Bentley Communities
Site
Search
User
Site
Search
User
Welcome
Products
Support
About
More
Cancel
Browse By Tags
All tags
tolerance
AutoPIPE
BArch
Bentley Building
Bentley WaterGEMS
connection
Continuous Foundation
converge
Convergence
copy does not work
defect
deviation
Exor Network Manager
import
Net
Offshore
PDELTA
pdelta analysis
PS Option
SET DISPLACEMENT TOLERANCE
SET PDELTA TOLERANCE
Translator
Unconservative
v8i
WaterCAD
WaterGEMS
OpenBuildings Designer - Clash Detection for Duplicate Elements
Kasia Wlosowicz
Clash Detection Tool can be used not only to find clashes between different levels, files and disciplines, but also within one file as a Self-Check and to detect duplicate elements. To perform a Self-Check: Go to Collaborate tab -> Clash Detection…
https://www.youtube.com/watch?v=7NOpAKaHlIA&ab_channel=BentleyOpenBuildings
View
Hide
2 days ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Blog
06. Confirm calculation of Flange dia with specified tolerance and corrosion settings using AutoPIPE Vessel
Tanaji Gaikwad
Example: In the flanges of this equipment, a 1 mm tolerance and 1 mm corrosion margin have been indicated, but in the calculations, the thickness "corroded dimensions" only subtracts 1 mm, for example, flange 20.04, nominal thickness 40 mm, calculation…
2 months ago
AutoPIPE
AutoPIPE Wiki
How To Use the SET FLOOR LOAD TOLERANCE Command to Ensure Proper Floor Load Generation
Sye
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Subarea: Loading Original Author: Phil Riegel, Bentley Technical Support Group …
9 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Regression Line from Rails Parameters
Dan Olausen, PE
I am unable to find documentation on what the 3 parameters accomplish in the Regression Line from Rails tool. Is this documented anywhere? The parameters I am interested in are: Minimum Distance Tolerance Maximum Distance Tolerance Maximum Deviation…
Answered
over 1 year ago
OpenRail
OpenRail Forum
Plate Thickness giving wrong value in PS Properties
Vyanktesh Nama
Product(s): ProSteel for AutoCAD Version(s): N/A Environment: N/A Area: Shape Placement Subarea: Properties Original Author Sandip Kar, Product Advantage Group Problem Description After placing Plate…
over 2 years ago
ProStructures
ProStructures Wiki
How to change the Tolerance of Rebar in ProConcrete
Vyanktesh Nama
Product(s): ProStructures CONNECT Edition Version(s): CONNECT Edition (Update-1) Environment: N/A Area: ProConcrete Subarea: Rebar/Concrete Code manager Original Author Sandip Kar, Bentley…
over 1 year ago
ProStructures
ProStructures Wiki
Incorrect Foundation Loads at Column-Brace Foundation Node due to Tolerance Issue
Seth Guthrie
Applies To Product: RAM Foundation First Affected Version: 15.04.00.00 Found in Version: 15.04.00.00 Fixed and Released in Version: 15.05.00.00 Area: Design Issue #: 695498 …
over 5 years ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Unexpected pipe connectivity after ModelBuilder import
Scott Kampa
Product(s): WaterCAD, WaterGEMS, HAMMER, StormCAD, SewerCAD, SewerGEMS, CivilStorm Version(s): V8i, CONNECT Edition Area: Layout and Data Input Problem When importing a polyline shapefile in Modelbuilder, the resulting pipes…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
W2143-37: Extremely high value for Displacement tolerance > 1000 detected in loadset warning message in AutoPIPE
Mike Dattilio
Applies To Product(s): AutoPIPE, Version(s): ALL Area: Warning message Original Author: Bentley Technical Support Group Problem: The following is displayed when performing…
over 2 years ago
AutoPIPE
AutoPIPE Wiki
11. When importing a PCf file into AutoPIPE, Status = "Incorrect Component Connection Tolerance Value", why and how to avoid?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Import Original Author: Bentley Technical Support Group Date Logged & Current Version April. 2015…
over 5 years ago
AutoPIPE
AutoPIPE Wiki
Tolerance for continuous foundations
Amber Hoey
When i add a tolerance so i can include 2 rows of columns for the continuous foundation more often than not when i get to the foundation design my foundation is not aligned along the grid i set it to - its no longer a straight line - it has become skewed…
over 6 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RE: Accudraw/Accusnap - Snap to point like acad
Andrew Bell
