Browse By Tags

  • RAM Frame and NBCC 2015 4.1.8.11 4)

    Hi, Based on NBCC 2015 4.1.8.11 4) single storey buildings with steel or wood deck as diaphragms can have a higher fundamental period compared to 4.1.8.11 3) as seen in the snap below. However, in the current RAM frame the Ta is only based on clause…
  • STAAD Webinar: Have no fear, Steel AND Concrete are here!

    It’s easier than ever before to take your project from analysis and design to automated drawing and documentation. Produce the bill of materials and gain instant insight into various design alternatives for the most cost-effective design. Please join…
  • UC Ratio problem

    warehouse.zip wind calculation also in that folder.... try to fix this probem guys
  • how to get the loadings details in report????

    I have got my report, but there is no loading details like dead load, Wind loads and all... In report settings i have added Loadings, but its not showing.... Wt to do???? i want to see other load details. How to get that details?
  • UC Ratio problem

    Actually i need all members UC Ratio values. How to get all values???? Please guys guide me New folder (2).rar
  • Barras armadas comprimidas Grupo IV y V

    Hola; Necesito saber si es posible generar barras según las define el reglamento CIRSOC 301, como Itipo Grupo IV y Grupo V en RAM, como se ven en la imagen del link. https://www.google.com.ar/url?sa=i&rct=j&q=&esrc=s&source=images&cd=&ved=2ahUKEwjp8…
  • Staad Pro - Critical moment calculation according to Eurocode 3

    Hi everyone! I am analysing a Channel section according to Eurocode 3 and I am finding it hard to understand how Staad calculates the critical Moment (Mcr) The critical moment I get from the program is different from the one I get from "Annex F of…
  • Staad Pro - AISC ASD steel design

    Hi everyone! Where can I find the expression for the parameters "FCZ", "FTZ", "FCY", and "FTY" in AISC ASD regulation? Thanks!
  • RE: shear area calculation

    Hi, I know the thread is quite old, but I have some questions about shear area in Staad.Pro. Please find below screen shot of Beam properties and the code check steel design result from STAAD.Pro. As you can see there is major difference in Ay…
  • Job opportunities in Qatar for engineers

    A prestigious public company in Qatar is hiring engineers : They urgently require the following professionals- MINIMUM 7 YEARS EXPERIENCE DESIGN DRAINAGE Foul Sewer Engineer Hydrologist Senior Planning Engineer Senior…
  • British Steel Design code BS 5950-1:2000

    Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Steel Design Codes Subarea: BS 5950-1:2000 Original Author: Bentley Technical Support Group …
  • Friday June 28th Insider Skills: RAM

    Click Here to see the full annoucement on our FREE Seminar series Insider skills.
  • Risa to Staad

    Our company recently went from Risa to STAAD, is there any way to import a RISA 3D file into STAAD other than the DXF feature? The dxf only imports the geometry and I would like to get the properties. I know you can go the other way, from STAAD to Risa…
  • Best Approach to Model and Design a Simple Four Sided Moment Frame Building in RAM SS

    I was wondering if there is any literature on the best way to approach the design of a simple four sided moment frame building using RAM Structural System? Thanks, Scott
  • [API CODE] ask : RATIO command

    dear all. i want to ask about the RATIO command in API code in Staad pro v8i. i use Staad Pro v8i SERIES 4. in AISC, the RATIO command means "Permissible ratio of actual to allowable stress". but in API, it says "Permissible ratio of applied loading…
  • large rotational displacement

    When running the STAAD, the result shows everything is right,. Structure is stable, no warning. Displacements are limited. BUT, I get some funny numbers for rotational displacement e.g. 533 degree & sometimes more. I checked releases. I believe they…
  • [STAAD PRO] Ask : API code design parameter

    Gents, today i'm working on pipe/tubular section in my model. to check the ratio in analysis, i'm using API code, but for non tubular section, i use AISC 9th Ed. however, i have some question regarding API code. (i use STAAD Pro v8i SELECT 4 20…
  • RAM - Steel Column design won't run.

    I have set up a model in RAM. It is A steel frame sat on an RC base. I have run the data check and there are no errors or warnings. I have run the steel beam design and it has given me section sizes. However, every time I try to run the steel…
  • Re: staad pro v8i (20.07.09.31) issue

    dear Shany. thank you for answering question 1. for question 3. i can't share the staad file due to company regulation. i'm so sorry. but i can show you my study staad for stair tower. this staad represent my problems. i check using AISC…
  • Why is Staad pro modifying input file after 2-3 analysis and/or closing/opening a file?

    Hello I am using Staad Pro v8i. I am designing a building with multiple frames and bays. I have added point loads at each node for every floor. After running fine for 2-3 times; Staad modifies the input file in such a way that the same load is applied…
  • RAM Connection - Beam Rupture Check

    I am using RAM Connection (standalone version 7.0). One of the connections I am designing for is a simple shear connection with clip angles welded to the supported beam and bolted to the supporing member/column. The beam in this case is not coped and…
  • Tapered Members

    Section 5.20.3 states that "f 1 (Depth of section at start node) should always be greater than f 3 (Depth of section at end node)." In the model I am working in, it makes more sense for me to define my members from left to right which results in some…