mike Dattilio
Comments, Questions, and Answers about AutoPIPE's Hoop code combination Item #1: Why is the ‘Max P’ load-case a default AutoPIPE Code combination? Item #2: AutoPIPE results does not seem to consider the pipe properties wall thickness with regards…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
15. Why is model over stress due to Harmonic loading in AutoPIPE's reports?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Reports Original Author: Bentley Technical Support Group Date Logged & Current Version May. 2017 11.00.00.22 Problem: Why is model over stress due…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
01.h.01 - Detail explanation of the Code Compliance settings in the Analysis Summary section of AutoPIPE's output report
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): 2004, XM, V8i, CONNECT; Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
"Code Compliance" sub-report using Results> Output Report in AutoPIPE
Mike Dattilio
Comments, Questions, and Answers: Note: see " Piping Code Calculations - AutoPIPE " wiki for more Code specific calculations and reporting errors Item #1: What is the meaning of: [xx%] [TR] w/sus. load margin Item #2: Why are Code stress results…
over 1 year ago
AutoPIPE
AutoPIPE Wiki
04. How to get stress results for gravity load-case only in AutoPIPE?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Reports Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015…
over 7 years ago
AutoPIPE
AutoPIPE Wiki
01. Why is the ‘Max P’ load-case a default AutoPIPE Code combination?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015…
over 7 years ago
AutoPIPE
AutoPIPE Wiki
01b. What does the [TR] mean in AutoPIPE's code compliance report?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Area: Reports Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015 09.06.01.10 Problem: What does…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
01a. What does the [xx%] mean in AutoPIPE's code compliance report?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Jan 2015…
over 5 years ago
AutoPIPE