The help documentation should help to explain the basic operations for AccuSnap. Depending on the type of Snap mode that you have selected, when you start moving towards a snap point on the element a dotted cross hair will display. Then when you start…
over 7 years ago
MicroStation
MicroStation Forum
WARNING: Equilibrium Not Found Within Tolerance
Jason Forcier
Q: Why do I get WARNING: Equilibrium Not Found Within Tolerance when I computer righting arms with RARM? REV 7.02 A: MOSES rolls about the designated axis and finds equilibrium at each increment. Here equilibrium is weight and buoyancy forces. In order…
over 7 years ago
MAXSURF | MOSES | SACS | OpenWindPower
MAXSURF | MOSES | SACS | OpenWindPower - Wiki
Time tolerance setting in SCADAConnect Simulator
Jesse Dringoli
Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): Varies Environment: N\A Area: Output and Reporting The time tolerance setting in the new SCADAConnect…
over 3 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
How does STAAD. Pro check for convergence in a Pdelta Analysis
Modestas
Applies To Product(s): STAAD.Pro Version(s): All Environment: N/A Area: Analysis Solutions Subarea: PDelta Analysis Original Author: Bentley Technical Support Group…
5 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
Not able to copy a member or node or do a translational repeat
Modestas
Applies To Product(s): STAAD.Pro Version(s): ALL Environment: ALL Area: Modeling Solutions Subarea: Geometry Original Author: Sye Chakraborty, Bentley Technical Support…
5 months ago
RAM | STAAD | ADINA
RAM | STAAD | ADINA Wiki
AutoPlant BOM weight rounding/tolerance
PBA Projects
Good day I there a setting to change 61.25kg to 61kg when generating weight in a Bill of Materials on an isometric drawing? I am using AutoPlant Modeler and Isometrics for AutoCad 2015. Kind regards
Answered
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: P DELTA ANALYSIS
Sye
The answer to the query is posted at http://communities.bentley.com/products/structural/structural_analysis___design/w/structural_analysis_and_design__wiki/27979.how-does-staad-pro-check-for-convergence-in-a-pdelta-analysis
over 7 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
RE: Bentley Map Export dgn to shapefile - removes curves in alignment
Dan Weston
Stephanie, Try setting the ECSDK_GEOMETRY_STROKING_TOLERANCE variable in your Workspace Configuration settings. The value used represents the maximum distance between the actual element and the approximating line in master units. You can read…
over 7 years ago
OpenCities Map
OpenCities Map Forum
RE: Internal Error in PutNodeInList
Karl G
We have seen a few models recently that produced the same error. Very small coordinate discrepancies between beam ends and supporting columns and walls are associated with the problem. In some cases, the coordinate difference is less than 0.0001 in and…
over 7 years ago
RAM | STAAD | ADINA
RAM | STAAD Forum
Query, alert or formula UDX not working correctly with "=" (equals)
Sushma Choure
Product(s): Bentley WaterCAD, WaterGEMS Version(s): V8i, Connect Edition Area: Layout and data input Problem When using the equals sign (=) in a query, alert or "iif" statement in a formula derived user data extension, why…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
No network found within Tolerance error when creating a Defect
Fezan Khan
Applies To Product(s): Exor Core / Network / Document Manager Version(s): 4.X Environment: N/A Area: Locator Subarea: N/A Original Author: Bentley Technical Support…
over 8 years ago
ALIM | Exor
ALIM | Exor - Wiki
Tolerance setting for curved perforator in compound cell
Michael Arens
see: http://communities.bentley.com/other/old_site_member_blogs/bentley_employees/b/noel_pages_blog/archive/2009/08/08/round-holes-in-a-square-wall-creating-curved-perforators-in-bentley-architecture.aspx How on earth does a new user have to know this…
over 10 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon | Forum
Round Holes in a Square Wall: Creating Curved Perforators in Bentley Architecture
Noel Page
Did you ever feel like punching a hole in a wall? Bentley Architecture makes it easy... When you create compound cells in Bentley Architecture, you can define a perforator that will automatically create an opening in a linear form. Because…
over 14 years ago
Bentley Colleague Blogs
How, When, What, Why, BIM.