Browse By Tags

  • Street Works Product Update and Commitment to Street manager

    Please see email below from Lee Jackson, product manager. Dear User, I am writing to provide you with a product update on the Exor TMA Manager solution from Bentley Systems. We have been placing considerable investment into the heritage Exor brand…
  • Proximity Validation not working for some users

    Product(s): Exor TMA Noticing Manager Version(s): 04.07.00.00 Environment: N/A Area: Notices Subarea: N/A Problem Description TMA proximity validation isn't triggered for some users even…
  • Inspection Not Transmitted through EToN

    (8745 False) Applies To Product(s): Exor TMA Noticing Manager Version(s): 04.07.00.00 Environment: N/A Area: Inspections Subarea: N/A Original…
  • FRM-41830 Responding to Defective Apparatus Works

    Product(s): Exor TMA Noticing Manager Version(s): 04.05.10.44 Environment: N\A Area: Transactions Subarea: N\A Error or Warning Message When attempting to respond on a Works created by a…
  • Managed Service FTP - For EtoN5 Inspections

    Dear Manage service TMA user; With the implementation of EtoN6 all Inspections are sent via the Web Service like notices and permits making the EToN 5 Inspection batch process via FTP redundant. Bentley would like to switch off the AutoFTP process…
  • Opening the EXOR Application Directly to TMA1000 Works Form

    Applies To Product(s): Exor TMA Noticing Manager Version(s): All Environment: N/A Area: Alert Manager Subarea: N/A Original Author: Lee Jackson, Bentley Professional…
  • RE: Searching and reporting for Freedom of Information Requests

    Hi Allan, You can use almost any form in the exor product to query records and use the query count button to give a count of the records that would be returned for your query. If you need to produce an extract of data, then you could look at using an…
  • Interim Construction Method Warning Missing

    Applies To Product(s): Exor Noticing Manager Version(s): 04.05.10.02 Environment: N/A Area: Sites Defect Number: 98439 Original Author: Lee Jackson, Bentley Technical…
  • A consultation on the NSG Data Transfer Format version 8.1 has now been published

    The consultation on the National Street Gazetteer Data Transfer Format version 8.1 has now been published. The consultation seeks views on the proposed NSG DTF v 8.1. Views are invited on any aspect of the content, relating to the transfer format of Local…
  • New HAUC Advice Note 2014/02 Reinstatement Defects Not Causing Danger

    Hi, Please be aware that new guidance has been issued by HAUC for 'reinstatement defects not causing danger' prior to the release of the new Inspections Code of Practice. http://www.hauc-uk.org.uk/publication/47/ Thanks,
  • How To Respond To A Temporary Traffic Signal Application

    Applies To Product(s): Exor Noticing Manager Version(s): 04.05.10.02 Environment: N/A Area: Notices Original Author: Lee Jackson, Bentley Technical Support Group …
  • Invalid enumeration value 0

    Applies To Product(s): Exor Noticing Manager Version(s): 04.05.10.02 Environment: N/A Area: Works Original Author: Lee Jackson, Bentley Technical Support Group …
  • How to configure TMA Attachments

    Applies To Product(s): Exor Noticing Manager Version(s): 04.05.10.02 Environment: N/A Area: Attachment Original Author: Lee Jackson, Bentley Technical Support Group …
  • TMA 0311 Notice Name - Fix 12 available

    TMA Users please be aware that in EToN6 the name for a 0311 notice is now called a ‘Modified Application' where as previously it was called a ‘Variation Application’. Currently our application is still calling this notice type a ‘Variation Application…
  • Exor EToN 6 Seminars for TMA Users

    To our TMA Users: We will be running three seminars to cover the changes within version 4510 of Exor for EToN 6 at the following dates and locations: • Thursday 13th February - Gracechurch Street, London • Wednesday 19th February - Durham Council…
  • Unable To Issue A Notice To A Particular Recipient

    Product(s): Exor TMA Noticing Manager Version(s): n/a Environment: N/A Area: Notices Subarea: N/A Problem Description When sending notices an error is shown in the Fault Reason field next to…
  • The XML page cannot be displayed Cannot view XML input using XSL style sheet

    Applies To Product(s): Exor Noticing Manager Version(s): N/A Environment: N/A Area: Administration Subarea: N/A Original Author: Bentley Technical Support Group …
  • Some DCD Inspections Not Downloaded

    Applies To Product(s): Exor TMA Noticing Manager Version(s): N/A Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group …
  • Exor TMA EToN 6 Release

    Exor TMA version 4.5.10 has been released to the Download area of the SELECTservices website. Please see the Bentley Exor Support User Guide here: http://communities.bentley.com/products/assetwise/exor/m/mediagallery/247052.aspx for instructions if you…
  • Exor TMA1000 Unable to send Permit Response

    Exor TMA Manager version 04.05.00.00 TMA1000 When trying to send a permit response it is greyed out. I have tested this as the Admin login and it works but my login wont allow me to send a response. Steps to Reproduce: Open form TMA1000…
  • Standard Text Lost

    Post raised on behalf of user: We have inserted new standard text records for the TMA1001 Noticing Assistant form using the HIG4030 Standard Text Maintenance form. These records are shown in the standard text options in the TMA1001 form as expected…
  • Oracle Error

    Posted on behalf of user: User receives the following error messsage:- FRM - 93652: runtime process has terminated abnormally Amendment for completeness: Product = TMA Manager Forms = TMA1030 Query Works linking to TMA1000 Works
  • TMA Alert Manager

    Hi. I am trying to set up a new Triggered Event using the Alert Manager. The business have requested that I set up a new alert every time we set a Section 74 Over run charge. I have got as far as understanding that I need to create an alert on the…