Air valve modeling example file
Jesse Dringoli
The model illustrates the use of the air valve element. Several scenarios depict various configurations. This file is for demonstration purposes only. Note: This model can be opened in HAMMER version 08.11.00.30 and above.
Air_Valve_Example.zip
over 14 years ago
Bentley Files
TSGWaterWasteWater
Surge valve example model
Jesse Dringoli
This example model illustrates the use of the surge valve element. It includes multiple scenarios, depicting various configurations.
Surge_Valve_Example.zip
over 14 years ago
Bentley Files
TSGWaterWasteWater
Valve Closure example
Jesse Dringoli
This example model illustrates different ways to model valve closure with a TCV. Advanced TCV closure modeling is not included. Note: This model can be opened in HAMMER version 08.11.00.30 and above.
TCV_Closure_Example.zip
over 14 years ago
Bentley Files
TSGWaterWasteWater
Modeling Reference - Hydropneumatic Tanks
Jesse Dringoli
Product(s): HAMMER Version(s): CONNECT Edition, V8i Area: Modeling Overview This TechNote explains how the Hydropneumatic Tank element works and its typical application in HAMMER. For information on modeling h ydropneumatic…
over 1 year ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Wiki
Re: hydropneumatic tank
Jesse Dringoli
Rasha, I'd recommend reading the below technote, which goes into detail on how a hydropneumatic tank works and what all the attributes mean: Modeling Reference - Hydropneumatic Tanks The latest version of HAMMER (08.11.01.32) includes s Hydropneumatic…
over 13 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
How to model pump trip and restart?
Roadie
In Hammer V8i is there any way to model a pump trip/stop followed by a start? thanks.
over 11 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Transient Analysis
Sumith
Could anybody explain how could analyse the transient behavior of a pipeline in pump start up operation with partially filled & completely with water using Bently Hammer product?. I am using Bently Hammer V8 XM edition. Thanks, Sumith
over 12 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Pump Inertia - relationship with pump failure & operational pattern
Jesse Dringoli
I concur with Ben. With the "Shut after time delay" transient pump type, the applied torque instantly drops to zero at the time specified in the "time delay until shutdown" field. The impeller is then subject to deceleration based on the pump inertia…
over 13 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Hammer Negative Pressure - Instability at Steady State
David Railsback
Hello, I am using Hammer V8i. I have a simple layout for a pump station transient model. A pump draws from a wet well, and discharges over a syphon into an effluent conduit. The discharge syphon creates a negative pressure at steady state. My transient…
over 10 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Hammer Pump Transient Properties
bwhite
Is there anyway to make a responsible assumption for the pump transient properties if accurate data is not available? I have a distribution system model that I've been asked to do some transient analysis for. The model has detailed pump curves but I don…
over 10 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Modeling Valve closure in Hammer
suminda
Hi, I am modeling a HDPE treated water pumping main to see the effects of a pump trip and a valve closure (at the end). I am planning on using a altitue valve and it is supposed to close when the tank is full and also another motor operated valve to…
over 11 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Cla-Val Control Valves in Water Hammer
Jesse Dringoli
Hello BWhite, I do not have experience with those exact valve models, but I can provide some tips. The settings for a surge valve are indeed adjustable, to allow you to customize the valve to match the characteristics of the actual valve you need…
over 10 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Modeling tanks inlets
Jesse Dringoli
Hello, For a steady state or EPS simulation, a top-feed tank is typically modeled by using a PSV on the upstream side. By setting the PSV to the top elevation, the HGL will be forced up to that elevation instead of the tank initial elevation.…
over 13 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Suction pipe full vacuum
Jesse Dringoli
Hello Velibor, Some of our other forum members can probably clarify this behavioir better, but I feel that it is likely 'real'. Without examining your network and results, it's hard to tell for sure, but most likely the pump station has a check…
over 14 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Distribution Sytem Wide Hammer and Transient Analysis of RPZ
bpeskin
I am attempting to set up a model to demonstrate how a RPZ (Reduced Pressure Principle Backflow Preventer) will respond to Hammer. For those unfamiliar with the operation of an RPZ, I have attached a document which outlines this very well. …
RPZ.pdf
View
Hide
over 14 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Control valve response to transient event
LWillnow
Is there a way to model the response of a control valve to a transient event beyond manually inputting the transient operational pattern? An example would be what happens to a PSV when the transient pressure drops below the pressure set point.
over 12 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: How should i enter data for air valves?
Jesse Dringoli
Hello Cesar, I assume you're referring to Bentley HAMMER V8i. When using an air valve, you must be careful to size it such that air pocket collapse doesn't cause worse pressures than without the valve at all. Animate your profile path in…
over 14 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Modeling pump startup against a closed valve in HAMMER
LWillnow
We are trying to model a pump startup scenario in HAMMER (v 8.11.03.17) with the pump starting 10 seconds into the simulation and the discharge valve starting to open up 15 seconds into the simulation. We followed the Tech Note for startup scenario but…
over 11 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Moment of Inertia Turbine Input - Hammer
Matt Baird
Hi I am trouble shooting a Hammer model of a hydro scheme which is producing unexpected results. I have some confusion around which inertia Hammer uses. For hydro generation applications inertia is usually given as WR2 or GD2, with GD2 being four times…
over 10 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Hammer - Modelling vertical pipes
Matt Baird
I am modelling a hydro scheme which features a vertical shaft directly at the intake. So lets says the intake is J1 at elevation 100m and drops to J2 at 50m by a 50 m length of pipe before completing a 90 degree bend to horizontal. Whe using the profile…
over 10 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Hammer Analysis in Raw Water Transmission System
bwhite
I'm trying to evaluate the need for surge protection at new well locations in a raw water transmission system. I have a network of 6 wells all pumping to the water treatment plant. I'm new to Water Hammer and surge analysis so I'm just looking for some…
over 10 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: orifice in surge tanks
Jesse Dringoli
Hello Inbarasan, I'm a bit unclear on some of what you said, but I'll try my best to address your questions: "...which is the effective shape in orifice?" The surge tank orifice is assumed to be circular, as you must enter a diameter. If the…
over 13 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Hammer Reservoir Wave Attentuation
Jesse Dringoli
Hello Ryan, When the valve closes, the flow is basically zero. However, the presence of a reservoir (which has a constant hydraulic grade during the transient simulation) may cause small flows in the pipe after the valve is closed. These small…
over 13 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: How should i enter data for air valves?
Jesse Dringoli
Why do you think the results are not real? I would recommend animating your profile path to see if air pocket collapse is occuring - this phenomenon can indeed cause a very high upsurge. I cannot say for sure if your data was entered correctly…
over 14 years ago
OpenFlows | Water Infrastructure
OpenFlows | Water Infrastructure Forum
Re: Modeling Backflow in TCV and FCV
Jesse Dringoli
I assume you're using Bentley HAMMER. When you use a TCV or FCV, a discharge coefficient is calculated based on the head loss through the valve in the initial conditions. This discharge coefficient can be seen in the results section of the valve…
over 13 years ago