Browse By Tags

  • ISM is missing in the STAAD pro Physical Modeler

    Hello everyone Q1/ I am using the Staad Pro CE 22 update 7, the ISM is working fine in the analytical model but it is missed in the physical modeler, there is only iTwin service and does not work for me, as shown in the screen. After clicking it…
  • The Procees about Export and Import reinforce concrete design detailing(reinforce rebar) from STAAD.Pro to ProStructure using ISM

    Hello, everyone Let me ask about Exporting Reinforce Concrete rebar to Pro.Structure. relate with ( https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/39472/rebar-export-from-modules-and-ism-sync ) RAM Element…
  • Updated NDS/AWC wood design and Wood shear wall design

    Hi all, any chance to update the current wood design codes in Staad PRO & RAM Element? any chance to include wood shear wall in RAM Element? Thanks.
  • Analysis of Concrete Sandwiched between Two I-beams

    I have two I-beams with full depth concrete sandwiched between them modeled in RAM Elements. The concrete is only supported by the beams; I am getting a moment of 458 k-ft. per beam from RAM Elements, while manual calculation indicates the moment is about…
  • SIG Workshop - RAM: Leveraging Capabilities to Empower Your Workflows

    Title: SIG Workshop - RAM: Leveraging Capabilities to Empower Your Workflows Host/Presenter: Ann Marie Garko-Hill, Senior Manager – Application Engineering, Bentley Systems, Inc. Date/Title: 25 February 2021 at 01:00 P.M. EST Register Now! This…
  • Design of Solid slab (Conventional slabs)

    Hello Everyone For a while, I was using an Advanced Concrete Design (RCDC) for the design of a solid slab. Today I tried to learn the RAM concept for the slab designs but I saw a design of strips that had never seen before (When I was using RCDC and…
  • Mton/Cm to Kn/m

    How do I change Mton/Cm to Kn/m
  • Instability warning after applying Floor Diaphragm

    after applying floor diaphragm I am getting instability warning at mater joints please check my model and tell how to remove this warning 2061.major1 Wind.STD
  • SIG Virtual Workshop: STAAD - Understanding and Customizing the RAM Connection Database in STAAD.Pro

    SIG Workshop: STAAD - Understanding and Customizing the RAM Connection Database in STAAD.Pro Host: Jessica Portuese Presenter: Sabrina Tedeschi, Application Engineer – Structural, Bentley Systems, Inc. Date/Time: April 23 2020 01:00 P.M. EDT Register…
  • Working Remotely with RAM or STAAD

    Product(s): All RAM and STAAD applications Version(s): CONNECT Edition Environment: Any Area: Licensing, Installation We have assembled this wiki to help ensure a smooth transition of work from any location…
  • RAM Element_Wood Design Code

    I noticed that the wood design for RAM Elements is for NDS 2005 (for modules noticed the same), I think for STAAD Pro too, my license type is SEL, please let me know if updated NDS can be included in both programs soon? Regards..
  • UC Ratio problem

    warehouse.zip wind calculation also in that folder.... try to fix this probem guys
  • Diseño

    Buenas tardes compañeros, tengo una duda, utilizo staad.pro, para diseño de naves industriales, entrepisos, torres para tanques elevados, al igual que construcciones en concreto armado y todo con su respectiva zapata aislada o combinada, con análisis…
  • how to get the loadings details in report????

    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
  • UC Ratio problem

    Actually i need all members UC Ratio values. How to get all values???? Please guys guide me New folder (2).rar
  • Ram Connection Seismic Provisions Settings

    Applies To Product(s): RAM Connection (Ram Elements, Ram Steel, STAAD.Pro) Version(s): Various Area: Modeling; Design; General Where do I specify to consider seismic provisions in Connection Design? The…
  • how to reduce deflection????

  • Structural Synchronizer 10.03 Release Notes

    Release Date: October 10, 2018 Release Name: Structural Synchronizer CONNECT Edition Update 3 Release Version: 10.03.00.18 Download Instructions Structural Synchronizer can be downloaded at the link here , or from Bentley Cloud Services . After…
  • RAM Connection CONNECT Edition (v12.0.0) Release Notes

    RAM Connection CONNECT Edition v12.0.0 Release Notes – Updated March 2018 Enhancements : 1. Hollow structural section connections. Based on AISC 360-16 and the AISC Design Guide 24. Including: HSS-to-HSS Truss Connections: Y-T connections …
  • Structural Synchronizer 10.02.01 Release Notes

    Release Date: Coming Soon March 13, 2018 Release Name: Structural Synchronizer CONNECT Edition Update 2 Release Version: 10.02.01.147 Download Instructions Structural Synchronizer can be downloaded at the link here , or from Bentley Cloud Services…
  • Structural Synchronizer 10.02 Release Notes

    Release Date: December 13, 2017 Release Name: Structural Synchronizer CONNECT Edition Update 2 Release Version: 10.02.00.140 Download Instructions Structural Synchronizer can be downloaded at the link here , or from Bentley Cloud Services .…
  • RAM Connection

    Everything Needed for Steel Connection Design RAM Connection can check or design connections in seconds. Whether you design connections or need to check connections designed by the shop, RAM Connection is the software for you. In just one low-cost package…
  • P-Delta Analysis Using STAAD for Response Spectrum Load Cases

    Applies To Product(s): STAAD.Pro; Ram Elements Version(s): All Environment: N/A Area: Analysis Solutions Subarea: PDelta Analysis Original Author: Bentley Technical…
  • Is there a way to apply same design for multiple connections using RAM Connection in STAAD.Pro ?

    Hello the Engineers! Is there some way to apply same design for multiple connections unsing RAM Connection in STAAD.Pro ? For exemple, I want only one type of the beam-column connection in all frames. So I'll modify the connection parameters as I need…