  • PLZ SUGGEST THE REQUIED DESING PARAMETERS AND AND THERE VALUES WITH EXPLAINATION

    STAAD SPACE START JOB INFORMATION ENGINEER DATE 25-Sep-23 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 69 41.021 0 0; 70 80.516 0 0; 72 41.021 8.415 0; 74 80.516 8.415 0; 77 60.948 10.168 0; 87 47.6633 8.99933 0; 88 54.3057 9.58367…
  • non linear Cable analysis

    Hi, Can u explain anyone What is the meaning of REFORM 1 KGEOM 1 in non linear cable analysis what if i keep 0 instead of 1 " REFORM 1 KGEOM 0" Thanks in advance
  • Query Regarding Application of Floor Loading in STAAD

    Hi, I am analyzing G+2 Building structure. I have applied Floor load by Grouping Method ( Without the modelling of the Plate ). I am getting heavy reinforcement in beam. Kindly help me to find out the reason behind this. Also, Is this the correct…
  • STAAD's Displacement

    Is this a normal displacement in STAAD.Pro Connect Edition? I am designing a pedestrian footbridge and I happened to encounter this displacement in a certain load case?
  • Design of concrete column in anew version of staad

    hello sir, I have two questions 1-when we design concrete column in a new version of staad shows area steel only in report but in old version when we design concrete column and print report shows type of column(400x400 for example), and critical…
  • *** ERROR *** ABOVE COMMAND IS NOT RECOGNIZED. LINE IGNORED. anyone plz help me

    *** ERROR *** ABOVE COMMAND IS NOT RECOGNIZED. LINE IGNORED. i cant understand
  • Plate Stresses values are not coming same in two different models of Staad Pro.

    I have two models of staad pro in which one I have generated by importing a dfx file into it and other one is forwarded by client which origin I dont know that how he created the geometry of that model.Loading, dimension and plates thickness all are same…
  • in section wizard , while importing the section by general section , error pops up says " profile point for this shape will not be exported"

    I am using a square section by TATA STRACTRA one on top of another.
  • hi everyone, can anybody help me to solve this model because have error of the snow and seismic loads??

    STAAD SPACE START JOB INFORMATION ENGINEER DATE 30-Nov-22 END JOB INFORMATION INPUT WIDTH 79 UNIT MMS KN JOINT COORDINATES 55 468.544 16072.7 192.577; 73 507.061 16072.7 -1.061; 107 358.857 16072.7 356.735; 151 7030.99 14763.7 2911.01; 152 7609.76 14763…
  • Extreme Soft Storey and Floor Diaphragm

    Good morningEveryone, will you help me with this, we have a project of designing a 5storey building but have problems with having a soft storeys and floor diaphragms that nodes does not exist. May i ask for suggestion on how we can lessen it to make it…
  • STAAD ANALYSIS

    Hi Everyone! I'm having a hard time fixing my model. it has a warning saying WARNING-fx fy fz wind forces: I Can't correct it no matter what i do. Can Anyone help me out? Thanks a lot always. Here is the file 5488.FILE.std
  • STAAD Aluminum Design

    I am trying to design a aluminum frame. the error I am getting is " wrong strength parameter". I tried to input - Fy - 5040, Fu - 5472, Ry - 1.1, Rt - 1.1, Fcu - 5040. Why am I getting error ? Please share correct values or am I selecting wrong Aluminum…
  • Calculation of Stress Concentration Factors for Beam Modelled as Plate Section

    Dear All, I have modelled the BEAM (1000x300x20x30) TO BEAM (600x200x11x17) FLANGE CONNECTION using STAAD and now i am upto find the Stress Concentration Factors for the same. Attached summary shows the STAAD Model, Boundary Condition, Axial Forces…
  • Staad Purlin's design was all about failure.

    PEB warehouse structures Please, solve We have been trying to build a PEB staad.pro model of a warehouse for the past several days. We have set up all the IS standards of property and loading settings we know. However, the economic conclusion…
  • WALL OVER A SLAB

    How did know the exact coordinate of the partition wall?? please help me
  • *** ERROR *** ABOVE COMMAND IS NOT RECOGNIZED. LINE IGNORED.

    Please, someone can help me. One error says *** ERROR *** ABOVE COMMAND IS NOT RECOGNIZED. LINE IGNORED. don't know what to do. RCD 4 Storey.std
  • Staad.Pro - Seismic loads by response spectra

    Hi, I need help defining seismic loads by using the response spectra line graph. I add seismic periods and accelerations in the 'Load Case Details' section (attached image). I did not use the 'Definitions' section to consider seismic. My question is how…
  • Large rotational displacement in Node.

    PR-1_24072022.STD I applied Moment along Mx direction. due to that i found rotational displacement with large amount. Also note i have specie as Truss. Attached model for reference. if any mistake by me please suggest.
  • Regarding Lx parameter value.

    How to give the design parameter of Lx(lateral torsional buckling) For column member. In my case, The column height is 12m, Minor axis direction tied at each 3m. But major axis direction not tied. What is the Lx parameter value?
  • NO LOADING DEFINED FOR UBC LOAD. RUN TERMINATED.

    1. STAAD SPACE DXF IMPORT OF CAD FILE.DXF INPUT FILE: C:\Users\SHASHANK KUMAR\OneDrive\Desktop\structure.STD 2. START JOB INFORMATION 3. ENGINEER DATE 05-JUN-22 4. END JOB INFORMATION 5. INPUT WIDTH 79 6. UNIT METER KN 7. JOINT COORDINATES 8. 1 -0.5 0…
  • In Staad foundation, no design result is getting generated

    sabbir ahmed -static - 07.05.22.std SOMEONE PLEASE REPLY, Calculation sheet is not available as design has failed, why it is showing ? sabbir ahmed -static - 07.05.22_foundation.xml
  • Why I cant get to see beam and column design report and reinforcement detail on run analysis?

    Please go through the file and reply ASAP. I am waiting.Please go through the file and reply ASAP. I am waiting. sabbir ahmed -static.std
  • Wind load does not show

    As you can see here the wind load does not show on the rest of the Z+ building face i tried to play with the ranges but it does not work the part where it does not show is a cantilivar beam the left side of the photo down here
  • *** ERROR : "DEFINE" COMMANDS FOR LOAD GENERATION SHOULD BE PROVIDED BEFORE SPECIFYING PRIMARY LOAD CASES.

    Hi, Hopefully, you are doing well. could you please help me to solve this error? this is the code below. regards, DEFINE WIND LOAD TYPE 1 WIND -Z (WINDWARD WALL) <! STAAD PRO GENERATED DATA DO NOT MODIFY !!! ASCE-7-2010:PARAMS 137.000 KMPH 0…
  • I faced this error. please could you help me to solve this problem.

    this is the code STAAD SPACE START JOB INFORMATION ENGINEER DATE 09-Apr-22 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 0 12.085 0; 3 -1.05865e-015 0 5.763; 5 -2.11729e-015 0 11.526; 7 -3.17594e-015 0 17.289; 8 -3…